Hearth and Home Technologies Crescent II Framing and Clearances, Selecting Appliance Location

Page 6

3 Framing and Clearances

NOTE:

Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY.

Illustrations/diagrams are not drawn to scale.

Actual installation may vary due to individual design preference.

A.Selecting Appliance Location

WARNING

Fire Risk

Provide adequate clearance:

Around air openings

To combustibles

For service access

Locate appliance away from traffic areas.

When selecting a location for your appliance it is important to consider the required clearances to walls (see Figure 3.1).

NOTE: For actual appliance dimensions refer to Sec- tion 16.

B

D

 

In addition to these framing dimensions, also reference the

 

 

 

following sections:

Clearances and Mantel Projections (Section 3.C and 3.D)

Vent Clearances and Framing (Section 6)

C

A

 

A

B

C

D

Inches

24-5/8

23-1/2

34-7/8

15-1/8

Millimeters

625

597

886

384

Figure 3.1 Framing Dimensions

6

Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05

Image 6
Contents Model Crescent What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents High Altitude Installations Glass SpecificationsBTU Specifications 1Listing and Code ApprovalsInspect Appliance and Components Design and Installation ConsiderationsGetting Started Tools and Supplies NeededFraming and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel Projections SpaceTermination Locations Vent Termination Minimum ClearancesAlcove Applications Vent Termination Minimum ClearancesUse of Elbows Vent Information and DiagramsVent Table Key Measuring StandardsOne Elbow Vent DiagramsTop Vent Horizontal Termination Two ElbowsTop Vent Horizontal Termination Three Elbows Min MaxTop Vent Vertical Termination No Elbow V1 = 45 ft Max .7mTop Vent Vertical Termination Three ElbowsCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration Framing Non-Combustible Wall PenetrationInstalling the Firestop Spacer Installing Attic ShieldVertical Penetration Framing Appliance Preparation Securing and Leveling the ApplianceAttaching Vent to the Firebox Assembly Installing Vent PipeAssembly of Vent Sections Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsDisassembly of Vent Sections Securing the Vent Sections Vertical SectionsHorizontal Sections Installing Heat Shield and Horizontal Termination Cap Installing the Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Installing Roof Flashing and Vertical Termination Cap Pipe see FigureAssembling and Installing Storm Collar 16 Assembling the Storm Collar Around the PipeGas Pressures Gas InformationFuel Conversions Gas Connection Pressure Natural Gas PropaneHigh Altitude Installations Optional Remote Control Requirements Recommendation for WireConnecting to the Appliance Electrical InformationAppliance will not operate unless properly grounded Heat Junction Box Installation Installing Flame Control Solenoid Natural Gas OnlyMantel Projections Facing RequirementsInside Fit Surround Accessories Appliance SetupClean the Appliance Remove Shipping MaterialsLog Set Assembly LOGS-Crescent Positioning the LogsSRV2083-185Final placement appearance Replacing Glass Assembly Glass AssemblyRemoving Glass Assembly Replacing Light BulbOperating Instructions Before Lighting ApplianceBefore operating this appliance have a qualified technician Lighting Appliance Final Inspection byIntellifire Ignition Frequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Intellifire Ignition SystemSymptom Possible Causes Corrective Actions Maintaining and Servicing Appliance Before servicingInspect Maintenance Tasks Appliance Dimension Diagram 16Reference MaterialsVent Components Diagrams PipeDVP-TRAP Series Not for use on this Model DVP ComponentsService Parts List Log Set Assembly with burner203 Crescent Limited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information

Crescent II specifications

Hearth and Home Technologies' Crescent II stands as a leading example of cutting-edge fireplace innovation, delivering both aesthetic appeal and efficient warmth to any home. Designed with a focus on user experience, the Crescent II combines modern design with state-of-the-art technology, making it an ideal choice for homeowners seeking both functionality and style in their heating solutions.

One of the standout features of the Crescent II is its sleek contemporary design. The large viewing area, framed by minimalistic lines, creates a striking focal point in any room, allowing homeowners to fully appreciate the mesmerizing dance of flames. Available in various sizes and finishes, the Crescent II can seamlessly integrate into diverse interior styles, from modern to traditional.

The Crescent II is equipped with advanced heating technologies, including a powerful airflow system that optimizes heat distribution throughout the space. This ensures that the warmth is evenly spread, eliminating cold spots that can diminish comfort levels. The unit operates with high efficiency, offering a thermal efficiency rating that meets and often exceeds industry standards, making it an environmentally friendly choice.

In addition to its heating capabilities, the Crescent II features a user-friendly interface, equipped with intuitive controls that make managing the fireplace a breeze. Homeowners can easily adjust the flame height and heat output, allowing for personalized comfort. Some models also come with optional smart technology, enabling remote control via smartphone apps for added convenience.

Another notable characteristic of the Crescent II is its commitment to safety. The unit includes safety features such as a secure glass front that remains cool to the touch, protecting users from burns. The fireplace is designed for venting options that reduce emissions and enhance indoor air quality, ensuring a safe and healthy home environment.

Maintenance is also simplified with the Crescent II. The design allows for easy access to components for cleaning and servicing, providing peace of mind that the fireplace will continue to perform optimally with minimal effort.

In summary, the Hearth and Home Technologies Crescent II is an exceptional fireplace that combines elegance, efficiency, and advanced technology. Its modern aesthetics, powerful heating capabilities, user-friendly controls, and commitment to safety make it a top choice for those looking to add a stylish and functional heating element to their home. With the Crescent II, homeowners can enjoy the warmth and ambiance of a fire while embracing convenience and modern living.