Hearth and Home Technologies Crescent II After Appliance is Lit, Frequently Asked Questions

Page 39

C. After Appliance is Lit

Initial Break-in Procedure

When you light the appliance, you may notice that it pro- duces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial three to four hour continuous burn on high followed by a second burn up to 12 hours to fully drive off any odor from paint and lubricants used in the manufacturing process. Condensation of the glass is normal.

NOTE: The appliance should be run three to four hours on the initial start-up. Turn it off and let it cool completely. Remove and clean the glass. Replace the glass and run the appliance for an additional 12 hours. This will help to cure the products used in the paint and logs.

During this break-in period it is recommended that some win- dows in the house be opened for air circulation. This will help avoid setting off smoke detectors, and help eliminate any odors associated with the appliance’s initial burning.

WARNING

Fire Risk.

High Temperatures.

Keep combustible household items away from appliance. Do NOT obstruct combustion and ventilation air.

Do NOT place combustible items on top of or in front of appliance.

Keep furniture, draperies away from appliance.

CAUTION

Prevent accidental appliance operation when not attended.

Unplug or remove batteries from remote control if absent or if appliance will not be used for an extended period of time.

Property damage possible from elevated temperatures.

CAUTION

Smoke and odors released during initial operation.

Open windows for air circulation.

Leave room during initial operation.

Smoke may set off smoke detectors.

Smoke and odors may be irritating to sensitive individuals.

WARNING

Fire Hazard.

Keep combustible materials, gasoline and other flammable vapors and liquids clear of appliance.

Do NOT store flammable materials in the appliance’s vicinity.

Do NOT use gasoline, lantern fuel, kerosene, charcoal lighter fluid or similar liquids in this appliance.

Combustible materials may ignite.

D. Frequently Asked Questions

ISSUE

SOLUTIONS

Condensation on the glass

This is a result of gas combustion and temperature variations. As the appliance

warms, this condensation will disappear.

 

 

 

Blue flames

This is a result of normal operation and the flames will begin to yellow as the

appliance is allowed to burn for 20 to 40 minutes.

 

 

 

 

When first operated, this appliance may release an odor for the first several hours.

Odor from appliance

This is caused by the curing of the paint and the burning off of any oils remaining

from manufacturing. Odor may also be released from finishing materials and

 

 

adhesives used around the fireplace.

 

This is a normal result of the curing process of the paint and logs. Glass should be

Film on the glass

cleaned within 3 to 4 hours of initial burning to remove deposits left by oils from the

manufacturing process. A non-abrasive cleaner such as gas fireplace glass cleaner

 

 

may be necessary. See your dealer.

 

 

 

Noise is caused by metal expanding and contracting as it heats up and cools down,

Metallic noise

similar to the sound produced by a furnace or heating duct. This noise does not affect

 

the operation or longevity of the fireplace.

 

 

Is it normal to see the pilot flame

In an Intellifire ignition system it is normal to see the pilot flame, but it should turn off

burn continually?

when ON/OFF is turned off. In a standing pilot system the pilot will always stay on.

 

 

Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05

39

Image 39
Contents What to do if you smell gas Model CrescentHomeowner Reference Information CongratulationsTable of Contents 1Listing and Code Approvals Glass SpecificationsBTU Specifications High Altitude InstallationsTools and Supplies Needed Design and Installation ConsiderationsGetting Started Inspect Appliance and ComponentsSelecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseSpace Mantel ProjectionsVent Termination Minimum Clearances Termination LocationsVent Termination Minimum Clearances Alcove ApplicationsMeasuring Standards Vent Information and DiagramsVent Table Key Use of ElbowsTwo Elbows Vent DiagramsTop Vent Horizontal Termination One ElbowMin Max Top Vent Horizontal Termination Three ElbowsV1 = 45 ft Max .7m Top Vent Vertical Termination No ElbowThree Elbows Top Vent Vertical TerminationNon-Combustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration Framing Combustible Wall PenetrationInstalling the Firestop Spacer Installing Attic ShieldVertical Penetration Framing Securing and Leveling the Appliance Appliance PreparationAssembling Pipe Sections Installing Vent PipeAssembly of Vent Sections Attaching Vent to the Firebox AssemblyAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsDisassembly of Vent Sections Securing the Vent Sections Vertical SectionsHorizontal Sections Installing Heat Shield and Horizontal Termination Cap Installing the Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Pipe see Figure Installing Roof Flashing and Vertical Termination Cap16 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarPressure Natural Gas Propane Gas InformationFuel Conversions Gas Connection Gas PressuresHigh Altitude Installations Electrical Information Recommendation for WireConnecting to the Appliance Optional Remote Control RequirementsAppliance will not operate unless properly grounded Heat Installing Flame Control Solenoid Natural Gas Only Junction Box InstallationFacing Requirements Mantel ProjectionsInside Fit Surround Remove Shipping Materials Appliance SetupClean the Appliance AccessoriesPositioning the Logs Log Set Assembly LOGS-CrescentSRV2083-185Final placement appearance Replacing Light Bulb Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyOperating Instructions Before Lighting ApplianceBefore operating this appliance have a qualified technician Lighting Appliance Final Inspection byIntellifire Ignition Frequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Intellifire Ignition System TroubleshootingSymptom Possible Causes Corrective Actions Before servicing Maintaining and Servicing ApplianceInspect Maintenance Tasks 16Reference Materials Appliance Dimension DiagramPipe Vent Components DiagramsDVP-TRAP Series DVP Components Not for use on this ModelService Parts List Log Set Assembly with burner203 Crescent Limited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyContact Information

Crescent II specifications

Hearth and Home Technologies' Crescent II stands as a leading example of cutting-edge fireplace innovation, delivering both aesthetic appeal and efficient warmth to any home. Designed with a focus on user experience, the Crescent II combines modern design with state-of-the-art technology, making it an ideal choice for homeowners seeking both functionality and style in their heating solutions.

One of the standout features of the Crescent II is its sleek contemporary design. The large viewing area, framed by minimalistic lines, creates a striking focal point in any room, allowing homeowners to fully appreciate the mesmerizing dance of flames. Available in various sizes and finishes, the Crescent II can seamlessly integrate into diverse interior styles, from modern to traditional.

The Crescent II is equipped with advanced heating technologies, including a powerful airflow system that optimizes heat distribution throughout the space. This ensures that the warmth is evenly spread, eliminating cold spots that can diminish comfort levels. The unit operates with high efficiency, offering a thermal efficiency rating that meets and often exceeds industry standards, making it an environmentally friendly choice.

In addition to its heating capabilities, the Crescent II features a user-friendly interface, equipped with intuitive controls that make managing the fireplace a breeze. Homeowners can easily adjust the flame height and heat output, allowing for personalized comfort. Some models also come with optional smart technology, enabling remote control via smartphone apps for added convenience.

Another notable characteristic of the Crescent II is its commitment to safety. The unit includes safety features such as a secure glass front that remains cool to the touch, protecting users from burns. The fireplace is designed for venting options that reduce emissions and enhance indoor air quality, ensuring a safe and healthy home environment.

Maintenance is also simplified with the Crescent II. The design allows for easy access to components for cleaning and servicing, providing peace of mind that the fireplace will continue to perform optimally with minimal effort.

In summary, the Hearth and Home Technologies Crescent II is an exceptional fireplace that combines elegance, efficiency, and advanced technology. Its modern aesthetics, powerful heating capabilities, user-friendly controls, and commitment to safety make it a top choice for those looking to add a stylish and functional heating element to their home. With the Crescent II, homeowners can enjoy the warmth and ambiance of a fire while embracing convenience and modern living.