Hearth and Home Technologies Crescent II owner manual

Page 49

C. Service Parts List

CRESCENT II

IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When order- ing, supply serial and model numbers to ensure correct service parts.

ITEM

DESCRIPTION

SERIAL #

PART NUMBER

 

 

 

 

1

Valve NG

 

750-500

 

 

 

 

1

Valve LP

 

593-501

 

 

 

 

2

Glass Door Assembly

 

GLA-CRESCENTII

 

 

 

 

3

Control Module

 

593-592

 

 

 

 

4

3V Adaptor Plug

 

593-593a

 

 

 

 

5

Regulator Assembly NG

 

2083-062

 

 

 

 

5

Regulator Assembly LP

 

2083-063

 

 

 

 

6

Circuit Board

 

2083-030

 

 

 

 

7

Pilot Assembly NG

 

2090-012

 

 

 

 

7

Pilot Assembly LP

 

2090-013

 

 

 

 

8

Glass, Light Box

 

SRV2083-135

 

 

 

 

9

Orange Film (Kapton)

 

2083-180

 

 

 

 

10

Junction Box

 

4021-013

 

 

 

 

11

4 Lead Wall Switch Wire

 

2083-031

12

Nailing Tab

 

2083-212

 

 

 

 

13

12V Adaptor

 

2083-022

 

 

 

 

14

Log Set Assembly with Burner

 

LOGS-CRESCENTII

 

 

 

 

15

Log #4

 

SRV2083-185

 

 

 

 

16

Bracket, Glass

 

2083-134

17

Gasket, Light Box

 

2083-132

18

Valve Bracket

 

2083-133

 

 

 

 

19

Flex Tube

 

2073-007

 

 

 

 

20

Light Bulb

 

See note

 

 

 

 

 

Hood

 

2083-208

 

Glass Latch

 

386-122A

 

 

 

 

 

Wire Assembly

 

593-590A

 

Flue Restrictor

 

2083-206

 

 

 

 

 

Solenoid - 110 Volt Hi/Lo (NG only)

 

HTI-17-006

 

 

 

 

 

Lava Rock Bag (1 lb.)

 

705-420

 

 

 

 

 

Teco-Sil

 

2083-790

 

 

 

 

 

Wall Switch and Cover Plate

 

4041-128

 

 

 

 

 

Burner Orifice NG (#52C)

 

582-852

 

 

 

 

 

Burner Orifice LP (#61C)

 

582-861

 

 

 

 

 

ACCESSORIES

 

 

 

NG Conversion - IPI

 

NGK-CRESCENTII

 

LP Conversion - IPI

 

LPK-CRESCENTII

 

Patch Kit

 

SRV-PACK

 

 

 

 

 

Remote Control Kit

 

RC-SMART-HNG

 

 

 

 

 

Remote Control Kit

 

SMART-STAT-HNG

 

 

 

 

Note: Replacement bulbs to be supplied by homeowner. Recommended replacement: Sylvania mini candelabra 75 watts.

Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05

49

Image 49
Contents What to do if you smell gas Model CrescentHomeowner Reference Information CongratulationsTable of Contents BTU Specifications Glass SpecificationsHigh Altitude Installations 1Listing and Code ApprovalsGetting Started Design and Installation ConsiderationsInspect Appliance and Components Tools and Supplies NeededSelecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseSpace Mantel ProjectionsVent Termination Minimum Clearances Termination LocationsVent Termination Minimum Clearances Alcove ApplicationsVent Table Key Vent Information and DiagramsUse of Elbows Measuring StandardsTop Vent Horizontal Termination Vent DiagramsOne Elbow Two ElbowsMin Max Top Vent Horizontal Termination Three ElbowsV1 = 45 ft Max .7m Top Vent Vertical Termination No ElbowThree Elbows Top Vent Vertical TerminationPipe Clearances to Combustibles Wall Penetration Framing Vent Clearances and FramingCombustible Wall Penetration Non-Combustible Wall PenetrationInstalling Attic Shield Installing the Firestop SpacerVertical Penetration Framing Securing and Leveling the Appliance Appliance PreparationAssembly of Vent Sections Installing Vent PipeAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsSecuring the Vent Sections Vertical Sections Disassembly of Vent SectionsHorizontal Sections Installing the Horizontal Termination Cap Installing Heat Shield and Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Pipe see Figure Installing Roof Flashing and Vertical Termination Cap16 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarFuel Conversions Gas Connection Gas InformationGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Connecting to the Appliance Recommendation for WireOptional Remote Control Requirements Electrical InformationAppliance will not operate unless properly grounded Heat Installing Flame Control Solenoid Natural Gas Only Junction Box InstallationFacing Requirements Mantel ProjectionsInside Fit Surround Clean the Appliance Appliance SetupAccessories Remove Shipping MaterialsPositioning the Logs Log Set Assembly LOGS-CrescentSRV2083-185Final placement appearance Removing Glass Assembly Glass AssemblyReplacing Glass Assembly Replacing Light BulbBefore Lighting Appliance Operating InstructionsBefore operating this appliance have a qualified technician Final Inspection by Lighting ApplianceIntellifire Ignition Initial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Intellifire Ignition System TroubleshootingSymptom Possible Causes Corrective Actions Before servicing Maintaining and Servicing ApplianceInspect Maintenance Tasks 16Reference Materials Appliance Dimension DiagramPipe Vent Components Diagrams DVP-TRAP Series DVP Components Not for use on this ModelLog Set Assembly with burner Service Parts List203 Crescent Limited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyContact Information