7 Electrical Information

A. Ignition System Wiring

This fireplace is equipped with an electronic ignition system which operates on a 6 volt system.

The batteries are located within the ignition module which is located within the external control box. A wiring diagram is shown in Figure 7.1.

The battery pack requires four AA batteries (not included). See Section 11.B for battery replacement.

WARNING

Shock Risk

Replace damaged wire with type 105° C rated wire.

Wire must have high temperature insulation.

CAUTION

Battery polarity must be correct or module damage will occur.

B. Remote Control

This fireplace is equipped with a remote control to operate the ignition system.

9 volt battery required.

Follow operating instructions included with remote control.

CAUTION

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

 

FLAME SPARKER/

 

 

SENSOR

VALVE

 

PILOT

 

 

IGNITION MODULE

REMOTE

 

CONTROL

 

6VDC

ANT.

 

 

ON/OFF

 

 

WALL SWITCH

 

 

IGNITION

 

 

MODULE

 

 

(6V)

 

BATTERY PORT

 

 

(4 AA BATTERIES)

 

 

 

THERMOCOUPLE

 

 

BLOCK

 

ON/OFF

(CONNECTED TO

 

BACK OF VALVE)

 

SWITCH

 

 

 

 

VALVE

 

PILOT GAS LINE

 

 

CONNECTED TO

 

 

BACK OF VALVE

 

Figure 7.1 Electronic Ignition Wiring Diagram

 

10

Heat & Glo Lifestyle Collection • Dakota 42-CE4036-915 Rev I • 1/07

 

Image 10
Contents What to do if you smell gas Hot glass will cause burnsCongratulations Table of Contents Getting Started Design and Installation ConsiderationsListing and Code Approvals Fireplace CertificationFire Risk Framing and ClearancesSelect Fireplace Location Fire Risk Odor RiskClearances Mantel ProjectionsFireplace Locations Fireplace Minimum ClearancesRemove Logs and Shipping Cover Fireplace PreparationSecuring and Leveling Fireplace Fire Risk Explosion Risk Gas InformationGas Pressure Requirements Gas Connection Fire Risk Explosion Risk Asphyxiation RiskElectrical Information Ignition System WiringRemote Control Shock RiskFinishing OverhangNon-combustible Facing Diagram Facing MaterialClean the Fireplace Fireplace SetupGrate Assembly Placement Left Side Log SRV723 front view 13 Front Right Log SRV724 front view Glass Assembly Placing Lava RockOperating Instructions Before Lighting FireplaceFor Your Safety Read Before Lighting Lighting Instructions Lighting the FireplaceIssue Solutions Frequently Asked QuestionsFire Risk High Temperatures After the Fireplace is LitMaintaining and Servicing the Fireplace Valve Access and Service WasherBattery Replacement Control Wire Box Access Panel Batteries Switch Cover PlateMaintenance and Service Tasks Inspect Maintenance TasksSymptom Possible Causes Corrective Actions TroubleshootingElectronic Ignition System Fireplace Dimension Diagram Reference MaterialsService Parts DAKOTA42-CE Series Service Parts ListDescription of Part Service Parts DAKOTA42-CE Series Conversion Kits SRV727 SRV720 SRV723 SRV722 SRV728 SRV724 SRV742 SRV740 # Description of Part This page intentionally left blank This page intentionally left blank This page intentionally left blank Warranty Heat & GLO Lifestyle Collection Limited 10 Year WarrantyDo Discardnot