C. Maintenance and Service Tasks:
Inspect |
| Maintenance Tasks | |
|
|
| |
| 1. | Inspect for scratches and nicks that can lead to breakage when exposed to heat. | |
Doors, surrounds and |
|
| |
2. | Verify no obstructions to airflow through the louvers. | ||
fronts | |||
|
| ||
| 3. | Verify proper clearance to combustible household objects is maintained. | |
|
|
| |
| 1. | Inspect glass panels for scratches and nicks that can lead to breakage when exposed to heat. | |
|
|
| |
| 2. | Confirm there is no damage to glass or glass frame. Replace as necessary. | |
Glass assembly and |
|
| |
| Verify that latches engage properly, clip studs are not stripped, and glass attachment components are intact and | ||
glass | 3. | ||
operating properly. Replace as necessary. | |||
| |||
|
|
| |
| 4. | Clean glass using a nonabrasive cleaner such as Brasso®. Replace glass assembly if severely coated with | |
| silicate deposits that cannot be removed. |
1.Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided.
Valve compartment and |
|
| |
|
| ||
firebox top | 2. | Remove any foreign objects. | |
|
|
| |
| 3. | Verify unobstructed air circulation. | |
|
|
| |
| 1. | Inspect for broken, damaged or missing logs. Replace as necessary. | |
Logs |
|
| |
2. | Verify correct log placement and no flame impingement causing sooting. Correct as necessary. | ||
| |||
|
|
| |
| 1. | Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as necessary. | |
Firebox |
|
| |
2. | Replace fireplace is firebox has been perforated. | ||
| |||
|
|
| |
| 1. | Verify burner is properly secured and aligned with pilot or igniter. | |
|
|
| |
| 2. | Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary. | |
|
|
| |
| 3. | Replace rockwool with new | |
|
|
| |
| 4. | Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay. | |
|
|
| |
Burner ignition and | 5. | Inspect for lifting or other flame problems. | |
|
| ||
operation | 6. | Verify air shutter is clear of dust and debris. | |
| |||
|
|
| |
| 7. | Inspect orifice for soot, dirt or corrosion. | |
|
|
| |
| 8. | Verify manifold and inlet pressures. Adjust regulator as required. | |
|
|
| |
| 9. | Inspect pilot flame strength. Clean or replace orifice as necessary. | |
|
|
| |
| 10. | Verify millivolt output. Replace as necessary. | |
|
|
| |
| 1. | Verify operation of remote. | |
|
|
| |
Remote controls | 2. | Replace battery in remote transmitters and batteries powering receivers. | |
|
|
| |
| 3. | If fireplace will not be used for a long period of time, verify batteries have been removed. |
Heat & Glo Lifestyle Collection • Dakota | 23 |