A. Valve Access and Service
•The gas valve can be accessed behind the cement refractory panel on the right side of the fireplace.
•Lift doors out and set aside. There is a washer under each door. Be careful not to lose the washers.
WASHER
Figure 11.1 Lift Out Doors
•Remove logs if access is necessary after installation is complete. See Section 9.C. Remove logs in reverse order of set up.
•Remove grate if access is necessary after installation is complete. (Refer to Section 9.B.)
•Remove two screws on side of pilot shield and remove shield.
Figure 11.2 Remove Pilot Shield
•Use a phillips screwdriver to remove the two screws securing the refractory retaining strip. Remove the refractory side panel and set aside.
Figure 11.3 Loosen Refractory Retaining Strip
•Remove the inside valve access panel by lifting it up and out.
Figure 11.4 Remove Valve Access Panel
•Use a phillips screwdriver to remove the exterior valve access panel (remove four screws).
Figure 11.5 Remove Exterior Valve Access Panel
•Loosen lower pressure tap screw before attaching manometer. Start up the fireplace to verify the pressure and adjust as necessary. Reverse these steps to reassemble before log positioning.
Note: Pressure tap screws must be
Figure 11.6 Connect Manometer