3 Framing and Clearances

Note:

Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY.

Illustrations/diagrams are not drawn to scale.

Actual installation may vary due to individual design preference.

A. Select Fireplace Location

When selecting a location for your fireplace it is important to consider the required clearances to walls (See Figure 3.1).

WARNING

Fire Risk

Provide adequate clearance:

Around air openings.

To combustibles.

For service access.

Locate fireplace away from traffic areas.

Note: For actual fireplace dimensions refer to Section 13.

1.47 M

G

F

C

2.08 M

D

 

Note: If this surface is inside the building’s warm air envelope...

B

A

F

E

...then this surface must be an exterior wall system.

G

F

C

D

E

Figure 3.1 Fireplace Locations

 

A

B

C

D

E

F

G

cm

62.9

61.3

121.9

124.5

1.6

1.3

3.8

WARNING

Fire Risk

Odor Risk

Install fireplace on hard metal or wood surfaces extending full width and depth of fireplace.

Do NOT install fireplace directly on carpeting, vinyl, tile or any combustible material other than wood.

WARNING

Fire Risk

Locate and install fireplace to all clearance specifications in manual.

Heat & Glo Lifestyle Collection • Dakota 42-CE4036-915 Rev I • 11/07

5

Image 5
Contents Hot glass will cause burns What to do if you smell gasCongratulations Table of Contents Listing and Code Approvals Design and Installation ConsiderationsGetting Started Fireplace CertificationSelect Fireplace Location Framing and ClearancesFire Risk Fire Risk Odor RiskMantel Projections ClearancesFireplace Minimum Clearances Fireplace LocationsSecuring and Leveling Fireplace Fireplace PreparationRemove Logs and Shipping Cover Gas Pressure Requirements Gas Connection Gas InformationFire Risk Explosion Risk Fire Risk Explosion Risk Asphyxiation RiskRemote Control Ignition System WiringElectrical Information Shock RiskOverhang FinishingFacing Material Non-combustible Facing DiagramGrate Assembly Placement Fireplace SetupClean the Fireplace Left Side Log SRV723 front view 13 Front Right Log SRV724 front view Placing Lava Rock Glass AssemblyBefore Lighting Fireplace Operating InstructionsLighting the Fireplace For Your Safety Read Before Lighting Lighting InstructionsFire Risk High Temperatures Frequently Asked QuestionsIssue Solutions After the Fireplace is LitMaintaining and Servicing the Fireplace Washer Valve Access and ServiceControl Wire Box Access Panel Batteries Switch Cover Plate Battery ReplacementInspect Maintenance Tasks Maintenance and Service TasksElectronic Ignition System TroubleshootingSymptom Possible Causes Corrective Actions Reference Materials Fireplace Dimension DiagramService Parts List Service Parts DAKOTA42-CE SeriesDescription of Part Service Parts DAKOTA42-CE Series Conversion Kits SRV727 SRV720 SRV723 SRV722 SRV728 SRV724 SRV742 SRV740 # Description of Part This page intentionally left blank This page intentionally left blank This page intentionally left blank Heat & GLO Lifestyle Collection Limited 10 Year Warranty WarrantyDo Discardnot