Hearth and Home Technologies Dakota 42-CE manual Gas Information, Fire Risk Explosion Risk

Page 9

6 Gas Information

A. Gas Pressure Requirements

B. Gas Connection

Pressure requirements for Heat & Glo gas fireplaces are shown in Table 1 below.

Two taps are provided on the outlet side of the gas control for a test gauge connection to measure the inlet and outlet pressures. These inlet and outlet pressure taps can be ac- cessed through the internal valve access panels as shown in Section 11: Maintaining and Servicing the Fireplace.

The fireplace and its individual shut-off valve must be dis- connected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 60 mbar.

If the fireplace must be isolated from the gas supply piping system by closing an individual shut-off valve, it must be of the handle-less type.

Note: Have the gas supply line installed in accordance with local building codes by a qualified installer approved and/or licensed as required by the locality.

Note: Before the first firing of the fireplace, the gas supply line should be purged of any trapped air.

Note: Consult local building regulations to properly size the gas supply line leading to the (Rp 1/2 in.) hook-up at the unit.

Incoming gas line should be piped into the valve compart- ment and connected to the ISO 7-Rp 1/2 (BSP Rp 1/2) threaded gas inlet connection on the manual shutoff valve.

Note: Gas line MUST be run from right side of fireplace.

WARNING

Fire Risk

Explosion Risk

High pressure will damage valve.

Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 60 mbar.

Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 60 mbar.

Table 1

WARNING

CHECK FOR GAS LEAKS

Fire Risk

Explosion Risk

Asphyxiation Risk

Check all fittings and connections.

Do not use open flame.

After the gas line installation is complete, all connections must be tightened and checked for leaks with a commercially available, non-corrosive leak check solution. Be sure to rinse off all leak check solution following testing.

Fittings and connections may have loosened during shipping and handling.

 

Natural Gas

Propane

Butane

Natural Gas

 

(G20)

(G31)

(G30)

(G25)

Inlet Pressure

20mbar

37 or 50mbar

30 or 50mbar

25mbar

 

 

 

 

 

Manifold Pressure

4-8.7 mbar

24mbar

24mbar

8.7mbar

 

 

 

 

 

 

 

 

 

Gas Rate

1.68

m3 h

.62

m3 h

.42

m3 h

1.68

m3 h

 

/

/

/

/

Max.Input (NETCV)

16.5 kW

15.0 kW

13.7kW

14.0 kW

 

 

 

 

 

Burner Injector

DMS 25

DMS 44

DMS 46

DMS 25

 

 

 

 

 

Pilot Injector

51

30

30

51

 

 

 

 

 

 

 

 

 

Heat & Glo Lifestyle Collection • Dakota 42-CE4036-915 Rev I • 11/07

9

Image 9
Contents Hot glass will cause burns What to do if you smell gasCongratulations Table of Contents Listing and Code Approvals Design and Installation ConsiderationsGetting Started Fireplace CertificationSelect Fireplace Location Framing and ClearancesFire Risk Fire Risk Odor RiskMantel Projections ClearancesFireplace Minimum Clearances Fireplace LocationsFireplace Preparation Remove Logs and Shipping CoverSecuring and Leveling Fireplace Gas Pressure Requirements Gas Connection Gas InformationFire Risk Explosion Risk Fire Risk Explosion Risk Asphyxiation RiskRemote Control Ignition System WiringElectrical Information Shock RiskOverhang FinishingFacing Material Non-combustible Facing DiagramFireplace Setup Clean the FireplaceGrate Assembly Placement Left Side Log SRV723 front view 13 Front Right Log SRV724 front view Placing Lava Rock Glass AssemblyBefore Lighting Fireplace Operating InstructionsLighting the Fireplace For Your Safety Read Before Lighting Lighting InstructionsFire Risk High Temperatures Frequently Asked QuestionsIssue Solutions After the Fireplace is LitMaintaining and Servicing the Fireplace Washer Valve Access and ServiceControl Wire Box Access Panel Batteries Switch Cover Plate Battery ReplacementInspect Maintenance Tasks Maintenance and Service TasksTroubleshooting Symptom Possible Causes Corrective ActionsElectronic Ignition System Reference Materials Fireplace Dimension DiagramService Parts List Service Parts DAKOTA42-CE SeriesDescription of Part Service Parts DAKOTA42-CE Series Conversion Kits SRV727 SRV720 SRV723 SRV722 SRV728 SRV724 SRV742 SRV740 # Description of Part This page intentionally left blank This page intentionally left blank This page intentionally left blank Heat & GLO Lifestyle Collection Limited 10 Year Warranty WarrantyDo Discardnot