Broan 42H-B, 42-B owner manual Valve Service and Replacement, Tools Required

Page 24

A. Valve Service and Replacement

Tools Required

Phillips screwdriver

7/16 in., 5/8 in., 13/16 in., 15/16 in. wrenches

Figure 12.1 Tools Required

The valve can be accessed through the valve access panel on the right side of the fireplace.

Lift doors out and set aside.

Remove grate and pilot shield (see Figure 6.2).

Figure 12.2 Lift Out Doors

Use a phillips screwdriver to remove the right refractory by removing the two screws securing the refractory retaining strip. Remove the refractory side panel and set aside.

Remove the inside valve access panel by lifting it up and out.

Figure 12.4 Remove Valve Access Panel

Using a phillips screwdriver remove the exterior valve access panel.

Figure 12.5 Remove Exterior Valve Access Panel

Turn the gas ball valve off and disconnect the gas line after the ball valve by loosening the flare nut using a 13/16 in. and a 15/16 in. wrench.

Figure 12.6 Turn off Gas Valve

Figure 12.3 Loosen Refractory Retaining Strip

24

Heat & Glo LifeStyle Collection • Dakota 42-B/Dakota 42H-B4036-909 Rev D • 08/06

Image 24
Contents This appliance must be installed outside What to do if you smell gasCongratulations Listing Label Information/LocationTable of Contents High Altitude Installations Listing and Code ApprovalsAppliance Certification Glass SpecificationsDesign and Installation Considerations Getting Started¨ Moisture Resistance Tools and Supplies NeededFraming and Clearances Select Appliance LocationFire Risk Fire Risk Odor RiskClearances Mantel ProjectionsTermination Locations Vent Termination Minimum ClearancesAppliance Preparation Remove Logs and Shipping CoverSecuring and Leveling Appliance Gas Information Fuel Conversion Gas ConnectionGas Pressure Fire Risk Explosion RiskFire Risk Explosion Risk Asphyxiation Risk Valve Access Lift Out DoorsRecommendation for Wire Intellifire Ignition System Wiring Connecting to the ApplianceElectrical Information Shock Risk Explosion RiskFinishing FireplaceNoncombustible Facing Diagram Facing MaterialAppliance Setup Clean the ApplianceGrate Assembly Placement Positioning the LogsFront Left Log SRV722 Glass Assembly Placing Lava RockOperating Instructions Before Lighting ApplianceFire Risk Burn Risk For Your Safety Read Before Lighting Lighting Instructions Lighting the Appliance Frequently Asked Questions Fire Risk High Temperatures Issue Solutions After the Appliance is LitTroubleshooting Symptom Possible Causes Corrective ActionsIntellifire Ignition System Maintaining and Servicing the Appliance Valve Service and Replacement Tools RequiredGround Wire Maintenance and Service Tasks Inspect Maintenance TasksAppliance Dimension Diagram Reference Materials¨ B. Service Parts List DAKOTA42-B SeriesDescription of Part Replaced by SRV4036-260 Pre Serial #OD9288 Battery Pack 593-594A Also availableSRV727 SRV720 SRV723 SRV722 SRV728 SRV724 SRV742 SRV740 # Description of Part This page intentionally left blank Warranty for Heat & GLO Lifestyle Collection Fireplaces WarrantyDo not Discard this Manual