5 Appliance Preparation

CAUTION

Sharp Edges

Wear protective gloves and safety glasses during installation.

A.Remove Logs and Shipping Cover

Open the doors by sliding the handles toward the outside edges of the doors (see Figure 5.1) Remove the cartons of logs from their shipping location in the appliance.

Open

 

Open

 

 

 

 

Figure 5.1 Door Operation

B. Securing and Leveling Appliance

WARNING

Fire Risk

Prevent contact with sagging, loose insulation.

Do NOT install against vapor barriers or exposed insulation.

The diagram shows how to properly position, level, and se- cure the appliance (see Figure 5.2). Nailing tabs are pro- vided to secure the appliance to the framing members.

Place the appliance into position on either a combustible or non-combustible continuous flat surface.

Note: Remove the top standoffs before sliding appliance into position if using an FPS prefab enclosure.

Level the appliance from side to side and front to back.

Shim the appliance with non-combustible material, such as sheet metal, as necessary.

Bend out nailing tabs on each side.

Keep nailing tabs flush with the framing.

Secure the appliance to the framing by using nails or screws through the nailing tabs.

Upper front can be

covered with

non-combustible

material or removed

and replaced with

non-combustible

material.

NAILING TABS

Figure 5.2 Proper Positioning, Leveling and Securing of an

Appliance

CAUTION

Do NOT notch into the framing around the appliance spacers.

Heat & Glo LifeStyle Collection • Dakota 42-B/Dakota 42H-B4036-909 Rev D • 08/06

9

Image 9
Contents What to do if you smell gas This appliance must be installed outsideListing Label Information/Location CongratulationsTable of Contents Listing and Code Approvals High Altitude InstallationsAppliance Certification Glass SpecificationsGetting Started Design and Installation Considerations¨ Moisture Resistance Tools and Supplies NeededSelect Appliance Location Framing and ClearancesFire Risk Fire Risk Odor RiskMantel Projections ClearancesVent Termination Minimum Clearances Termination LocationsAppliance Preparation Remove Logs and Shipping CoverSecuring and Leveling Appliance Fuel Conversion Gas Connection Gas InformationGas Pressure Fire Risk Explosion RiskFire Risk Explosion Risk Asphyxiation Risk Lift Out Doors Valve AccessConnecting to the Appliance Recommendation for Wire Intellifire Ignition System WiringElectrical Information Shock Risk Explosion RiskFireplace FinishingFacing Material Noncombustible Facing DiagramClean the Appliance Appliance SetupGrate Assembly Placement Positioning the LogsFront Left Log SRV722 Placing Lava Rock Glass AssemblyOperating Instructions Before Lighting ApplianceFire Risk Burn Risk Lighting the Appliance For Your Safety Read Before Lighting Lighting InstructionsFire Risk High Temperatures Frequently Asked QuestionsIssue Solutions After the Appliance is LitTroubleshooting Symptom Possible Causes Corrective ActionsIntellifire Ignition System Maintaining and Servicing the Appliance Tools Required Valve Service and ReplacementGround Wire Inspect Maintenance Tasks Maintenance and Service TasksReference Materials Appliance Dimension DiagramDAKOTA42-B Series ¨ B. Service Parts ListDescription of Part Replaced by SRV4036-260 Pre Serial #OD9288 Also available Battery Pack 593-594ASRV727 SRV720 SRV723 SRV722 SRV728 SRV724 SRV742 SRV740 # Description of Part This page intentionally left blank Warranty Warranty for Heat & GLO Lifestyle Collection FireplacesDo not Discard this Manual