TEMPERATURE CHART
Here is a chart for measuring properly cooked meat temperature: (USDA Standard)
Ground Meat & Meat Mixtures |
| |
Turkey, Chicken | 165°F | (74°C) |
Veal, Lamb | 160°F | (71°C) |
Beef, Pork | 160°F | (71°C) |
Fresh Beef |
|
|
Medium Rare | 145°F | (63°C) |
Medium | 160°F | (71°C) |
Well Done | 170°F | (77°C) |
Fresh Lamb |
|
|
Medium Rare | 145°F | (63°C) |
Medium | 160°F | (71°C) |
Well Done | 170°F | (77°C) |
Fresh Veal |
|
|
Medium Rare | 145°F | (63°C) |
Medium | 160°F | (71°C) |
Well Done | 170°F | (77°C) |
Poultry |
|
|
Chicken, whole | 180°F | (82°C) |
Turkey, whole | 180°F | (82°C) |
Breast, roast | 170°F | (77°C) |
Thighs, wings | 180°F | (82°C) |
Duck and Goose | 180°F | (82°C) |
Fresh Pork |
|
|
Medium | 160°F | (71°C) |
Well Done | 170°F | (77°C) |
Ham |
|
|
Fresh (raw) | 160°F | (71°C) |
140°F | (60°C) |
Fish
(Cook until opaque and flakes easily)
Note: These temperatures are measured with a meat probe thermometer. The heat indicator on the door of the smoker is not an accurate meat temperature reading.
TROUBLESHOOTING
PROBLEM | CAUSE | CORRECTION |
Electric | 1. Check that the | 1. Reseat plug in a |
element | ||
will not | seated into a | GFCI outlet wired for |
heat up | 120 volts and pro- | |
| GFCI outlet wired | tected at 15 or 20 |
| for 120 volts and | amps. |
| protected at 15 or |
|
| 20 amps. |
|
| 2. Check the break- | 2. Reset breakers or |
| ers or fuses for the | replace fuse. |
| outlet being used |
|
| are not open or |
|
| shorted. |
|
| 3. Check that the | 3. Reset GFCI outlet. |
| GFCI outlet has |
|
| not been tripped. |
|
| 4. Electric element | 4. Replace element. |
| may be damage |
|
| and needs |
|
| replacing. |
|
|
|
|
Smoker is | 1. Adjust temperature | 1. Turn up heat on |
not getting | control on electric | control dial. |
hot enough | element. |
|
| 2. Avoid the tempta- | 2. Opening the door |
| tion to check food | allows heat to |
| too often. | escape and slows |
|
| the cooking process; |
|
| open door only when |
|
| necessary. |
| 3. Extension cord is | 3. Do not use an exten- |
| wrong type. | sion cord unless ab- |
|
| solutely necessary. |
|
| Use the shortest |
|
| length possible. Use |
|
| a 12/3 or 14/3 |
|
| |
|
| tension cord with a |
|
| rating of at least 15 |
|
| amps. |
| 4. Electric element | 4. Replace element. |
| may be damaged |
|
| and needs |
|
| replacing. |
|
Smoker is | 1. Adjust temperature | 1. Turn down heat on |
getting | control on electric | control dial. |
too hot | element. |
|
| 2. Electric element | 2. Replace element. |
| may be damaged |
|
| and needs |
|
| replacing. |
|
|
|
|
15