TROUBLESHOOTING

SYMPTOM

POSSIBLE CAUSE

SUGGESTED REMEDY

 

Gas supply off

Check main / unit gas valves

Pilot will not light

Air in lines

Turn pilot valve on. Attempt to light

pilot every 15 sec.

 

 

 

Pilot valve not on

Turn pilot valve on / adjust

 

Gas supply off

Check main / unit gas valves

 

Air in lines

Turn gas valve on. Attempt to light

Burners won’t light

pilot every 15 sec.

 

 

Turn off gas - allow unit to vent for 5

 

 

 

Pilot burner not lit

minutes. Turn gas back on and light

 

 

pilot

 

Control not on

Turn control knob to ON, Set to

 

desired setting when lit

 

 

One burner assembly won’t

Water in burner

Remove burner and dry thoroughly

light

 

 

Damaged gas control valve,

Contact Authorized Wells Service

 

 

burner or other internal

 

Agency for repairs

 

component

 

 

Portions of a burner won’t

Burner wet or flame opening(s)

Clean and dry burner

light or have erratic flame

clogged

 

 

 

 

 

Temperature control not set

Adjust for desired temperature

 

Shutter or nozzle out of

Contact qualified technician for

Burner not hot enough

adjustment

adjustment

Damaged gas control valve,

Contact Authorized Wells Service

 

 

burner or other internal

 

Agency for repairs

 

component

 

 

NOTE: There are no user serviceable components in the burner assemblies or in the control valves. In all cases of damage or malfunction, contact your Authorized Wells Service Agency for repairs.

12

M163 2M-306981 Owners Manual for HDCB-Series Gas Char-Broilers

Page 14
Image 14
Wells HDCB1230G, HDCB3630G, HDCB2430G, HDCB4830G owner manual Troubleshooting, Symptom Possible Cause Suggested Remedy