Coleman 9998 Series manual Leak Testing Refillable Cylinders, How to Check for Leaks

Page 12

20# LP Cylinder Installation (continued)

4. Check that all grill burner knobs are in the off position (Fig. 42).

Fig. 42

5.Remove the protective caps from the cylinder valve and coupling nut. NOTE: The coupling nut connects to the large outside threads on the valve outlet.

6.Hold the hose in one hand and insert the nipple into the valve outlet. Be sure the nipple is centered in the valve outlet. Hand-tighten the coupling nut, taking care not to cross-thread the connection (Fig. 43).

Fig. 43

No Smoking

TYPE 1

7.Turn the coupling nut clockwise, tighten to a full stop. If you cannot complete the final connection, disconnect the coupling nut and repeat steps 6 and 7. If you are still unable to complete the connection, DO NOT use this hose and valve!

8.Check that the hose has no kinks or sharp bends and clears areas that will become hot during use. Never put strain on the hose where it joins a fitting.

9.BEFORE lighting grill, check all connections for leaks using the procedure as shown in the section titled “LEAK TESTING”.

Leak Testing - Refillable Cylinders

DANGER

TO PREVENT FIRE OR EXPLOSION HAZARD:

NO SMOKING. DO NOT use or permit sources of ignition in the area while doing a leak test.

Perform leak tests outdoors only.

NEVER perform a leak test with fire or flame.

How to Check for Leaks

1.Make a soapy solution of equal parts mild liquid dishwashing detergent and water.

2.Turn off all burner control knobs.

3.Turn on the fuel supply by turning the cylinder valve knob counterclockwise (right to left) one rotation.

4.Apply a soap solution to the connections indicated with the arrows in Fig. 44. If bubbles appear at these areas, a leak is indicated.

Fig. 44

No Smoking No Flame

REPRESENTATIVE ILLUSTRATION

12

Image 12
Contents Use, Care & Assembly Manual Contents General Safety InformationGeneral Installation Electrical AttachmentsCylinder Specifications Portable L.P. Gas Barbecue CylindersGas Cylinder Hose and Regulator Transporting the Refillable CylinderGrill Features 9998 Series Parts Identification 9998 Series Grill Assembly Assemble the WheelsAssemble the Wind Screen Assemble the Grease DiverterAssemble the Grill Lid Assemble the Propane Tank RetainerAssemble the Thermometer Assemble the Doors and the Tool Hook Assemble the Doors Handles20# LP Cylinder Installation Assemble the Side TablesLeak Testing Refillable Cylinders How to Check for LeaksWhen to test for leaks Fixing a Fuel LeakStart-Up Check List If you detect a leakLighting Instructions Lighting the BurnersMatch Lighting Shutting Off the Grill General Use and Correct Burner FlamesCondition The Grill Burner FlameCare, Maintenance and Cleaning Grilling Tips and HintsCase of Grease Fire Cooking MethodsCleaning the Venturi Suggested Cleaning MaterialsComponent Cleaning Steps For Cleaning VenturiReinstall the burners, heat tents and the cooking grates Troubleshooting Moving and StorageFor Your Additional Safety Special Note Concerning L.P. GAS CylindersColeman¨ Grill Warranty Registration Card Congratulations on Your NEW Coleman Grill Purchase Replacement Parts List 9998 Series Warranty Limited Three Year Warranty