18Outdoor Installation Instructions Beefeater Barbecues
1 | 2 |
WARNING: Contact your local municipality for any building codes regulating the installation of outdoor barbecue appliances. Outdoor installations must conform to local codes or, in the absence of local codes, with the following.
USA: National Fuel Gas Code, ANSI Z223.1/NFPA 54
CAN: B149.1 Natural Gas & Propane Installation Code.
AUST: Australian Standards Code AS: 5601
We recommend that this installation be done in a masonry structure and carried out by a professional tradesperson. Other
This appliance must not be installed under or on any combustible material. Minimum clearance from combustible construction materials to all sides of the appliance is 450mm (18”).
When using an LPG/Propane supply system in an enclosure, ventilation must be provided. Gas vapour is highly explosive and can cause serious bodily injury or damage to property if allowed to accumulate in a confined space and ignited.
500mm min
Barbecue Width
2 Burner 508mm
3 Burner 671mm
4 Burner 828mm 230mm min
5 Burner 985mm
Typical Installation Drawing
Propane (LPG) Installation
20mm min rear clearance
QCC LPG Cylinder (not included)
AGA approved Propane regulator (not included)
Natural Gas Installation
AGA approved |
Natural Gas |
regulator |
Shut off valve Stainless steel flex line or AGA approved (not included) hose (not included)