3Com FE100 manual 6RIWZDUH, $Sso\Lqjwkh&Oxvwhu+Rwil

Page 29

6HWWLQJ￿8S￿WKH￿6KDUHG￿6WRUDJH￿6XEV\VWHP￿)LEUH￿&KDQQHO￿ 'LVN￿'ULYHV

NOTE: When formatting disks from one node, you must power down the second node. Reboot both nodes after the configuration is modified.

You must set up the Fibre Channel disk drives in the shared storage subsystem for clustering. The first step is to configure the RAID level for the shared storage sub- system using the Dell OpenManage Data Supervisor or, if available, Data Administrator. Refer to the Dell OpenManage Data Supervisor Installation and Opera- tion Guide or the Dell OpenManage Data Administrator Installation and Operation Guide for instructions on setting up a RAID in the PowerVault storage system.

After the RAID is set up, partition and format the Fibre Channel disk drives in the shared storage subsystem, and assign drive letters to each LUN. For instructions on partitioning and formatting the shared storage subsystem hard-disk drives, refer to the Microsoft Windows NT Server, Enterprise Edition Administrator’s Guide and the Dell OpenManage Data Supervisor Installation and Operation Guide or the Dell Open- Manage Data Administrator Installation and Operation Guide. See “Naming and Formatting Shared Drives” in Chapter 3 of this guide to assign drive letters for the shared storage disk drives.

,QVWDOOLQJ￿DQG￿&RQILJXULQJ￿WKH￿0LFURVRIW￿&OXVWHU￿6HUYHU￿

6RIWZDUH

Like Windows NT Server, Enterprise Edition, you must install the Cluster Server soft- ware on both nodes if it has not already been done. Refer to the Microsoft Cluster Server Administrator’s Guide for instructions on installing and configuring the cluster- ing software. Also refer to Chapter 3, “Configuring the Cluster Software,” in this guide for specific information about installing and configuring Microsoft Cluster Server on your PowerEdge Cluster FE100.

NOTE: When you set up the Microsoft Cluster Server software, Dell recommends that you create a new domain account for the cluster administrator. Do not use the current administrator account or any other account whose password changes frequently.

$SSO\LQJ￿WKH￿&OXVWHU￿+RWIL[

After you install Microsoft Cluster Server, you must apply either the cluster hotfix (if you are running Windows NT Service Pack 3) or you must reapply the Windows NT Service Pack 4.

If you are using Windows NT Service Pack 3, you must install the post-Service Pack 3 hotfix, clusfixi.exe. Download the clusfixi.exe hotfix from the following FTP site:

ftp://ftp.microsoft.com/bussys/winnt/winnt-public/fixes/usa/nt40/hotfixes- postSP3/roll-up/cluster/

If you are using Windows NT Service Pack 4, simply reapply the service pack.

Getting Started 1-11

Image 29
Contents Zzzghoofrp 167$//$7,21$1 7528%/6+227,1Page $51,1*7KLVV\VWHPPD\KDYHPRUHWKDQRQHSRZHUVXSSO\FDEOH7R 6DIHW\,QVWUXFWLRQVKHQ8VLQJRXU&RPSXWHU6\VWHP 6DIHW\,QIRUPDWLRQIRU7HFKQLFLDQVKHQRUNLQJ,QVLGHRXU&RPSXWHU UJRQRPLF&RPSXWLQJ+DELWV3URWHFWLQJ$JDLQVWOHFWURVWDWLFLVFKDUJH Lqvwuxfwlrqvdwwkhiurqwriwklvjxlgh Page $ERXW7KLV*XLGH 3UHIDFHDUUDQW\DQG5HWXUQ3ROLF\,QIRUPDWLRQ 2WKHURFXPHQWDWLRQRX0D\1HHG1RWHV&DXWLRQVDQGDUQLQJV 1RWDWLRQDO&RQYHQWLRQVExample del drive path filename /p \SRJUDSKLFDO&RQYHQWLRQVNo boot device available Xvi Kdswhu RqwhqwvDEOLQJWKH&OXVWHU+DUGZDUH $SSHQGL$ Kdswhu 5XQQLQJ$SSOLFDWLRQV6RIWZDUH$SSHQGL% $SSHQGL HOO3RZHUGJH&OXVWHU7DEOHV $SSHQGL DUUDQW\5HWXUQ3ROLF\DQGHDUQGH Ljxuhv HWWLQJ6WDUWHG 0LQLPXP6\VWHP5HTXLUHPHQWV 3RZHUGJH&OXVWHU&RPSRQHQWVGetting Started DVLF,QVWDOODWLRQ3URFHGXUH $GGLQJ3HULSKHUDOV5HTXLUHGIRU&OXVWHULQJ LJXUHDPSOHRID3RZHUGJH1RGH Host bus adapters 2 required RQILJXULQJWKH4/RJLF+RVW%XV$GDSWHUV DEOLQJWKH&OXVWHU+DUGZDUH6HWWLQJ8SWKH,QWHUQDO6&6,+DUGLVNULYHV RQILJXULQJWKH&OXVWHU1,&V QVWDOOLQJDQG&RQILJXULQJLQGRZV176HUYHU QwhusulvhglwlrqQVWDOOLQJWKHHYLFHULYHUIRUWKH$7,9LGHR&RQWUROOHU QVWDOOLQJHOO2SHQ0DQDJH$7$SSO\LQJWKH&OXVWHU+RWIL 6RIWZDUHDWD$GPLQLVWUDWRU KHFNLQJWKH6\VWHPOXVWHU&DEOLQJ DEOLQJWKH&OXVWHU+DUGZDUHDEOLQJWKH3RZHUGJH&OXVWHU QVWDOOLQJ2SWLFDOLEHU,QWHUIDFH&DEOHV SDQGLQJWKH3RZHU9DXOW6WRUDJH6\VWHP DeolqjRQQHFWLQJ6WDQGE\3RZHU6XSSOLHVLQWKH3RZHU9DXOW 6\VWHP 3RZHU&DEOLQJLJXUH&DEOLQJWKH3RZHU9DXOW3RZHU6XSSOLHV 0RXVH.H\ERDUGDQG0RQLWRU&DEOLQJ Page +DUG/RRS,IRUWKH4/RJLF+RVW%XV$GDSWHUV RZ/HYHO6RIWZDUH&RQILJXUDWLRQ$,/HYHOIRUWKH,QWHUQDO+DUGLVNULYHV2SWLRQDO $,/HYHOIRUWKH6KDUHG6WRUDJH6XEV\VWHPQVWDOOLQJ+32SHQ9LHZ1HWZRUN1RGH0DQDJHU +LJK/HYHO6RIWZDUH&RQILJXUDWLRQType Managed Node Agent in the Name field 5HVRXUFH5XQQLQJHOO2SHQ0DQDJHDWD$GPLQLVWUDWRULQD&OXVWHU 6WDWLF,3$GGUHVVHV 5XQQLQJHOO2SHQ0DQDJH$7KRRVLQJDRPDLQ0RGHO 1DPLQJDQGRUPDWWLQJ6KDUHGULYHV ULYHUIRUWKH2SWLRQDO3RZHUGJHSDQGDEOH5$ Rqwuroohu 8VLQJWKHIWGLVNULYHUKDQJLQJWKH,3$GGUHVVRID1RGH 8SGDWLQJWKHLQGRZV17ULYHUIRU,QWHO1,&V$GMXVWLQJWKH3DJLQJLOH6LHDQG5HJLVWU\6LHV RJLF+RVW%XV$GDSWHUULYHU 9HULI\LQJWKH&OXVWHUXQFWLRQDOLW\Oxvwhurpdlq 9HULI\LQJWKHLQGRZV176HUYLFH3DFN9HUVLRQ 2SWLRQDO5$,&RQWUROOHUULYHU6KDUHG6WRUDJH6XEV\VWHPULYH/HWWHUV $YDLODELOLW\RI&OXVWHU5HVRXUFHV OXVWHU1HWZRUN&RPPXQLFDWLRQVOXVWHU6HUYLFH 6HWWLQJ8SWKH4XRUXP5HVRXUFH 5HPRYLQJD1RGHURPD&OXVWHUQVWDOOLQJDQG&RQILJXULQJ$GGLWLRQDO1,&V LQD&OXVWHU IP Address Subnet Mask 8SGDWLQJDQLVWLQJ6HUYLFH3DFN OXVWHUWR6HUYLFH3DFNHWHUPLQLQJWKH5$,/HYHOVRIWKH6KDUHG LVN9ROXPHV WKH&OXVWHU 5XQQLQJ$SSOLFDWLRQV6RIWZDUHRQ D&OXVWHU69HUVLRQ9LUWXDO5RRW6HUYLFH QVWDOOLQJ&OXVWHU$ZDUH$SSOLFDWLRQV6RIWZDUHLOH6KDUH6HUYLFH 3ULQW6SRROHU6HUYLFH Running Applications Software on a Cluster Select Remote print server \\spoolname and click Next 7DSH%DFNXSIRU&OXVWHUHG6\VWHPV 5XQQLQJFKNGVNIRQD4XRUXPLVNPage 7URXEOHVKRRWLQJ Microsoft Cluster Server Administrator’s Guide7DEOH7URXEOHVKRRWLQJFRQWLQXHG Microsoft Cluster Server suc Page 8SJUDGLQJWRD&OXVWHU Rqiljxudwlrq $GGLQJSDQVLRQ&DUGVIRUD&OXVWHU 8SJUDGH KHFNLQJRXULVWLQJ+DUGZDUHLJXUH$DPSOHRID3RZHUGJH1RGH Drac II optional OXVWHUDWD6KHHW Page Dell PowerEdge Cluster Installer Data Card and Checklist HOO3RZHU9DXOW&RQILJXUDWLRQDQGHOO2SHQ0DQDJH8WLOLWLHV RQILJXUDWLRQ0DWUL PowerEdge Cluster Model Configuration Matrix LWK3RZHUGJH6\VWHPV Page 5HJXODWRU\1RWLFHV ODVV$ 1RWLFHV862QO\ODVV% 1RWLFH&DQDGD2QO\Wdnhdghtxdwhphdvxuhv 1RWLFHXURSHDQ8QLRQVCCI-A ODVV%HYLFH 02&1RWLFH6RXWK.RUHD2QO\ODVV$HYLFH EMI B 8ZNBHBOJB1PMTLJFHP$FOUSVN#BEBËJ $FSUZGJLBDKJ120,QIRUPDWLRQ0HLFR2QO\ 1PPTUBFJOTUSVLDKFCFQJFDFËTUXBBciq Notice Taiwan Only Page RYHUDJHXULQJHDU2QH DUUDQW\5HWXUQ3ROLF\DQGHDU 6WDWHPHQWRI&RPSOLDQFHHQHUDO3URYLVLRQV RYHUDJHXULQJHDUV7ZRDQG7KUHH´7RWDO6DWLVIDFWLRQµ5HWXUQ3ROLF\86DQG &DQDGD2QO\ 3UHYLRXV3URGXFWV HDU6WDWHPHQWRI&RPSOLDQFHIRU HOO%UDQGHG+DUGZDUH3URGXFWV$GGLWLRQDO,QIRUPDWLRQ Page ATF QGHDPE PCI Scsi