Brinkmann Gas FirePit owner manual Rectangular GAS Firepit Specifications, Cylinder Specifications

Page 5

RECTANGULAR GAS FIREPIT SPECIFICATIONS:

 

Product name

Rectangular Gas Firepit

 

 

 

 

 

 

Model No.

832-7000-S

 

 

 

 

 

 

Rated Heat Output

40,000 BTU/HR

 

 

 

 

 

 

Fuel

Propane-LPG

 

 

 

 

 

 

Gas Supply

20 lb. LP-gas cylinder

 

 

 

 

 

 

Manifold Pressure

11 inches water column

 

 

 

 

 

 

Orifice Size (diameter)

1.96(0~+0.02)mm

 

 

 

 

 

 

Gas Supply Pressure

Maximum 250 PSI

 

 

 

 

 

 

 

 

 

 

 

WARNING

 

 

 

 

LP GAS CYLINDER (NOT SUPPLIED WITH THIS FIREPIT)

The LP cylinder is available for purchase at the same location the firepit was purchased.

The LP (Liquid Propane) gas cylinder specifically designed to be used with this firepit must have a 20 lb. (9.1 kg) capacity incorporating a Type 1 cylinder valve and an over-filling protection device (OPD).

DO NOT connect this firepit to an existing #510 POL cylinder valve with Left Hand threads. The Type 1 valve can be identified with the large external threads on the valve outlet.

DO NOT connect to a propane cylinder exceeding this capacity.

DO NOT connect to a cylinder that uses any other type of valve connection device.

CYLINDER SPECIFICATIONS:

When purchasing or exchanging a cylinder for your gas firepit, it must be constructed and marked in accordance with the specifications for LP gas cylinders of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339 Cylinders, Spheres and Tubes for Transportation of Dangerous Goods; and Commission, as applicable; and provided with a listed over-filling prevention device (OPD), and provided with a cylinder connection device compatible with the connection for outdoor gas fireplace.The cylinder must be provided with a shut off valve terminating in a LP-gas supply cylinder valve outlet specified, as applicable, for connection No. 791 in the Standard for cylinder connection devices, ANSI 221.81. CSA 6.25.

The cylinder must also be equipped with:

A shut-off valve terminating in a Type 1 gas cylinder valve outlet.

A Type 1 valve that prevents gas flow until a positive seal is obtained.

An arrangement for vapor withdrawal.

A collar to protect the cylinder shut-off valve.

A safety relief device having direct communication with the vapor space of the cylinder.

A listed over-filling prevention device (OPD).

4

Image 5
Contents For Outdoor USE only Solo Para USO AL Aire Libre Aviso Para EL InstaladorWhat to do if YOU Smell GAS? Important SafetyTable of Contents Important Safety Information Cylinder Specifications Rectangular GAS Firepit SpecificationsPage Regulator Resetting Procedure Installing the LP GAS Cylinder Onto the FirepitFilling the LP GAS Cylinder Hose and RegulatorConnecting Hose and Regulator Connecting Hose and Regulator to AN LP GAS CylinderChecking for Leaks Leak TestingWhen to Perform a Leak Test Location PRE-START Check ListMatch Lighting the Burner Lighting InstructionsLighting the Burner Turning OFF the GAS Firepit Storage & MaintenanceProblem Observed Possible Cause Corrective Measures Trouble ShootingParts BAG Contents For Firepit Warranty Replacement PARTS, Please Visit US AT Assembly InstructionsParts List Step Cylinder Clamp Screw Step Place firepit grate directly over burner assembly Charmglow Rectangular Gas Firepit Assembled ¿QUE Hacer SI Usted Huele GAS? Importantes Advertencias DE SeguridadÍndice Información Importante DE Seguridad Especificaciones DEL Cilindro Especificaciones Para Calentador Rectangular a GASPeligro Procedimiento DE Reposición DEL Regulador Llenando EL Cilindro DE GAS DE Propano LíquidoManguera Y Regulador Conexión DE LA Manguera Y Regulador Verificación DE Ausencia DE Fugas Pruebas DE Detección DE FugasCuándo Realizar UNA Prueba DE Detección DE Fugas Ubicacion Lista DE Verificación Preliminar AL EncendidoEncendido DE LAS Hornillas Principales CON UN Cerillo Instrucciones DE EncendidoEncendido DE LA Hornilla Apagando EL Calentador CuidadoProblema Causas Posibles Medidas Correctivas Identificación Y Corrección DE ProblemasContenido DE LA Bolsa DE Partes Lista DE Partes Instrucciones DE ArmadoPaso Tornillo de Abrazadera para el Cilindro Paso Arregle piedras de lava sobre la rejilla de calentador Charmglow Rectangular Calentador de Fuego a Gas Armada Warranty