Check for gas leaks

 

To perform leak checks: Slide back the collar of the

 

 

 

 

quick disconnect. Push the male fitting of the hose into

 

m DANGER

 

 

 

 

 

the quick disconnect, and maintain pressure (1). Slide

 

 

Do not use an open flame to check for gas

 

 

 

 

 

the collar closed (2). If it does not engage or lock,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

leaks. Be sure there are no sparks or open

 

 

repeat procedure. Gas will not flow unless the quick

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

flames in the area while you check for

 

 

disconnect is properly engaged.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

leaks. Sparks or open flames will result in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a fire or explosion, which can cause

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

serious bodily injury or death and damage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to property.

 

 

 

(2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

m WARNING: You should check for gas leaks every

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

time you disconnect and reconnect a gas fitting.

 

 

 

 

 

 

 

 

 

 

 

 

Note - All factory-made connections have been

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

thoroughly checked for gas leaks. The burners have

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

been flame-tested. As a safety precaution however, you

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

should recheck all fittings for leaks before using your

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weber Gas Barbecue. Shipping and handling may

 

Turn on gas supply.

 

 

 

loosen or damage a gas fitting.

 

 

 

Check for leaks by wetting the connections with the

 

 

m WARNING: Perform these leak checks even if

 

 

 

soap and water solution and watching for bubbles. If

 

your barbecue was dealer or store assembled.

 

 

 

bubbles form or if a bubble grows, there is a leak.

 

You will need: a soap and water solution, and a rag or

 

 

 

Note – Since some leak test solutions, including soap

 

 

brush to apply it.

 

 

 

and water, may be slightly corrosive, all connections

 

Note - Since some leak test solutions, including soap

 

 

 

 

 

should be rinsed with water after checking for leaks.

 

and water, may be slightly corrosive, all connections

 

 

 

 

 

m WARNING: Do not ignite burners when leak

 

should be rinsed with water after checking for leaks.

 

 

 

checking.

 

Make sure side burner is OFF.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C-6

Image 24
Contents Gas Grill Liquid Propane GAS Units only Warranty Customer Service Center South Hicks Road Palatine, ILContents General Instructions Genesis Silver-C NG Page Page Page Page Assemble wheel frame Assemble frameContinue frame assembly Complete frame assemblyAdd front panel Add back panelAdd cooking box assembly Insert castersInstall Gas Supply General Specifications for Piping Ommend That this Installation be Done by a ProfessionalInstall igniter Gas Line PipingTest Connections Install manifold bracket Check that all burner valves are offConnect flexible hose to manifold Install the slide out bottom tray Install Lid Install the right end trim piece with tool holders Right swing-up work surfaceDo not use the swing-up work surface as a cutting Board Install side burner You will need side burnerInstall the left end trim piece and swing-up work SurfaceShown, do not push the trim piece in all Way and do not add bolts yetInstall the work surface Do not use the work surface as a cutting boardCheck for gas leaks Time you disconnect and reconnect a gas fittingYour barbecue was dealer or store assembled CheckingInstall Flavorizer Bars and Cooking Grates Retighten the fitting with a wrench and recheck forSet the cooking grates onto the ledges in the cooking Box with the rounded sides upInstalling the warming rack Install the bottom shelf Install the thermometerLighting To ExtinguishManual Lighting Lighting the Side Burner Lighting only the side burnerCleaning CookingStorage Annual Maintenance Inspection and Cleaning of the Weber Spider Stopper GuardsGeneral Maintenance Weber Spider Stopper GuardsReplacing Main Burners Crossover Ignition System Operations Flame is low when burner is on Burners burn with a yellow orOrange flame, in conjunction with Smell of gasSide Burner does not light Flame is low in High positionFlame is very yellow Conjunction with the smell of gas