Trane PKGP-PRC003-EN manual Heating Capacities Net WSC036A1 At 1200 CFM

Page 29

Performance

Data(3Ton)

Table PD-26 — 3 Ton Single Phase

Heating Capacities (Net) WSC036A1 At 1200 CFM

 

 

 

 

 

 

Outdoor

InstantaneousHeatingCapacity(Btuh/1000)

 

IntegratedHeatingCapacity(Btuh/1000)

Total Power in Kilowatts at

Temp

 

at Indicated Indoor Dry Bulb Temp.

 

 

 

at Indicated Indoor Dry Bulb Temp.1

 

 

Indicated Indoor Dry Bulb Temp.

F.

60

70

75

80

 

60

70

75

80

60

70

75

80

-8

9.9

8.8

8.1

7.5

 

8.9

7.9

7.3

6.8

2.32

2.36

2.38

2.39

-3

12.0

10.8

10.2

9.5

10.8

9.7

9.2

8.6

2.42

2.47

2.49

2.51

2

14.2

12.9

12.3

11.6

12.8

11.6

11.1

10.4

2.51

2.57

2.60

2.62

7

16.5

15.2

14.5

13.8

14.9

13.7

13.1

12.4

2.60

2.67

2.71

2.73

12

18.8

17.5

16.8

16.1

16.9

15.8

15.1

14.5

2.69

2.77

2.81

2.84

17

21.1

19.9

19.2

18.5

19.0

17.9

17.3

16.7

2.77

2.87

2.91

2.95

22

23.5

22.2

21.5

20.9

21.2

20.0

19.4

18.8

2.85

2.96

3.01

3.06

27

26.1

24.6

23.9

23.1

23.5

22.1

21.5

20.8

2.94

3.05

3.11

3.16

32

28.7

27.2

26.4

25.6

25.8

24.5

23.8

23.0

3.02

3.15

3.21

3.27

37

31.3

29.7

28.9

28.1

28.2

26.7

26.0

25.3

3.11

3.25

3.32

3.38

42

33.9

32.2

31.4

30.6

30.5

29.0

28.3

27.5

3.20

3.35

3.42

3.50

47

36.6

34.8

33.9

33.1

36.6

34.8

33.9

33.1

3.29

3.45

3.53

3.61

52

39.2

37.4

36.5

35.6

39.2

37.4

36.5

35.6

3.39

3.57

3.65

3.74

57

41.9

38.7

37.8

36.8

41.9

38.7

37.8

36.8

3.49

3.66

3.75

3.85

62

43.2

41.3

40.4

39.4

43.2

41.3

40.4

39.4

3.57

3.78

3.89

3.99

67

45.9

43.9

42.9

41.9

45.9

43.9

42.9

41.9

3.69

3.92

4.02

4.13

72

48.6

46.5

45.5

44.4

48.6

46.5

45.5

44.4

3.81

4.05

4.17

4.28

For other airflow conditions, see heating capacity correction factor (Table PD-39).

Net heating capacity and power input includes indoor fan heat at ARI esp. To obtain net heating at other conditions, subtract fan heat at this condition and add fan heat at new condition. Note:

1. Integrated heating capacities and powers include the effects of defrost in the frost region. All heating capacities and power (kw) are at 70% OD relative humidity and demand defrost cycle.

Table PD-27 — 3 Ton Three Phase

Heating Capacities (Net)

 

WSC036A3, A4, AW

At 1200 CFM

 

 

 

 

 

Outdoor

 

InstantaneousHeatingCapacity(Btuh/1000)

 

 

IntegratedHeatingCapacity(Btuh/1000)

Total Power in Kilowatts at

Temp.

 

 

at Indicated Indoor Dry Bulb Temp.

 

 

 

 

at Indicated Indoor Dry Bulb Temp.1

 

 

Indicated Indoor Dry Bulb Temp.

 

F.

60

70

75

80

 

60

70

75

80

 

60

70

75

80

 

-8

9.6

8.6

8.1

7.5

 

8.6

7.7

7.3

6.8

 

2.14

2.21

2.23

2.25

 

-3

11.7

10.7

10.1

9.5

 

10.5

9.6

9.1

8.6

 

2.25

2.32

2.35

2.38

 

2

13.9

12.8

12.3

11.6

 

12.5

11.5

11.1

10.4

 

2.36

2.44

2.47

2.50

 

7

16.3

15.1

14.5

13.9

 

14.7

13.6

13.1

12.5

 

2.46

2.54

2.58

2.62

 

12

18.6

17.4

16.8

16.1

 

16.7

15.7

15.1

14.5

 

2.55

2.65

2.69

2.73

 

17

20.9

19.8

19.2

18.5

 

18.8

17.8

17.3

16.7

 

2.64

2.75

2.80

2.85

 

22

23.4

22.1

21.5

20.8

 

21.1

19.9

19.4

18.7

 

2.73

2.85

2.90

2.95

 

27

26.0

24.6

23.9

23.2

 

23.4

22.1

21.5

20.9

 

2.82

2.95

3.00

3.06

 

32

28.6

27.2

26.4

25.7

 

25.7

24.5

23.8

23.1

 

2.91

3.04

3.11

3.17

 

37

31.2

29.7

28.9

28.2

 

28.1

26.7

26.0

25.4

 

3.00

3.14

3.21

3.28

 

42

33.9

32.2

31.4

30.6

 

30.5

29.0

28.3

27.5

 

3.09

3.24

3.32

3.39

 

47

36.5

34.8

34.0

33.1

 

36.5

34.8

34.0

33.1

 

3.18

3.34

3.42

3.50

 

52

39.2

37.4

36.5

35.6

 

39.2

37.4

36.5

35.6

 

3.28

3.45

3.53

3.62

 

57

41.8

38.7

37.8

36.8

 

41.8

38.7

37.8

36.8

 

3.37

3.53

3.63

3.72

 

62

43.2

41.3

40.3

39.3

 

43.2

41.3

40.3

39.3

 

3.44

3.65

3.75

3.85

 

67

45.8

43.9

42.9

41.8

 

45.8

43.9

42.9

41.8

 

3.55

3.76

3.87

3.98

 

72

48.5

46.4

45.4

44.3

 

48.5

46.4

45.4

44.3

 

3.65

3.88

4.00

4.11

 

For other airflow conditions, see heating capacity correction factor (Table PD-39).

Net heating capacity and power input includes indoor fan heat at ARI esp. To obtain net heating at other conditions, subtract fan heat at this condition and add fan heat at new condition. Note:

1. Integrated heating capacities and powers include the effects of defrost in the frost region. All heating capacities and power (kw) are at 70% OD relative humidity and demand defrost cycle.

PKGP-PRC003-EN

29

Image 29
Contents Packaged Heat Pumps American Standard Inc. All Rights Reserved IntroductionContents Factory or Field Installed Options Features BenefitsFactory Installed Options Field Installed Options Quality and Reliability Features and BenefitsEasy to Install, Service and Maintain ColoredAnd NumberedWiring Clogged Filter/Fan Failure SwitchBlack Epoxy Pre-Coated Coils Cabinet IntegrityPower Exhaust Option Phase MonitorQuick-Access Panels Quick-Adjust Idler ArmVentilation Override Accessory Rigorous TestingUnit Cabinet VariTracEasy to Install Added Efficiency Condensate Trap Barometric ReliefClearance Requirements Unit PitchHeating Capacity Cooling CapacityAir Delivery Selection Step036 11 12,13 Model Number DescriptionTable GD-1 General Data GeneralData Table GD-2 General Data General DataOutdoorSoundRatingdB3 Outdoor Coil -Type Outdoor Fan TypeTable GD-3 General Data ½, 10TonEER2 Outdoor Fan- TypeMBH SHC MBH SHC MBH SHC Performance DataMBH SHC Performance Ton Three Phase WSC060A1,A3, A4, AWMBH SHC MBH SHC MBH SHC MBH SHC MBH ½ Ton Three PhaseTon Three Phase Horizontal WSC036AWSC048A WSC060ATable PD-9 Data3TonTable PD-8 Table PD-10 Data4TonTable PD-11 HP Standard Motor & Field SuppliedTable PD-12 Data5TonTable PD-13 HP Standard Motor & Drive Low Static DriveTable PD-15 Data6TonTable PD-14 Table PD-16 Data7½TonTable PD-17 HP Oversized Motor& Field Supplied Sheave2Table PD-18 Data10 TonTable PD-19 HP Standard Motor & Drive HP Oversized Motor & DriveTable PD-22 Oversized Motor & Drive Sheave/Fan Speed Rpm Table PD-20- Standard Motor & Sheave/Fan Speed RpmWSC072A WSC090AWSC072A WSC090A WSC120A Table PD-25 Outdoor Sound Power Level dB ref -12WattsAt 1200 CFM Heating Capacities Net WSC036A1 At 1200 CFMAt 1600 CFM Heating Capacities Net WSC048A1 At 1600 CFMAt 2000 CFM Heating Capacities Net WSC60A1 At 2000 CFMWSC72A At 3000 CFM Downflow Configuration WSC120A Nominal Distribution Table PD-38 Auxiliary Electric Heat Capacity14.2 18.00 28.5 19.0 27.00 42.7 21.3 36.00 56.9 37.9 54.00 6Ton ½ Ton 10Ton 2000 3000 CFMWS120A3,A4,AW ReliaTel Controlled Units ControlsElectrical Data Table ED-1 Unit Wiring208/230 Volts Three Phase 208/230 Volts Single PhaseVolts Three Phase BAYHTR306A FLA LRA HP2 RPM RLA LRA Table ED-8 Electrical Characteristics Power ExhaustAMPS1 Amps Jobsite Connections Zone Sensors -Typical Number Of WiresData Tons DimensionalData Dimensional7½ Tons WSC072A and WSC090A Tons -WSC120A Dimensional DataTons Unit Clearance and Roof Opening SupplyTons Downflow Duct Connections Field Fabricated Tons Roof CurbSee Page 46 forThrough the Base Utilities Information Data AccessoriesTons Economizer, Manual, or Motorized Fresh Air DamperSee Page 48 forThrough the Base Utilities Information Table W-2 Factory-installed Options Net Weights Lbs1,2 WeightsMechanical Specifications Factory or Field Installed Options Factory Installed OptionsField Installed Options PL-UN-PKGP-WSC 3-10TONS-PRC003-EN-02-04 PL-UN-PKGP-WSC 3-10TONS-PRC003-EN-09-04

PKGP-PRC003-EN specifications

The Trane PKGP-PRC003-EN is a high-performance packaged rooftop unit designed to provide efficient heating, cooling, and ventilation solutions for a wide variety of commercial applications. Its innovative design encompasses advanced technologies aimed at improving energy efficiency and overall operational efficiency.

One of the standout features of the PKGP-PRC003-EN is its highly efficient variable speed compressor. This technology allows the unit to modulate its capacity based on the specific needs of the environment, ensuring optimal comfort levels while reducing energy consumption. Coupled with a robust fan system, the unit can maintain precise temperature control in fluctuating weather conditions, providing reliable comfort year-round.

The unit's advanced controls use a user-friendly interface that simplifies operation and monitoring. These controls can be integrated with building management systems (BMS), allowing for seamless connectivity and enhanced control over the HVAC system. With the capability for remote monitoring, facility managers can track performance metrics and receive alerts for maintenance, ensuring that the unit operates efficiently and minimizes downtime.

In terms of design, the PKGP-PRC003-EN is equipped with durable construction materials that withstand outdoor environments, ensuring a long lifespan with minimal maintenance. The unit’s compact footprint allows it to fit in tight spaces on rooftops, making it an ideal choice for urban environments where space is limited.

Furthermore, the Trane PKGP-PRC003-EN incorporates advanced filtration systems to improve indoor air quality. These filters effectively capture dust, pollen, and other allergens, contributing to a healthier indoor environment. The unit is also designed with sound attenuation features, minimizing operational noise, which is particularly beneficial for installations in noise-sensitive areas.

Overall, the Trane PKGP-PRC003-EN sets a high standard in the realm of rooftop HVAC solutions. Its combination of energy efficiency, smart control capabilities, and robust construction makes it a reliable choice for businesses looking to enhance their indoor climate while being mindful of operational costs. The integration of advanced technologies ensures that it not only meets but exceeds the expectations of modern HVAC performance, all while maintaining user-friendly operation and maintenance.