Trane PKGP-PRC003-EN manual High Pressure Cutout, LonTalk Communications Interface, Phase Monitor

Page 7

Features and Benefits

High Pressure Cutout

This factory-installed option is offered for units that do not have High Pressure Cutout as standard. All 3-phase units with scroll compressors include High Pressure cutout as standard.

High Static Drive Accessory Available on many models, this high static drive accessory extends the capability of the standard motor. Avoid expensive motors and operating costs by installing this optimized sheave accessory.

Hinged Access Doors

These doors permit easy access to the filter, fan/heat, and compressor/control sections. They

reduce the potential roof damage from screws or sharp access door corners.

LonTalk®

Communications

Interface

The LonTalk communications interface allows the unit to

communicate as aTracer™LCI-V device or directly with generic LonTalk Network Building Automation System Controls.

Phase Monitor

Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator.

Power Exhaust Option

This option is available to maintain proper building pressurization. Great for relieving most building overpressurization problems.

Quick-Access Panels

Remove two screws for access to the standardized internal components and wiring.

Quick-Adjust Idler Arm

With the Quick-Adjust Idler Arm, the belt and sheaves can be quickly adjusted without moving the mounted fan motor. The result is a major savings in time and money.

Reference or Comparative Enthalpy Measures and communicates humidity while maximizing comfort control.

Sloped Drain Pans

Every Precedent unit has a non- corrosive, removable, double-sloped drain pan that’s

easy to clean and reversible to allo w installation of drain trap on either side of the unit.

Standardized Components Components are placed in the same location on all Precedent units. Familiarize yourself with one Precedent and you are familiar with every Precedent.

Due to standardized components throughout the Precedent line, contractors/owners can stock fewer parts.

Supply and/or Return Air Smoke Detector

With this option installed, if smoke is detected, all unit operation will be shut down. Reset will be manual at the unit. Return Air Smoke Detectors require minimum allowable airflow when used with certain models.

Tool-less Hail Guards

Tool-less, hail protection quality coil guards shall be either factory or field- installed for condenser coil protection. This option protects the condenser coil from vandalism and/or hail damage.

Trane Communication Interface (TCI) Available factory or field installed.This module when applied with the ReliaTel™ easily interfaces withTrane’s Integrated ComfortTM System.

PKGP-PRC003-EN

7

Image 7
Contents Packaged Heat Pumps American Standard Inc. All Rights Reserved IntroductionContents Factory Installed Options Field Installed Options Features BenefitsFactory or Field Installed Options Easy to Install, Service and Maintain Features and BenefitsQuality and Reliability Cabinet Integrity Clogged Filter/Fan Failure SwitchColoredAnd NumberedWiring Black Epoxy Pre-Coated CoilsQuick-Adjust Idler Arm Phase MonitorPower Exhaust Option Quick-Access PanelsVariTrac Rigorous TestingVentilation Override Accessory Unit CabinetEasy to Install Added Efficiency Unit Pitch Barometric ReliefCondensate Trap Clearance RequirementsStep Cooling CapacityHeating Capacity Air Delivery Selection036 11 12,13 Model Number DescriptionData GeneralTable GD-1 General Data Outdoor Fan Type General DataTable GD-2 General Data OutdoorSoundRatingdB3 Outdoor Coil -TypeOutdoor Fan- Type ½, 10TonTable GD-3 General Data EER2MBH SHC Performance DataMBH SHC MBH SHC MBH SHC Performance Ton Three Phase WSC060A1,A3, A4, AWTon Three Phase ½ Ton Three PhaseMBH SHC MBH SHC MBH SHC MBH SHC MBH WSC060A WSC036AHorizontal WSC048ATable PD-8 Data3TonTable PD-9 HP Standard Motor & Field Supplied Data4TonTable PD-10 Table PD-11HP Standard Motor & Drive Low Static Drive Data5TonTable PD-12 Table PD-13Table PD-14 Data6TonTable PD-15 HP Oversized Motor& Field Supplied Sheave2 Data7½TonTable PD-16 Table PD-17HP Standard Motor & Drive HP Oversized Motor & Drive Data10 TonTable PD-18 Table PD-19WSC090A Table PD-20- Standard Motor & Sheave/Fan Speed RpmTable PD-22 Oversized Motor & Drive Sheave/Fan Speed Rpm WSC072AWSC072A WSC090A WSC120A Table PD-25 Outdoor Sound Power Level dB ref -12WattsAt 1200 CFM Heating Capacities Net WSC036A1 At 1200 CFMAt 1600 CFM Heating Capacities Net WSC048A1 At 1600 CFMAt 2000 CFM Heating Capacities Net WSC60A1 At 2000 CFMWSC72A At 3000 CFM Downflow Configuration WSC120A Nominal Distribution Table PD-38 Auxiliary Electric Heat CapacityWS120A3,A4,AW 6Ton ½ Ton 10Ton 2000 3000 CFM14.2 18.00 28.5 19.0 27.00 42.7 21.3 36.00 56.9 37.9 54.00 ReliaTel Controlled Units ControlsElectrical Data Table ED-1 Unit Wiring208/230 Volts Three Phase 208/230 Volts Single PhaseVolts Three Phase BAYHTR306A FLA LRA AMPS1 Amps Table ED-8 Electrical Characteristics Power ExhaustHP2 RPM RLA LRA Jobsite Connections Zone Sensors -Typical Number Of WiresData Tons DimensionalData Dimensional7½ Tons WSC072A and WSC090A Tons -WSC120A Dimensional DataTons Unit Clearance and Roof Opening SupplyTons Downflow Duct Connections Field Fabricated Tons Roof CurbFresh Air Damper Data AccessoriesSee Page 46 forThrough the Base Utilities Information Tons Economizer, Manual, or MotorizedSee Page 48 forThrough the Base Utilities Information Table W-2 Factory-installed Options Net Weights Lbs1,2 WeightsMechanical Specifications Factory or Field Installed Options Factory Installed OptionsField Installed Options PL-UN-PKGP-WSC 3-10TONS-PRC003-EN-02-04 PL-UN-PKGP-WSC 3-10TONS-PRC003-EN-09-04

PKGP-PRC003-EN specifications

The Trane PKGP-PRC003-EN is a high-performance packaged rooftop unit designed to provide efficient heating, cooling, and ventilation solutions for a wide variety of commercial applications. Its innovative design encompasses advanced technologies aimed at improving energy efficiency and overall operational efficiency.

One of the standout features of the PKGP-PRC003-EN is its highly efficient variable speed compressor. This technology allows the unit to modulate its capacity based on the specific needs of the environment, ensuring optimal comfort levels while reducing energy consumption. Coupled with a robust fan system, the unit can maintain precise temperature control in fluctuating weather conditions, providing reliable comfort year-round.

The unit's advanced controls use a user-friendly interface that simplifies operation and monitoring. These controls can be integrated with building management systems (BMS), allowing for seamless connectivity and enhanced control over the HVAC system. With the capability for remote monitoring, facility managers can track performance metrics and receive alerts for maintenance, ensuring that the unit operates efficiently and minimizes downtime.

In terms of design, the PKGP-PRC003-EN is equipped with durable construction materials that withstand outdoor environments, ensuring a long lifespan with minimal maintenance. The unit’s compact footprint allows it to fit in tight spaces on rooftops, making it an ideal choice for urban environments where space is limited.

Furthermore, the Trane PKGP-PRC003-EN incorporates advanced filtration systems to improve indoor air quality. These filters effectively capture dust, pollen, and other allergens, contributing to a healthier indoor environment. The unit is also designed with sound attenuation features, minimizing operational noise, which is particularly beneficial for installations in noise-sensitive areas.

Overall, the Trane PKGP-PRC003-EN sets a high standard in the realm of rooftop HVAC solutions. Its combination of energy efficiency, smart control capabilities, and robust construction makes it a reliable choice for businesses looking to enhance their indoor climate while being mindful of operational costs. The integration of advanced technologies ensures that it not only meets but exceeds the expectations of modern HVAC performance, all while maintaining user-friendly operation and maintenance.