22 | GAS SUPPLY |
|
|
c). If the remote LP cylinder enclosure has four sides, a top and a bottom, and is intended for installation in a
1). At least one ventilation opening (a hole or group of holes, for the purpose of ventilation) needs to be on one side of the enclosure that communicates with the outside of the “island” structure. If a gas leak should occur or the LP cylinder should vent in the LP cylinder enclosure, the gas should not be allowed to vent or migrate into the empty or “hollow” area of the “island”. Ventilation openings should only communicate with the outside of the “island” structure, so that the gas can dissipate outside of the “island” structure. The ventilation opening should be located within 5 inches (127mm) of the top of the enclosure, and should have a total free area of 20 square inches. (This relates to 1 square inch of ventilation area, per pound of stored fuel).
2). At least one ventilation opening (a hole or group of holes, for the purpose of ventilation) needs to be on one side of the enclosure that communicates with the outside of the “island” structure, at the bottom. If a gas leak should occur or the LP cylinder should vent in the LP cylinder enclosure, the gas should not be allowed to vent or migrate into the empty or “hollow” area of the “island”. Ventilation openings should only communicate with the outside of the “island” structure, so that the gas can dissipate outside of the “island” structure. The ventilation opening should be located within 5 inches (127mm) of the bottom of the enclosure, and should have a total free area of 10 square inches. (This relates to 1/4 square inch of ventilation area, per pound of stored fuel).
3). The minimum size of the ventilation hole (s) should not be less than 1/4 inch (6.35mm).
d). The remote LP cylinder enclosure should be constructed with
e). There should be a minimum of 2 inches (50.8mm) between the ground and the fl oor of the remote LP cylinder enclosure.
f). The LP cylinder valve should be readily accessible for hand operation. A door on the remote LP cylinder enclosure to gain access to the LP cylinder valve is acceptable, provided it is
DANGER
Use of any other hose and regulator assembly could be dangerous, and may not provide adequate gas supply to the Summit®
DANGER
Failure to use the Summit®
If you do not follow the DANGER statements exactly, the Warranty on the Summit® Built- In gas grill will be voided.
BUILT-IN TANK ENCLOSURE INSTRUCTIONS
OPERATING
WARNING: Only use the Weber® Tank Enclosure Kit outdoors in a
WARNING: Your Weber® Tank Enclosure Kit shall not be used under an unprotected combustible roof or overhang. WARNING: Your Weber® Tank Enclosure Kit is not intended to be installed in or on recreational vehicles and/or boats. WARNING: Keep any electrical supply cord and the fuel supply hose away from any heated surface.
WARNING: Never store an extra (spare) LP cylinder under or near the Weber® gas barbecue.
WARNING: Keep the ventilation openings of the cylinder enclosure free and clear of debris.
WARNING: Turn off the gas at the LP gas supply cylinder when the outdoor cooking gas appliance is not in use. WARNING: Never store an outdoor cooking gas appliance indoors unless the LP cylinder is disconnected and removed from the outdoor cooking gas appliance.
WARNING: LP Cylinders must be stored outdoors out of the reach of children and must not be stored in a building, garage, or any other enclosed area.
WARNING: The LP pressure regulator and hose assembly supplied with the Weber® Tank Enclosure Kit must be used. Replacement LP pressure regulators and hoses must be obtained from