GAS SUPPLY | 27 |
|
|
VENTILATION
WARNING: Air holes must be provided in the structure at the top and bottom to provide ventilation in the event of a gas leak.
Air holes can be located in a low visibility area and should be protected by screening material to prevent rodents and insects from entering the structure. Air holes will also help dry moisture.
Summit®
Note: These drawings are only a reference.
•Cross ventilation must be incorporated in the supporting structure. We recommend a minimum of 100 square inches (254 square cm )of venting per side.
•Vents should be on two sides of the structure.
• The above drawings are for reference only.
•Location of the vents should be from the center, outward.
• Locate the vents at both the bottom of the structure and at the top of the structure.
• The bottom vents should be as close to ground level as possible. Make sure the vent area is not blocked by interior supports of the structure.
• We recommend vents with screens.
•Access doors to the structure are not considered vents.
•Clean the vents periodically.
DANGER: Failure to follow recommended minimum venting instructions can cause gas to collect in the structure in the event of a gas leak. This may result in a fire or an explosion which can cause serious bodily injury or death, and damage to property.