Weber 1200 owner manual Install manifold bracket

Page 13

Your Weber Gas Barbecue burner assembly has been factory assembled, pressure and flame tested. As a safety precaution we recommend you check the burner alignment:

a)Do the valves fit into the ends of the burners? Figure 9 (a).

b)Are the ends of the burners under the washers at the left rear and left front of the cooking box? The screws are only guides. Do not tighten. Figure 9 (b).

c)Are the wing nuts under the burner assembly hand tight? Do not tighten with pliers. Figure 9 (c).

If you answered YES to a, b and c, the burners are correctly aligned. If you answered NO, the burners are misaligned. Contact Weber-Stephen Customer Service. Do not use barbecue.

Guide screw

Step 9

Install manifold bracket

You will need: manifold bracket

Hook the bracket onto the manifold at the center burner valve. Place your hand underneath the bracket. Lift the manifold, bracket and cooking box slightly and hook the tab of the bracket onto the frame brace. Figure 10.

Frame brace

Manifold bracket

Figure 10

(b)

(a)

View from behind cooking box

(c)

Figure 9

Wing nuts

13

Image 13
Contents Skyline LP GAS Units only MDANGER MWARNINGSWarranty Patents and Trademarks Contents Gas supply testing For Installation in CanadaGeneral Instructions StorageCheck package contents AssemblyStep Two wheels Check contents of hardware packs Assemble frame Assemble wheelsComplete frame assembly Continue frame assemblyInsert casters Add cooking box Add front panelInstall manifold bracket Install gas supply Install igniterGeneral Specifications for Piping Gas line piping Typical natural gas supply installation. FigureTest connections Check that all burner valves are offCheck for gas leaks MWARNING Do not ignite burners when leak checkingInstall the bottom tray Install Flavorizer Bars and Cooking GratesInstall the condiment basket Install LidAdd control panel and burner control knobs Install swing tableHinge rod Complete accessory installation To Extinguish LightingManual Lighting Cooking Periodic CleaningStorage and/or Nonuse Drippings and greaseInspection and Cleaning of the Weber Spider Stopper Guards Annual MaintenanceMWARNING Do not ignite burners while leak checking MCAUTION Do not enlarge the burner ports when cleaning General MaintenanceWeber Spider Stopper Guards Main Burner Flame PatternTo reinstall the burners, reverse steps c through g Crossover Ignition System Operations Burner does not light, or flame is low in High position Troubleshooting15-16 11,15 20-21 Parts List Final Word Thanks