Weber 1200 owner manual Install igniter, Install gas supply, General Specifications for Piping

Page 14

Step 10

Install igniter

Note - The igniter wires are already attached to the Gas Catcher Ignition Chamber and the igniter. This was done to factory test the ignition system.

The igniter lock nut is on the igniter.

Insert the top of the igniter up through the large part of the keyhole in the frame brace. Figure 11 (b). Loosen the igniter lock nut and slide the igniter into the small part of the keyhole. Figure 11 (c). Tighten the igniter lock nut. Figure 11.

Note - If the igniter works loose, carefully tighten the igniter lock nut with an adjustable wrench or pliers.

(a)

Frame brace

(b)

Figure 11

Keyhole in

 

frame brace

Igniter lock nut

 

 

(c)

Frame brace

Small part of keyhole in frame brace

Step 11

Install gas supply

General Specifications for Piping

Note - Contact your local municipality for building codes regulating outdoor gas barbecue installations. In absence of Local Codes, you must conform to the latest edition of ANSI Z223.1. WE RECOMMEND THAT THIS INSTALLATION BE DONE BY A PROFESSIONAL.

Some of the following are general requirements taken from ANSI Z223.1, for gas supply installations. Refer to ANSI Z223.1 latest edition for complete specifications.

This barbecue is designed to operate at 7 inches of water column pressure (.2526 psi).

A manual shut-off valve must be installed outdoors, immediately ahead of the quick disconnect.

An additional manual shut-off valve indoors should be installed in the branch fuel line in an accessible location near the supply line.

The quick disconnect connects to a 3/8 inch NPT thread from the gas source. The quick disconnect fitting is a hand-operated device that automatically shuts OFF the flow of gas from the source when the barbecue is disconnected.

The quick disconnect fitting can be installed horizontally, or pointing downward. Installing the fitting with the open end pointing upward can result in collecting water and debris.

The dust covers (supplied plastic plugs) help keep the open ends of the quick disconnect fitting clean while disconnected.

Pipe compound should be used which is resistant to the action of natural gas when connections are made.

The outdoor connector must be firmly attached to rigid, permanent construction.

mWARNING: Do not route the 12 foot hose under a deck. The hose must be visible.

14

Image 14
Contents Skyline MDANGER MWARNINGS LP GAS Units onlyWarranty Patents and Trademarks Contents General Instructions For Installation in CanadaGas supply testing StorageStep AssemblyCheck package contents Two wheels Check contents of hardware packs Assemble wheels Assemble frameInsert casters Continue frame assemblyComplete frame assembly Add front panel Add cooking boxInstall manifold bracket General Specifications for Piping Install igniterInstall gas supply Test connections Typical natural gas supply installation. FigureGas line piping Check that all burner valves are offMWARNING Do not ignite burners when leak checking Check for gas leaksInstall Flavorizer Bars and Cooking Grates Install the bottom trayInstall Lid Install the condiment basketInstall swing table Add control panel and burner control knobsHinge rod Complete accessory installation Lighting To ExtinguishManual Lighting Storage and/or Nonuse Periodic CleaningCooking Drippings and greaseMWARNING Do not ignite burners while leak checking Annual MaintenanceInspection and Cleaning of the Weber Spider Stopper Guards Weber Spider Stopper Guards General MaintenanceMCAUTION Do not enlarge the burner ports when cleaning Main Burner Flame PatternTo reinstall the burners, reverse steps c through g Crossover Ignition System Operations Troubleshooting Burner does not light, or flame is low in High position15-16 11,15 20-21 Parts List Final Word Thanks
Related manuals
Manual 36 pages 15.17 Kb