Weber 1200 owner manual Crossover Ignition System Operations

Page 28

mCAUTION: If the Spider Stopper Guards do not fit tightly, contact Weber-Stephen Customer Service.

mWARNING: After reinstalling the gas lines, they should be leak checked with a soap and water solution before using the barbecue. (See Step“Check for gas leaks”.)

Crossover Ignition System Operations

If the Crossover Ignition System fails to ignite the Front burner, light the Front burner with a match. If the Front burner lights with a match, then check the Crossover Ignition System.

Check that both the white and black ignition wires are attached properly. Figure 15.

White wire

Black wire

Figure 15

Check that the Crossover Ignition button pushes the igniter (button) down, and returns to the up position.

Check to see if the igniter is loose in the frame. Tighten if necessary; see Step “Install igniter” for correct procedure.

If the Crossover Ignition System still fails to light, See Section "Manual Lighting", and contact Weber-Stephen Customer Service.

28

Image 28
Contents Skyline MDANGER MWARNINGS LP GAS Units onlyWarranty Patents and Trademarks Contents For Installation in Canada Gas supply testingGeneral Instructions StorageCheck package contents AssemblyStep Two wheels Check contents of hardware packs Assemble wheels Assemble frameComplete frame assembly Continue frame assemblyInsert casters Add front panel Add cooking boxInstall manifold bracket Install gas supply Install igniterGeneral Specifications for Piping Typical natural gas supply installation. Figure Gas line pipingTest connections Check that all burner valves are offMWARNING Do not ignite burners when leak checking Check for gas leaksInstall Flavorizer Bars and Cooking Grates Install the bottom trayInstall Lid Install the condiment basketInstall swing table Add control panel and burner control knobsHinge rod Complete accessory installation Lighting To ExtinguishManual Lighting Periodic Cleaning CookingStorage and/or Nonuse Drippings and greaseInspection and Cleaning of the Weber Spider Stopper Guards Annual MaintenanceMWARNING Do not ignite burners while leak checking General Maintenance MCAUTION Do not enlarge the burner ports when cleaningWeber Spider Stopper Guards Main Burner Flame PatternTo reinstall the burners, reverse steps c through g Crossover Ignition System Operations Troubleshooting Burner does not light, or flame is low in High position15-16 11,15 20-21 Parts List Final Word Thanks
Related manuals
Manual 36 pages 15.17 Kb