Weber 2000 owner manual Check for gas leaks, MWARNING Do not ignite burners while leak checking

Page 16

Step 13

Check for gas leaks

mDANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. This will result in a fire or explosion which can cause serious bodily injury or death and damage to property.

mWARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting.

Note - All factory made connections have been thoroughly checked for gas leaks. The burners have been flame tested. As a safety precaution you should recheck all fittings for leaks before using your Weber Genesis Gas Barbecue. Shipping and handling may have loosened or damaged a gas fitting.

mWARNING: Perform these leak checks even if your barbecue was dealer or store assembled.

You will need: a soap and water solution and a rag or brush to apply it.

Note - Since some leaks test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks.

To perform leak checks: Slide back the collar of the quick disconnect. Push male fitting of the hose into the quick disconnect, and maintain pressure. Figure 14 (a). Slide the collar closed. Figure 14 (b). If it does not engage or lock, repeat procedure. Gas will not flow unless the quick disconnect is properly engaged.

Locking shut off

To barbecue

(a)

Outside house wall

Male fitting

Collar

(b)

Quick disconnect engaged

Figure 14

Turn on gas supply.

mWARNING: Do not ignite burners while leak checking.

Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows there is a leak.

Check:

a) Hose to manifold connection. Figure 15 (a).

mWARNING: If there is a leak at connection (a), retighten the fitting with a wrench and recheck for leaks with soap and water solution.

If a leak persists after retightening the fitting, turn OFF the gas. DO NOT OPERATE THE BARBECUE. Contact

Weber-Stephen Customer Service.

b)Valves to manifold connections. Figure 15 (b).

c)Hose to quick disconnect connection. Figure 15 (c).

mWARNING: If there is a leak at connections (b) or (c), turn OFF the gas. DO NOT OPERATE THE BARBECUE.

Contact Weber-Stephen Customer Service.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.

(a)

(b)

(c)

Figure 15

16

Image 16
Contents Genesis 2000 Series MDANGER MWARNINGS LP GAS Units onlyWarranty Patents and Trademarks Contents For Installation in Canada Gas supply testingGeneral Instructions StorageCheck package contents AssemblyStep Left hand slide bar assembly Check contents of hardware packs Assemble wheels Assemble frameComplete frame assembly Continue frame assemblyInsert casters Add cooking box Install manifold bracket Install igniterInstall gas supply General Specifications for PipingGas line piping Test connectionsCheck that all burner valves are off Connect flexible hose to manifoldCheck for gas leaks MWARNING Do not ignite burners while leak checkingInstall Flavorizer Bars and Cooking Grates Install the bottom trayInstall the lid Install tool holders, control panel and burner control knobsInstall swing table Complete accessory installation Lighting To ExtinguishManual Lighting Cooking Periodic CleaningStorage and/or Nonuse Annual Maintenance Inspection and Cleaning of the Weber Spider Stopper GuardsGeneral Maintenance Weber Spider Stopper GuardsMain Burner Flame Pattern Replacing Main BurnersTo reinstall the burners, reverse steps c through g Crossover Ignition System Operations Troubleshooting & Maintenance Page 13-14 10,14 Parts List MWARNINGFinal Word Thanks