Weber 2000 General Maintenance, Weber Spider Stopper Guards, Main Burner Flame Pattern

Page 25

General Maintenance

Weber Spider Stopper Guards

Your Weber Gas Barbecue, as well as any outdoor gas appliance, is a target for spiders and other insects. They can nest in the venturi section of the burner tubes. This blocks the normal gas flow, and can cause the gas to flow back out of the air shutter. Figure 4. This could result in a fire in and around the air shutters, under the control panel, causing serious damage to your barbecue.

Venturi

Main Burner Flame Pattern

The Weber Gas Barbecue burners have been factory set for the correct air and gas mixture. The correct flame pattern is shown in Figure 6.

Burner inside

Tips occasionally yellowish

cooking box

 

Light blue

Dark blue

Flames

Figure 6

Air shutter

Venturi fin

If the flames do not appear to be uniform the length of the burner tube, follow the burner cleaning procedures.

Figure 4

The Weber Spider Stopper Guard is factory installed. It fits tightly around the air shutter section of the burner tube and the valve, thereby preventing spiders and other insects access to the burner tubes through the air shutter openings. Figure 5.

Weber Spider

Stopper Guard

Figure 5

We recommend that you inspect the Weber Spider Stopper Guards at least once a year. (See section “Annual Maintenance”.) Also inspect and clean the Spider Stopper Guards if any of the following symptoms should ever occur.

1.The smell of gas in conjunction with the burner flames appearing yellow and lazy.

2.Barbecue does not reach temperature.

3.Barbecue heats unevenly.

4.One or more of the burners do not ignite.

mDANGER

Failure to correct these symptoms may result in a fire which can cause serious bodily injury or death and cause damage to property.

Main Burner Cleaning Procedure

Turn off the gas supply. Remove the manifold. (See Section “Replacing the main burners”.)

Look inside each burner with a flashlight. Figure 7.

Figure 7

Clean the inside of the burners with a wire (a straightened out coat hanger will work). Figure 8. Check and clean the air shutter opening at the ends of the burners. Check and clean the valve orifices at the base of the valves. Use a brass bristle brush to clean outside of burners. This is to make sure all the burner ports are fully open.

Figure 8

mCAUTION: Do not enlarge the burner ports when cleaning.

Replacing Main Burners

a)Your Weber Gas Barbecue must be OFF and cool.

b)Turn gas OFF at source.

c)Remove control panel: take off the burner control knobs. Remove the screws holding the control panel in place. Lift off the control panel.

25

Image 25
Contents Genesis 2000 Series LP GAS Units only MDANGER MWARNINGSWarranty Patents and Trademarks Contents Gas supply testing For Installation in CanadaGeneral Instructions StorageCheck package contents AssemblyStep Left hand slide bar assembly Check contents of hardware packs Assemble frame Assemble wheelsComplete frame assembly Continue frame assemblyInsert casters Add cooking box Install igniter Install manifold bracketGeneral Specifications for Piping Install gas supplyGas line piping Test connectionsConnect flexible hose to manifold Check that all burner valves are offMWARNING Do not ignite burners while leak checking Check for gas leaksInstall the bottom tray Install Flavorizer Bars and Cooking GratesInstall tool holders, control panel and burner control knobs Install the lidInstall swing table Complete accessory installation To Extinguish Lighting Manual Lighting Cooking Periodic CleaningStorage and/or Nonuse Inspection and Cleaning of the Weber Spider Stopper Guards Annual MaintenanceWeber Spider Stopper Guards General MaintenanceMain Burner Flame Pattern Replacing Main BurnersTo reinstall the burners, reverse steps c through g Crossover Ignition System Operations Troubleshooting & Maintenance Page 13-14 10,14 MWARNING Parts ListFinal Word Thanks