Panasonic CS-S22NKU-1, CS-S18NKU-1, CS-S12NKUW-1, CS-S9NKUW-1, CU-S9NKU-1 Table of Contents

Page 2

TABLE OF CONTENTS

1.

Safety Precautions

3

2.

Specification

5

3.

Location of Controls and Components

9

 

3.1

Indoor Unit

9

 

3.2

Outdoor Unit

9

 

3.3

Remote Control

9

4.

Dimensions

10

 

4.1

Indoor Unit

10

 

4.2

Outdoor Unit

12

5.

Refrigeration Cycle Diagram

13

 

5.1

CS-S9NKUW-1 CU-S9NKU-1

 

 

 

CS-S12NKUW-1 CU-S12NKU-1

13

 

5.2

CS-S18NKU-1 CU-S18NKU-1

 

 

 

CS-S22NKU-1 CU-S22NKU-1

14

6.

Block Diagram

15

6.1CS-S9NKUW-1 CU-S9NKU-1

 

 

CS-S12NKUW-1 CU-S12NKU-1

................15

 

6.2

CS-S18NKU-1 CU-S18NKU-1

 

 

 

CS-S22NKU-1 CU-S22NKU-1

16

7.

Wiring Connection Diagram

17

 

7.1

Indoor Unit

17

 

7.2

Outdoor Unit

19

8.

Electronic Circuit Diagram

22

 

8.1

Indoor Unit

22

 

8.2

Outdoor Unit

24

9.

Printed Circuit Board

27

 

9.1

Indoor Unit

27

 

9.2

Outdoor Unit

29

10. Installation Instruction

31

 

10.1

S9NKUW-1 S12NKUW-1

31

 

10.2

S18NKU-1 S22NKU-1

39

11. Operation Control

47

 

11.1

Basic Function

47

 

11.2

Indoor Fan Motor Operation

48

11.3Outdoor Fan Motor Operation

(For S9NK and S12NK)

..............................48

11.4Outdoor Fan Motor Operation

(For S18NK and S22NK)

............................48

11.5 Airflow Direction

48

11.6Quiet Operation (Cooling Mode/Cooling Area

 

of Dry Mode)

49

11.7

Powerful Mode Operation

50

11.8

Timer Control

50

11.9

Random Auto Restart Control

50

11.10

Indication Panel

51

12. Protection Control

52

12.1Restart Control (Time Delay Safety Control)..

....................................................................52

12.2

30 Seconds Forced Operation

...................52

12.3

Total Running Current Control

...................52

12.4IPM (Power Transistor) Prevention Control52

12.5Compressor Overheating Prevention Control

(For S18, S22NK only)

53

12.6Low Pressure Protection Control (Gas

 

Leakage Detection)

53

12.7

Low Frequency Protection Control 1

53

12.8

Low Frequency Protection Control 2

53

12.9

Outdoor Air Temperature Control

54

12.10

Cooling Overload Control

54

12.11

Freeze Prevention Control

54

12.12

Freeze Prevention Control 2

54

12.13

Dew Prevention Control

54

13. Servicing Mode

55

13.1

Auto Off/On Button

55

13.2

Remote Control Button

56

14. Troubleshooting Guide

57

14.1

Refrigeration Cycle System

57

14.2

Breakdown Self Diagnosis Function

59

14.3

Error Code Table

60

14.4

Troubleshooting Flowchart

61

15. Disassembly and Assembly Instructions

84

15.1Indoor Electronic Controllers, Cross Flow

 

Fan and Indoor Fan Motor Removal

 

 

Procedures

84

16. Technical Data

88

16.1

Operation Characteristics

88

17. Exploded View and Replacement Parts List. 96

17.1

Indoor Unit

96

17.2

Outdoor Unit

100

2

Image 2
Contents CS-S18NKU-1 CU-S18NKU-1 CS-S22NKU-1 CU-S22NKU-1 Indoor Unit Outdoor UnitCU-S12NKU-1 Table of Contents Safety Precautions Items to be followed are classified by the symbolsPage Specification CU-S9NKU-1 CU-S12NKU-1 ARIDRY Bulb WET Bulb CS-S18NKU-1 CS-S22NKU-1 Piping Indoor Unit Outdoor Unit Remote Control Location of Controls and ComponentsCS-S9NKUW-1 CS-S12NKUW-1 DimensionsIndoor Unit CS-S18NKU-1 CS-S22NKU-1 CU-S9NKU-1 CU-S12NKU-1 CU-S18NKU-1 CU-S22NKU-1 Refrigeration Cycle Diagram CS-S18NKU-1 CU-S18NKU-1 CS-S22NKU-1 CU-S22NKU-1 Block Diagram CS-S18NKU-1 CU-S18NKU-1 CS-S22NKU-1 CU-S22NKU-1 Wiring Connection Diagram CS-S18NKU-1 CS-S22NKU-1 CU-S9NKU-1 CU-S12NKU-1 CU-S18NKU-1 CU-S22NKU-1 Electronic Circuit Diagram CS-S18NKU-1 CS-S22NKU-1 Outdoor Unit CU-S18NKU-1 CU-S22NKU-1 Printed Circuit Board Main Printed Circuit BoardPower Printed Circuit Board Indicator Printed Circuit Board CU-S9NKU-1 CU-S12NKU-1 CU-S18NKU-1 CU-S22NKU-1 10.1 S9NKUW-1 S12NKUW-1 Installation InstructionIndoor/Outdoor Unit Installation Diagram Select the Best LocationHow to Fix Installation Plate Indoor UnitThis can be used for left rear piping and bottom piping also Connect the Cable to the Indoor Unit Page Install the Outdoor Unit Outdoor UnitGas leak checking Piping Insulation 10.2 S18NKU-1 S22NKU-1 How to Fix Installation Plate This can be used for left rear piping and bottom piping also Connect the Cable to the Indoor Unit Page Model S18NKU-1 Evacuation of the equipment Piping Insulation Basic Function Internal Setting TemperatureOperation Control Cooling OperationOutdoor Fan Motor Operation For S18NK and S22NK Indoor Fan Motor OperationOutdoor Fan Motor Operation For S9NK and S12NK Airflow DirectionHorizontal Airflow Quiet Operation Cooling Mode/Cooling Area of Dry Mode11.5.1 Vertical Airflow On Timer Control Powerful Mode OperationTimer Control OFF Timer ControlLED Power Timer Quiet Powerful Indication PanelProtection Control Restart Control Time Delay Safety ControlIPM Power Transistor Prevention Control 12.2 30 Seconds Forced Operation12.4.2 S18NK, S22NK Low Pressure Protection Control Gas Leakage DetectionLow Frequency Protection Control Freeze Prevention Control Outdoor Air Temperature ControlCooling Overload Control Dew Prevention ControlServicing Mode Auto Off/On ButtonReset AC Remote Control ButtonReset RC TimerTroubleshooting Guide Refrigeration Cycle SystemCondition Cooling Mode Air conditioner Self Diagnosis Function Three Digits Alphanumeric Code To Display Memorized Error Code Protective OperationBreakdown Self Diagnosis Function To Make a DiagnosisError Code Table Abnormality / Protection controlTroubleshooting Flowchart 14.4.1 H11 Indoor/Outdoor Abnormal Communication14.4.2 H12 Indoor/Outdoor Capacity Rank Mismatched 14.4.3 H14 Indoor Intake Air Temperature Sensor Abnormality 14.4.4 H15 Compressor Temperature Sensor Abnormality 14.4.5 H16 Outdoor Current Transformer Open Circuit 14.4.6 H19 Indoor Fan Motor DC Motor Mechanism Locked 14.4.7 H23 Indoor Pipe Temperature Sensor Abnormality 14.4.8 H27 Outdoor Air Temperature Sensor Abnormality 14.4.9 H28 Outdoor Pipe Temperature Sensor Abnormality Malfunction Decision Conditions 14.4.11 H33 Unspecified Voltage between Indoor and Outdoor 14.4.12 H97 Outdoor Fan Motor DC Motor Mechanism Locked 14.4.13 H98 Indoor High Pressure Protection Malfunction Decision Conditions 14.4.15 F11 Indoor Pipe Temperature Sensor Abnormality 14.4.16 F90 Power Factor Correction Protection 14.4.17 F91 Refrigeration Cycle Abnormality 14.4.18 F93 Compressor Rotation Failure 14.4.19 F95 Cooling High Pressure Abnormality 14.4.20 F96 IPM Overheating 14.4.21 F97 Compressor Overheating 14.4.22 F98 Input Over Current Detection 14.4.23 F99 Output Over Current Detection Disassembly and Assembly Instructions To remove front grilleTo remove discharge grille Page Page CS-S9NKUW-1 CU-S9NKU-1 Technical DataOperation Characteristics Page CS-S12NKUW-1 CU-S12NKU-1 Page CS-S18NKU-1 CU-S18NKU-1 Page CS-S22NKU-1 CU-S22NKU-1 Page Exploded View and Replacement Parts List CS-S12NKUW-1 Remark CS-S18NKU-1 CS-S22NKU-1 CS-S22NKU-1 Remark Outdoor Unit CU-S12NKU-1 Remark CU-S18NKU-1 CU-S22NKU-1 CU-S22NKU-1 Remark
Related manuals
Manual 103 pages 20.36 Kb