Panasonic CS-S9NKUW-1, CS-S18NKU-1, CS-S12NKUW-1, CU-S9NKU-1, CU-S12NKU-1 CS-S22NKU-1 Remark

Page 99

REF. NO.

PART NAME & DESCRIPTION

1CHASSIS COMPLETE

2FAN MOTOR

3CROSS-FLOW FAN COMPLETE

4BEARING ASSY

5SCREW - CROSS-FLOW FAN

7EVAPORATOR

8FLARE NUT (LIQUID)

9FLARE NUT (GAS)

11 CLIP FOR SENSOR

12 CONTROL BOARD CASING

13 TERMINAL BOARD COMPLETE

14 ELECTRONIC CONTROLLER - MAIN

15 ELECTRONIC CONTROLLER - POWER

17 ELECTRONIC CONTROLLER - INDICATOR

19 SENSOR COMPLETE

20 CONTROL BOARD TOP COVER

21 INDICATOR HOLDER

22 CONTROL BOARD FRONT COVER CO.

23 DISCHARGE GRILLE COMPLETE

24FULCRUM

25VERTICAL VANE

26CONNECTING BAR

27CONNECTING BAR

28CONNECTING BAR

29CONNECTING BAR

30CONNECTING BAR

31AIR SWING MOTOR

32AIR SWING MOTOR

34CAP - DRAIN TRAY

35HORIZONTAL VANE COMPLETE

36BACK COVER CHASSIS

37REMOTE CONTROL COMPLETE

38FRONT GRILLE COMPLETE

39INTAKE GRILLE COMPLETE

40GRILLE DOOR COMPLETE

41AIR FILTER

42SCREW - FRONT GRILLE

43CAP - FRONT GRILLE

44DRAIN HOSE

45INSTALLATION PLATE

46BAG COMPLETE - INSTALLATION SCREW

47OPERATING INSTRUCTION

48INSTALLATION INSTRUCTION

49WIRE NET

50AIR PURIFYING FILTER

51BAG

52SHOCK ABSORBER (L)

53SHOCK ABSORBER (R)

54C.C.CASE

QTY.

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

15

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

3

3

1

1

1

1

1

1

1

1

1

1

1

CS-S18NKU-1

CWD50C1637

L6CBYYYL0056

CWH02C1077

CWH64K007

CWH551146

CWB30C3771

CWT251030

CWT251032

CWH32143

CWH102370A

CWA28C2357

CWA73C6143

CWA745811

CWA745740

CWA50C2135

CWH131350

CWD933021

CWH13C1201

CWE20C3049

CWH621103

CWE241289

CWE261156

CWE261158

CWE261157

CWE261159

CWE261160

CWA98K1014

CWA981241

CWH521096

CWE24C1295

CWD933031B

CWA75C3582

CWE11C4514

CWE22C1483

CWE14C1029

CWD001283

XTT4+16CFJ

CWH521194

CWH851173

CWH361098

CWH82C1705

CWF568314

CWF615166

CWD041145A

CWD00C1141

CWG861498

CWG713033

CWG713034

CWG565069

CS-S22NKU-1

REMARK

 

O

 

 

 

 

 

 

 

CWB30C3772

 

 

CWT251033

 

 

 

 

 

O

 

 

CWA73C6144

O

O

O

 

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

O

 

 

 

 

 

O

 

 

O

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Note)

All parts are supplied from PHAAM, Malaysia (Vendor Code: 00029488).

“O” marked parts are recommended to be kept in stock.

99

Image 99
Contents Indoor Unit Outdoor Unit CU-S12NKU-1CS-S18NKU-1 CU-S18NKU-1 CS-S22NKU-1 CU-S22NKU-1 Table of Contents Items to be followed are classified by the symbols Safety PrecautionsPage CU-S9NKU-1 CU-S12NKU-1 ARI SpecificationDRY Bulb WET Bulb CS-S18NKU-1 CS-S22NKU-1 Piping Location of Controls and Components Indoor Unit Outdoor Unit Remote ControlDimensions Indoor UnitCS-S9NKUW-1 CS-S12NKUW-1 CS-S18NKU-1 CS-S22NKU-1 CU-S9NKU-1 CU-S12NKU-1 CU-S18NKU-1 CU-S22NKU-1 Refrigeration Cycle Diagram CS-S18NKU-1 CU-S18NKU-1 CS-S22NKU-1 CU-S22NKU-1 Block Diagram CS-S18NKU-1 CU-S18NKU-1 CS-S22NKU-1 CU-S22NKU-1 Wiring Connection Diagram CS-S18NKU-1 CS-S22NKU-1 CU-S9NKU-1 CU-S12NKU-1 CU-S18NKU-1 CU-S22NKU-1 Electronic Circuit Diagram CS-S18NKU-1 CS-S22NKU-1 Outdoor Unit CU-S18NKU-1 CU-S22NKU-1 Main Printed Circuit Board Printed Circuit BoardPower Printed Circuit Board Indicator Printed Circuit Board CU-S9NKU-1 CU-S12NKU-1 CU-S18NKU-1 CU-S22NKU-1 Select the Best Location Installation InstructionIndoor/Outdoor Unit Installation Diagram 10.1 S9NKUW-1 S12NKUW-1Indoor Unit How to Fix Installation PlateThis can be used for left rear piping and bottom piping also Connect the Cable to the Indoor Unit Page Outdoor Unit Install the Outdoor UnitGas leak checking Piping Insulation 10.2 S18NKU-1 S22NKU-1 How to Fix Installation Plate This can be used for left rear piping and bottom piping also Connect the Cable to the Indoor Unit Page Model S18NKU-1 Evacuation of the equipment Piping Insulation Cooling Operation Internal Setting TemperatureOperation Control Basic FunctionAirflow Direction Indoor Fan Motor OperationOutdoor Fan Motor Operation For S9NK and S12NK Outdoor Fan Motor Operation For S18NK and S22NKQuiet Operation Cooling Mode/Cooling Area of Dry Mode 11.5.1 Vertical AirflowHorizontal Airflow OFF Timer Control Powerful Mode OperationTimer Control On Timer ControlIndication Panel LED Power Timer Quiet Powerful12.2 30 Seconds Forced Operation Restart Control Time Delay Safety ControlIPM Power Transistor Prevention Control Protection ControlLow Pressure Protection Control Gas Leakage Detection Low Frequency Protection Control12.4.2 S18NK, S22NK Dew Prevention Control Outdoor Air Temperature ControlCooling Overload Control Freeze Prevention ControlAuto Off/On Button Servicing ModeTimer Remote Control ButtonReset RC Reset ACRefrigeration Cycle System Troubleshooting GuideCondition Cooling Mode Air conditioner To Make a Diagnosis To Display Memorized Error Code Protective OperationBreakdown Self Diagnosis Function Self Diagnosis Function Three Digits Alphanumeric CodeAbnormality / Protection control Error Code Table14.4.1 H11 Indoor/Outdoor Abnormal Communication Troubleshooting Flowchart14.4.2 H12 Indoor/Outdoor Capacity Rank Mismatched 14.4.3 H14 Indoor Intake Air Temperature Sensor Abnormality 14.4.4 H15 Compressor Temperature Sensor Abnormality 14.4.5 H16 Outdoor Current Transformer Open Circuit 14.4.6 H19 Indoor Fan Motor DC Motor Mechanism Locked 14.4.7 H23 Indoor Pipe Temperature Sensor Abnormality 14.4.8 H27 Outdoor Air Temperature Sensor Abnormality 14.4.9 H28 Outdoor Pipe Temperature Sensor Abnormality Malfunction Decision Conditions 14.4.11 H33 Unspecified Voltage between Indoor and Outdoor 14.4.12 H97 Outdoor Fan Motor DC Motor Mechanism Locked 14.4.13 H98 Indoor High Pressure Protection Malfunction Decision Conditions 14.4.15 F11 Indoor Pipe Temperature Sensor Abnormality 14.4.16 F90 Power Factor Correction Protection 14.4.17 F91 Refrigeration Cycle Abnormality 14.4.18 F93 Compressor Rotation Failure 14.4.19 F95 Cooling High Pressure Abnormality 14.4.20 F96 IPM Overheating 14.4.21 F97 Compressor Overheating 14.4.22 F98 Input Over Current Detection 14.4.23 F99 Output Over Current Detection To remove front grille Disassembly and Assembly InstructionsTo remove discharge grille Page Page Technical Data Operation CharacteristicsCS-S9NKUW-1 CU-S9NKU-1 Page CS-S12NKUW-1 CU-S12NKU-1 Page CS-S18NKU-1 CU-S18NKU-1 Page CS-S22NKU-1 CU-S22NKU-1 Page Exploded View and Replacement Parts List CS-S12NKUW-1 Remark CS-S18NKU-1 CS-S22NKU-1 CS-S22NKU-1 Remark Outdoor Unit CU-S12NKU-1 Remark CU-S18NKU-1 CU-S22NKU-1 CU-S22NKU-1 Remark
Related manuals
Manual 103 pages 20.36 Kb

CS-S9NKUW-1, CS-S22NKU-1, CU-S18NKU-1, CS-S18NKU-1, CS-S12NKUW-1 specifications

Panasonic has long been a leader in the HVAC industry, and its latest range of air conditioning units—including the CU-S9NKU-1, CU-S12NKU-1, CU-S22NKU-1, CS-S12NKUW-1, and CS-S18NKU-1—showcases innovative features and robust technologies designed to enhance home comfort while reducing energy consumption.

The CU-S9NKU-1 model is notable for its compact design, making it ideal for smaller spaces without sacrificing performance. It boasts advanced inverter technology, enabling precise temperature control and energy efficiency. The built-in air purification system ensures that indoor air quality remains high, filtering out allergens and pollutants.

Similarly, the CU-S12NKU-1 variant provides a balance of power and efficiency for medium-sized rooms. This model incorporates a quiet operation feature, making it a perfect choice for bedrooms and living areas where noise levels need to be minimized. The adjustable airflow louvers ensure that air is distributed evenly throughout the space.

For larger spaces, the CU-S22NKU-1 stands out with its high cooling and heating capacity. This model is equipped with a dual inverter compressor that enhances both efficiency and performance, providing rapid cooling or heating when needed. The user-friendly remote control and smart connectivity options allow homeowners to adjust settings conveniently, even when they’re away from home.

The CS-S12NKUW-1 model features a sleek design and additional functionalities like the Eco Mode and Sleep Mode. Eco Mode adjusts the power consumption based on the user’s preferences, while Sleep Mode operates at low noise levels, promoting a restful environment during nighttime hours.

Lastly, the CS-S18NKU-1 combines innovative technology with aesthetic appeal. Its modern design is meant to complement contemporary interiors, and its high seasonal energy efficiency ratio (SEER) indicates strong performance in cooling seasons. Additionally, this model includes several energy-saving modes that adapt to changing thermal loads, ensuring that energy wastage is minimized.

Overall, Panasonic’s CU and CS series air conditioning units offer an impressive blend of technology and design, making them suitable for various needs and spaces while focusing on energy efficiency and user comfort. Whether for residential or light commercial use, these models provide reliable, effective solutions for climate control.