14.3 | Error Code Table |
|
| ||
Diagnosis | Abnormality / Protection control | Abnormality Judgment | Emergency | ||
display | Operation | ||||
|
| ||||
H00 |
| No abnormality detected | - | Normal operation | |
H11 |
| Indoor / Outdoor abnormal | > 1 min after starting | Indoor fan operation | |
| communication | operation | only | ||
|
| ||||
H12 |
| Connection capability rank abnormality | Continuously for 90 sec | - | |
| after power supplied | ||||
|
|
|
| ||
H14 |
| Indoor intake air temperature sensor | Continue for 5 sec. | - | |
| abnormality | ||||
|
|
|
| ||
H15 |
| Outdoor compressor temperature sensor | Continue for 5 sec. | - | |
| abnormality | ||||
|
|
|
| ||
H16 |
| Outdoor current transformer open circuit | - | - | |
|
|
|
|
| |
H19 |
| Indoor fan motor mechanism locked | 7 occurrences | - | |
| continuously | ||||
|
|
|
| ||
H23 |
| Indoor heat exchanger temperature | Continue for 5 sec. | ○ | |
| sensor abnormality |
| |||
|
|
|
| ||
H27 |
| Outdoor air temperature sensor | Continue for 5 sec. | ○ | |
| abnormality |
| |||
|
|
|
| ||
H28 |
| Outdoor heat exchanger temperature | Continue for 5 sec. | ○ | |
| sensor abnormality |
| |||
|
|
|
| ||
|
|
|
|
| |
H30 |
| Discharge temperature sensor | Continue for 5 sec. |
| |
| abnormality |
| |||
|
|
|
| ||
H33 |
| Indoor / outdoor wrong connection | - | - | |
H38 |
| Indoor / outdoor mismatch (brand code) | - | - | |
H64 |
| Outdoor high pressure sensor | Continue for 1 minutes | - | |
| abnormality | ||||
|
|
|
| ||
H97 |
| Outdoor fan lock abnormality | 2 occurrences within 30 |
| |
|
| minutes |
| ||
|
|
|
| ||
H98 |
| Indoor temperature rise abnormality | - | - | |
|
|
|
|
| |
H99 |
| Indoor heat exchanger freeze prevention | - | - | |
| protection | ||||
|
|
|
| ||
F11 |
| 4 way valve switching failure * | 4 occurrences within 30 | - | |
| minutes | ||||
|
|
|
| ||
F17 |
| Indoor standby units freezing abnormality | 3 times happen within | - | |
| 40 minutes | ||||
|
|
|
| ||
|
|
|
|
| |
F90 |
| System and compressor microcomputer | 2 occurrences within 5 | - | |
| communication error(for S10*** only) | seconds | |||
|
|
| |||
F90 |
| Power factor correction abnormality | 4 occurrences within 20 | - | |
| minutes | ||||
|
|
|
| ||
F91 |
| Refrigerant cycle abnormal | 2 occurrences within 20 | - | |
| minutes | ||||
|
|
|
| ||
F93 |
| Outdoor compressor abnormal revolution | 4 occurrences within 20 | - | |
| minutes | ||||
|
|
|
| ||
F95 |
| Cooling high pressure protection | 4 occurrences within 20 | - | |
| minutes | ||||
|
|
|
| ||
F96 |
| Intelligent power transistor overheating | - | - | |
| protection | ||||
|
|
|
| ||
|
|
|
|
| |
F97 |
| Compressor temperature rise protection | 4 times occurrence within | - | |
| control | 20 minutes | |||
|
|
| |||
F98 |
| Total running current protection | 3 times occurrence within | - | |
| 20 minutes | ||||
|
|
|
| ||
F99 |
| Outdoor direct current (DC) peak | 7 times occurrence | - | |
| detection | continuously | |||
|
|
| |||
|
|
|
|
|
Primary location to verify
•Internal / external cable connection
•Indoor / outdoor PCB
-
•Intake air temperature sensor (defective or disconnected)
•Compressor temperature sensor (defective or disconnected)
•Outdoor PCB
•IPM (Power transistor) module
•Indoor PCB
•Fan motor
•Heat exchanger temperature sensor (defective or disconnected)
•Outdoor temperature sensor (defective or disconnected)
•Outdoor heat exchanger temperature sensor (defective or disconnected)
•Outdoor discharge temperature sensor (defective or disconnected)
•Indoor / outdoor supply voltage
-
•High pressure sensor
•Lead wire and connector
•Outdoor fan motor locked
•Air filter dirty
•Air circulation short circuit
•Insufficient refrigerant
•Air filter dirty
•
•
•Check indoor/outdoor connection wire and pipe
•Indoor heat exchanger sensor lead wire and connector
•Expansion valve lead wire and connector.
•Compressor
•Outdoor PCB
•Outdoor PCB
•No refrigerant (
•Outdoor compressor
•Outdoor refrigerant circuit
•Excess refrigerant
•Improper heat radiation
•IPM (Power transistor)
•Insufficient refrigerant
•Compressor
•Excess refrigerant
•Improper heat radiation
•Outdoor PCB
•IPM (Power transistor)
•Compressor
Note:
“○” – Frequency measured and fan speed fixed
“* ”– For cooling only model, it is the indication when indoor heat exchanger sensor or indoor air intake sensor has abnormality.
The memory data of error code is erased when the power supply is cut off, or press the Auto Switch until “beep” sound heard following by pressing the CHECK button at remote control.
Although operation forced to stop when abnormality detected, emergency operation is possible for certain errors (refer to Error Code Table) by using remote control or Auto OFF/ON button at indoor unit. However, the remote control signal receiving sound is changed from one “beep” to four “beep” sounds.