Panasonic CU-XE12EKE, CS-XE9EKE, CS-XE12EKE, CU-XE9EKE manual Auto Filter Cleaning

Page 7

AUTO FILTER CLEANING

Filter Cleaning Indicator

AUTO

Filter cleaning will run automatically after the air conditioner operation stops (air conditioner is turned off using remote control).

After the filter cleaning is completed, the air conditioner operation will remain off.

AIR CONDITIONER TIMER

Filter cleaning will run automatically after the air conditioner operation stops (air conditioner is turned off by the air conditioner timer).

After the filter cleaning is completed, the air conditioner operation will remain off.

FORCE CLEANING

Once the air conditioner operation time exceeds 24 hours, the unit is forced to run filter cleaning.

After the filter cleaning is completed, the air conditioner operation will resume automatically.

About

Filter cleaning

The filter cleaning indicator light will move to left or right when filter cleaning is in progress.

Filter cleaning in progress will be cancelled if:

-Certain button on the remote control are pressed.

-The air conditioner main unit’s movable front panel is lifted up.

-There is a power failure.

ENGLISH

Troubleshooting

Timer indicator is blinking and error code H51 is revealed on the display.

Timer indicator is blinking and error code H52 is revealed on the display.

The filter cleaning device is jammed because the filter is not installed correctly.

The filter cleaning device is malfunction.

The filter cleaning device is malfunction.

Printed circuit board is malfunction.

Note :

To reveal the error code, please refer to Product Overview’s troubleshooting-error code checking.

The condition above does not affect the unit’s operation.

In case of malfunction, please consult your nearest authorized dealer.

7

Image 7
Contents Operating Instructions Air Conditioner Definition Safety PrecautionsOperation Condition Regulatory InformationAuto OFF/ON Button IndicatorProduct Overview AboutRemote Control Signal Remote Control PreparationFilter cleaning Intro to Filter CleaningAuto Filter Cleaning Hint Timer Filter CleaningManual Filter Cleaning Manual Filter CleaningHear 3 continuous beeps SettingDisable Filter Cleaning You will hear 1 beepCool Cooling Operation Operation DetailsAuto Automatic Operation Heat Heating OperationVentilation Select your desired ventilation settingOperations Details FAN SPEED, AIR SwingTo enable Quiet Powerful Operation POWERFUL, QuietTimer Wipe gently Care & MaintenanceWashing Instructions Raise and pull to remove Wash gently and dryDetach the filter gently Pull the air filter towards youHints Inspecção Sazonal Após UM Período DE Inactividade Prolongado NON Serviceable Criterias F565101 OPSC0601-02