Bosch Appliances F.01U.252.722 List of criteria, Criterion Number Alarm a or Event E Comment

Page 33

NurseCall Relay Unit en 33

A.4

List of criteria

 

 

 

 

 

 

Criterion

 

Number

Alarm (A) or Event (E)

Comment

 

 

 

 

 

ERROR

 

00

A

System malfunction, e.g. component defective

 

 

 

 

 

PERSONNEL A

 

01

E

Coded key active (N46)

 

 

 

 

 

LOW BATTERY

 

02

A

Battery at low level (Transmitter)

 

 

 

 

 

ACK. N46

 

03

E

Acknowledgement (Sent by N46, S35 or S37)

 

 

 

 

 

DOOR

 

04

E

Door open or door closed

 

 

 

 

 

TECHNICAL

 

05

A

Technical Call (N46)

 

 

 

 

 

PERSONNEL C

 

06

E

Coded key presence (N46)

 

 

 

 

 

HELP

 

07

A

Call for Help

 

 

 

 

 

UNKNOWN

 

08

E

Not used

 

 

 

 

 

END PERSONNEL

 

09

E

Removed coded key (N46)

 

 

 

 

 

PERSONNEL D

 

10

E

Coded key presence (N46)

 

 

 

 

 

ASSISTANCE

 

11

A

Assistance Call

 

 

 

 

 

24 HOURS

 

12

E

Daily message check

 

 

 

 

 

RESERVE

 

13

A

Reserve Call (N46)

 

 

 

 

 

PERSONNEL B

 

14

E

Coded key presence (N46)

 

 

 

 

 

RADIO NOISE

 

15

E

Bad radio transmission (noise)

 

 

 

 

 

FIRE

 

16

A

Fire Alarm

 

 

 

 

 

ACK. TRANSM.1

 

17

E

Acknowledgement (Ack. Transmitter No. 1)

 

 

 

 

 

LOCAL ACK.

 

18

E

Local Acknowledgement (Main Unit or Relay Unit)

 

 

 

 

 

POWER OUTAGE

 

19

E

Main Unit or Relay Unit not powered

 

 

 

 

 

POWER BACK

 

20

E

Power back (Main Unit or Relay Unit)

 

 

 

 

 

COMPUTER OFF

 

21

E

Alarm management PC off

 

 

 

 

 

COMPUTER ON

 

22

E

Alarm management PC on

 

 

 

 

 

BAT.ACK.TRANSM

 

23

E

Battery at low level (One of the Ack. Transmitter)

 

 

 

 

 

RELAY ON

 

24

E

Relay Unit connected on RS-485 Bus

 

 

 

 

 

RELAY OFF

 

25

A

Relay Unit disconnected from RS-485 Bus

 

 

 

 

 

NO RELAY

 

26

E

Relay Unit off acknowledged (Main Unit)

 

 

 

 

 

LOW ACCU

 

27

E

Accumulator discharged (Main Unit or Relay Unit)

 

 

 

 

 

ACK. TRANSM.2

 

28

E

Acknowledgement (Ack. Transmitter No. 2)

 

 

 

 

 

ACK. TRANSM.3

 

29

E

Acknowledgement (Ack. Transmitter No. 3)

 

 

 

 

 

ACK. TRANSM.4

 

30

E

Acknowledgement (Ack. Transmitter No. 4)

 

 

 

 

 

ACK. TRANSM.5

 

31

E

Acknowledgement (Ack. Transmitter No. 5)

 

 

 

 

 

ACK. TRANSM.xx

 

xx

E

Acknowledgement (Ack. Transmitter No. xx)

 

 

 

 

 

ACK. TRANSM.32

 

58

E

Acknowledgement (Ack. Transmitter No. 32)

 

 

 

 

 

DEMENTIA

 

60

A

Dementia Alarm

 

 

 

 

 

NOTICE!

All events are buffered into the event buffer of the NurseCall Relay Unit. All alarms and events are sent to the printer/display. All alarms and events except the events "COMPUTER OFF" and "COMPUTER ON" are sent to the Alarm management Software.

Bosch Security Systems

User Manual

F.01U.252.722 V1 2011.12

Image 33 Contents
NurseCall Relay Unit Page Table of Contents Operation MaintenanceDisposal AppendixImportance of safety instructions Safety instructionsDisregarding safety rules General safety instructions1Observation and information General description DescriptionTop view Yellow buttonBottom view Front view Relay Unit rear viewStatus NurseCall Relay Unit V2.02 BN111.242.00A Detailed descriptionLoudspeaker DisplayKeys Function 4RS-485 interface 5AntennaRelay output 3Installation List of contents1Unpacking Installation on a piece of furniture InstallationWall installation Installing the antennaConnecting to the mains Disassemble the unit see .5.1 Disassembling the unit, 7Connecting the RS-485 Incorrect connectionCorrect connection Setting the 100 Ohm termination jumper 8Connecting the RS-232 to the Relay Plus UnitGeneralities ProgrammingDate TimeLocating ? First useOFF / on Relay Unit ID · +Special settings Relay Unit OFFAssistance & Fire Priority Assistance & Fire Nonpriority Printer/display setup on the Relay Plus UnitMultitone Texte BAD/WC + HILFE-2 Standardtexte Technik + NOTRUF2Display Zettler ¬ Display ZettlerCriter + 1 Spaces Display Norsk ¬ Display Norsk Rota.of AlarmsYES ¡Display ffrrrb FL 2 +RO 3 +BE1 Selection Display NorskAdjusting the loudspeaker volume Consulting the alarm or event buffer5Operation Display indications Switching between alarm and event buffers indicationFirst information block Second information blockHelp Local ACKMonitoring the power supply 6MaintenanceMonitoring the backup battery Checking the system Cleaning Parts replacement Disassembling the unit Backup battery replacing Important Safety InstructionsProcedure Battery DisassemblyDisposal Returning to the manufacturerElectrical specifications Dimensions and weightAAppendix List of criteria Criterion Number Alarm a or Event E CommentPower socket unit bottom ConnectorsLine socket unit bottom RS-232 socket Relay Plus Unit rearPage Bosch Security Systems