Bosch Appliances F.01U.252.722 user manual Switching between alarm and event buffers indication

Page 26

26 en OperationNurseCall Relay Unit

5.2.1

Switching between alarm and event buffers indication

 

 

The alarm buffer is indicated by default. If you are in the event buffer, the unit changes

 

automatically to the alarm buffer after 1 minute without activity.

 

 

If there are no entries in the alarm buffer, the display shows the actual date and time.

 

To switch from alarm to event buffer and vice versa, press

.

 

Scroll the alarms or the events with

and

.

 

 

Scroll the alarms only with the Green button.

 

 

5.2.2

Display indications

 

 

 

 

With the Yellow button, you can switch between three available information blocks.

 

The following information is displayed when an alarm or a message arrives:

First information block

In case of a "floor/room/bed" display mode:

1.criterion of the alarm or message

2.alarm (A) or event (E) followed by its order in the buffer

3.identification of the transmitter location (floor/room/bed numbers)

In case of "single number" display mode:

1.criterion of the alarm or message

2.alarm (A) or event (E) followed by its order in the buffer

3.identification of the transmitter location (three digits or four signs)

Second information block

4.date of the event;

5.time of the event;

6.main unit (space) or relay Unit (A...f) identification number;

7.quality of the received radio signal.

This information is visible in all display modes.

F.01U.252.722 V1 2011.12

User Manual

Bosch Security Systems

Image 26
Contents NurseCall Relay Unit Page Table of Contents Disposal MaintenanceOperation AppendixDisregarding safety rules Safety instructionsImportance of safety instructions General safety instructions1Observation and information Top view DescriptionGeneral description Yellow buttonBottom view Status Front viewRelay Unit rear view Loudspeaker Detailed descriptionNurseCall Relay Unit V2.02 BN111.242.00A DisplayKeys Function Relay output 4RS-485 interface5Antenna 1Unpacking 3InstallationList of contents Wall installation InstallationInstallation on a piece of furniture Installing the antennaConnecting to the mains Disassemble the unit see .5.1 Disassembling the unit, Correct connection 7Connecting the RS-485Incorrect connection 8Connecting the RS-232 to the Relay Plus Unit Setting the 100 Ohm termination jumperDate ProgrammingGeneralities TimeOFF / on First useLocating ? Relay Unit ID · +Assistance & Fire Priority Special settingsRelay Unit OFF Multitone Texte BAD/WC + HILFE-2 Printer/display setup on the Relay Plus UnitAssistance & Fire Nonpriority Standardtexte Technik + NOTRUF2Criter + 1 Spaces Display Zettler¬ Display Zettler Display ffrrrb FL 2 +RO 3 +BE1 ¬ Display Norsk Rota.of AlarmsYES ¡Display Norsk Selection Display Norsk5Operation Adjusting the loudspeaker volumeConsulting the alarm or event buffer First information block Switching between alarm and event buffers indicationDisplay indications Second information blockLocal ACK HelpMonitoring the backup battery 6MaintenanceMonitoring the power supply Checking the systemDisassembling the unit CleaningParts replacement Procedure Backup battery replacingImportant Safety Instructions Disposal DisassemblyBattery Returning to the manufacturerAAppendix Electrical specificationsDimensions and weight Criterion Number Alarm a or Event E Comment List of criteriaLine socket unit bottom ConnectorsPower socket unit bottom RS-232 socket Relay Plus Unit rearPage Bosch Security Systems

F.01U.252.722 specifications

The Bosch Appliances F.01U.252.722 represents a leap in modern home convenience, combining advanced technology with sleek design. This versatile appliance is primarily recognized as part of Bosch's high-quality line of kitchen products, gaining popularity due to its functionality and efficiency.

One of the standout features of the F.01U.252.722 is its energy efficiency. The appliance is designed to operate with minimal energy consumption, reflecting Bosch's commitment to sustainability. This not only helps the environment but also saves homeowners significantly on electricity bills. The energy-efficient design is complemented by a selection of smart features that offer enhanced usability.

In terms of functionality, this model boasts a range of smart technologies that make everyday tasks more manageable. It includes intuitive controls, allowing users to easily adjust settings, monitor performance, and even configure options via smartphone apps. This connectivity feature epitomizes Bosch's approach to integrating technology within the home, providing users with remote access and control over their appliances.

The F.01U.252.722 is also designed with durability in mind. Constructed from high-quality materials, it promises longevity and resilience, ideal for even the most demanding environments. The elegant design adds a touch of sophistication to any kitchen, making it not just a functional appliance but also a stylish addition to home decor.

Another key characteristic of the Bosch F.01U.252.722 is its user-centric design. The appliance features an intuitive interface and responsive controls, ensuring ease of operation for people of all ages. This thoughtful design consideration enhances user experience and makes the appliance accessible.

Additionally, the F.01U.252.722 includes various safety features, ensuring peace of mind for families. Built-in mechanisms prevent overheating and accidental mishaps, making it a reliable choice for any household.

In summary, the Bosch Appliances F.01U.252.722 combines energy efficiency, smart technology, durability, and user-friendly design to enhance the kitchen experience. Its innovative features not only streamline daily tasks but also ensure a sustainable approach to home appliance use. The F.01U.252.722 is an essential addition for anyone looking to elevate their kitchen's efficiency and style.