Panasonic CS-KS12NB41, CS-KS18NB4UW, CZ-18BT1U + CU-KS18NKUA, CZ-18BT1U + CU-KS12NK1A Indoor Unit

Page 15

2-1-5.Indoor Unit

CS-KS18NB4UW & CZ-18BT1U

 

 

 

Outdoor Unit CU-KS18NKUA

 

 

 

< 208V >

 

 

 

 

 

 

 

Voltage Rating

 

 

 

 

208V Single-Phase 60Hz

Performance

 

 

 

 

 

 

Cooling

Total Capacity

 

 

 

BTU/h

17,500

( 4,000 to 17,500 )

Air Circulation (Hi/Me/Lo)

ft3/min (m3/h)

341 (579) / 294 (500) / 253 (430)

 

 

 

 

 

kW

5.15

( 1.2 to 5.15 )

 

Sensible Capacity

 

 

 

BTU/h

 

10,600

 

Latent Capacity

 

 

 

BTU/h

 

6,900

 

 

 

 

 

 

 

 

Moisture Removal (High)

 

Pints/h

 

4.89

Rating

Available Voltage Range

 

V

 

187 to 253

Running Amperes

 

 

 

A

9.1

( 1.2 to 9.1 )

Power Input

 

 

 

W

1,860

( 250 to 1,860 )

 

 

 

 

Electrical

Power Factor

 

 

%

 

98

Compressor Locked Rotor Amperes

 

A

 

17.5

 

EER

 

 

 

BTU/h/W

 

9.41

 

SEER

 

 

 

BTU/Wh

 

16

 

 

 

 

 

 

 

 

Fuse or Circuit Breaker Capacity

 

A

 

15

 

Controls / Temperature Control

 

 

Microprocessor / I.C. Thermister

 

Control Unit

 

 

 

 

Wireless Remote Control Unit

 

Timer

 

 

 

 

24-Hour ON or OFF Timer, 1-Hour OFF Timer

 

Fan Speeds

 

Indoor / Outdoor

Auto and 3 steps / Auto (Hi and multi steps)

 

Airflow Direction (Indoor)

 

Horizontal

 

-

 

 

 

 

 

Vertical

 

Auto

Features

Air Filter

 

 

 

 

Washable, Anti-Mold

Refrigerant Control

 

 

 

 

Electric Expansion Valve

 

Compressor

 

 

 

 

DC Twin Rotary (Inverter)

 

Refrigerant / Amount charged at shipment

 

Ibs (g)

R410A / 2.87 (1,300)

 

 

 

 

 

 

 

 

 

Operation Sound

 

Indoor : Hi/Me/Lo

 

dB-A

 

44 / 40 / 36

 

 

 

Outdoor : Hi

 

dB-A

 

51

 

Refrigerant Tubing Connections

 

 

 

Flare Type

 

Max. allowable tubing length at shipment

 

ft (m)

 

25 (7.5)

 

Refrigerant

 

Narrow tube

 

inch (mm)

 

1/4 (6.35)

 

Tube Diameter

 

Wide tube

 

inch (mm)

 

1/2 (12.7)

 

Wired Remote Controller (Option)

 

 

 

CZ-RD515U

15

Image 15
Contents DC Inverter Split System AIR Conditioner Safety Precautions Prohibit Table of Contents Checking Electrical Components Operating Range Models CS-KS18NB4UW & CZ-18BT1U + CU-KS18NKUModels CS-KS12NB41 & CZ-18BT1U + CU-KS12NK1A Outdoor Unit SpecificationsUnit Specifications Indoor UnitDimensions & Weight Indoor Unit 208V Unit Dimensions Height Inch mm 12-5/16 Outdoor Unit CU-KS12NK1A CS-KS12NB41 & CZ-18BT1UCU-KS12NK1A Outdoor Unit CU-KS18NKUA 230V CU-KS18NKUA Indoor Unit Outdoor Unit CU-KS18NKUA 208V Indoor Unit Panel CZ-18BT1U Major Component SpecificationsIndoor Unit Indoor Unit Body CS-KS12NB41CB-CS-KS18NB4U Indoor Unit Body CS-KS18NB4UWOutdoor Unit CU-KS18NKU Outdoor UnitControl Circuit Fuse 125V 25A Outdoor Unit CU-KS18NKUA Other Component Specifications Unit inch mm Dimensional DataUnit inch mm 852-0-0010-12600-0 CU-KS18NKUA Refrigerant Flow Diagram Refrigerant Flow DiagramIndoor unit Outdoor unit Indoor Unit CS-KS18NB4UW & CZ-18BT1U Outdoor Unit CU-KS18NKUIndoor discharge air performance chart Temperature ChartsLow pressure performance chart Operating current performance chartTube Cooling Capacity Power Supply 115V Single Phase 60Hz Cooling CapacityPower Supply 230V Single Phase 60Hz Cooling Capacity CS-KS18NB4UW & CZ-18BT1UCU-KS18NKU or CU-KS18NKUA Cooling Capacity Low Ambient TC Total Cooling Capacity BTU/h Electrical Characteristics Electrical DataCooling Outdoor Unit Complete Unit Fan Motor CS-KS12NB41 18BT1U8FA2-5250-46900-2 Outdoor Unit CU-KS12NK1A 8FA2-5251-12300-2 BLK Outdoor Unit CU-KS18NKU CU-KS18NKUAAddress Setting of the Remote Controller MaintenanceHow to Connect How to DisconnectDisassembly Procedure Disconnect the connectors in the control boxRemove the air intake grill Remove the ceiling panel Remove the power box and control box Remove the indoor air temperature sensorScrew Ground cable CN07 CN03 CN09 CN06 Remove the main body lower section Remove the heat exchanger sensor Remove the drain pump and float switchRemove the heat exchanger Remove the turbo fan and fan motorPAM- control FunctionsOperation Functions Emergency operationLamp colors Timer backupCT Peak current cut-off control Compressor discharge temperature controlProtective Functions Freeze preventionTroubleshooting Before Calling for Service Precautions before Performing Inspection or RepairMethod of Self-Diagnostics Indoor Unit Self-diagnostics LampsReplace the circuit board or the fuse Using the TEST/T-RUN terminalsChecking the Indoor and Outdoor Units Replace the controllerCondition E01 Serial Communication Error Identification ProcedureOff Blinking Illuminated Before the OperationFrom the previous page a Condition E12 Indoor Fan Motor Trouble Diagnosis of Fan MotorOutdoor Fan Motor Noise Malfunction and Electromagnetic Interference Noise malfunctionElectromagnetic interference Measurement of Insulation Resistance for Electrical Parts Power Supply CordChecking Electrical Components Measurement of Insulation ResistanceChecking Continuity of Fuse on PCB Assy Characteristics Refrigerant R410A Special Precautions When Servicing UnitCharacteristics of New Refrigerant R410A What is New Refrigerant R410A?Checklist before Servicing Tools Specifically for R410A Tubing Installation ProceduresCase of Compressor Malfunction Procedure for Replacing CompressorAmount in the charging cylinder is less than 20% ExampleTo prevent the composition Case Refrigerant is Leaking Welding leaking pointsRecharging Use of Existing Units When Tubes are ExtendedCharging Additional Refrigerant Retro-Fitting Existing Systems

CZ-18BT1U + CU-KS18NKU, CZ-18BT1U + CU-KS12NK1A, CZ-18BT1U + CU-KS18NKUA, CS-KS18NB4UW, CS-KS12NB41 specifications

The Panasonic CZ-18BT1U indoor unit, when paired with the appropriate outdoor units like CU-KS18NKU, CU-KS18NKUA, CU-KS12NK1A, CS-KS18NB4UW, and CS-KS12NB41, offers a robust solution for maintaining optimal indoor climates. These units are designed for residential and commercial applications, ensuring reliable heating and cooling performance.

One of the standout features of the Panasonic CZ-18BT1U is its energy efficiency. This model boasts a high Seasonal Energy Efficiency Ratio (SEER), enabling users to enjoy a comfortable environment without incurring excessive energy costs. This is further complemented by advanced inverter technology, which allows for variable speed operation, adjusting the compressor activity based on the cooling or heating needs of the space. This feature not only enhances comfort but also minimizes energy consumption.

The outdoor unit options, CU-KS18NKU, CU-KS18NKUA, and CU-KS12NK1A, support this efficiency with high-performance compressors designed for reduced noise levels. They are built to withstand varied weather conditions, ensuring durability and longevity. The outdoor units also feature high-efficiency heat exchangers that improve thermal performance, enhancing overall system efficiency.

Noise reduction is a critical consideration in HVAC systems, and the Panasonic CS-KS18NB4UW and CS-KS12NB41 outdoor units are engineered with this in mind. They operate at low decibel levels, making them ideal for residential areas where noise can be a concern. Additionally, these units come equipped with a wide range of operational modes, such as cooling, heating, and dehumidification, providing users with year-round comfort.

Flexibility and installation convenience are enhanced by the compact design of both the indoor and outdoor units. This versatility allows for various placement options, making them suitable for different room layouts.

Moreover, these systems incorporate air purification technologies, which help to improve indoor air quality by filtering out pollutants. This feature is especially beneficial for users with allergies or respiratory conditions, ensuring a healthier living environment.

In summary, the Panasonic CZ-18BT1U paired with CU-KS18NKU, CU-KS18NKUA, CU-KS12NK1A, CS-KS18NB4UW, and CS-KS12NB41 units offer an efficient and quiet HVAC solution. With advanced technologies, energy-saving features, and health-oriented design, they are a smart investment for maintaining comfort and improving air quality in any indoor space.