Panasonic
CS-CE9JKE Location of Controls and Components, Indoor Unit Outdoor Unit Remote Control
Troubleshooting
Specification
Operation Characteristics
Install
Error codes
Refrigeration Cycle Diagram
Timer Control
Dimension
Reset RC
Safety Precautions
Page 12
4 Location of Controls and Components
4.1.
Indoor Unit
4.2.
Outdoor Unit
4.3.
Remote Control
12
Page 11
Page 13
Image 12
Page 11
Page 13
Contents
Table of Contents
Exploded View and Replacement Parts List
Safety Precautions
Page
Specifications
Model Indoor CS-CE9JKE Outdoor CU-CE9JKE
Type Propeller Fan Material Motor Type
Model Indoor CS-CE9JKE Outdoor CU-CE9JKE
Model Indoor CS-CE12JKE Outdoor CU-CE12JKE
Cool/Fan M3/min ft3/min
Model Indoor CS-CE12JKE Outdoor CU-CE12JKE
Features
Easy to use remote control Quality Improvement
Indoor Unit Outdoor Unit Remote Control
Location of Controls and Components
Dimensions
Indoor Unit
Outdoor Unit
Refrigeration Cycle Diagram
Block Diagram
Wiring Connection Diagram
Outdoor Unit
Electronic Circuit Diagram
Outdoor Unit
Printed Circuit Board
Main Printed Circuit Board
Power Printed Circuit Board Indicator Printed Circuit Board
Outdoor Unit
Installation Instruction
Indoor/Outdoor Unit Installation Diagram
Select the Best Location
Indoor Unit
How to Fix Installation Plate
To Drill a Hole in the Wall and Install Sleeve of Piping
Indoor Unit Installation
This can be used for left rear piping and bottom piping also
Connect the Cable to the Indoor Unit
Cutting and Flaring the Piping
Install the Outdoor Unit
Connect the Piping
Evacuation of the Equipment
Connect the Cable to the Outdoor Unit
Pipe Insulation
Operation and Control
Basic Function
Indoor Fan Motor Operation
Automatic Operation
Fan Operation
Outdoor Fan Motor Operation
Airflow Direction
Vertical Airflow
Timer Control
Auto Restart Control
Indication Panel
Protection Control
Protection Control For All Operations
Compressor Overheating Prevention Control
Low Pressure Prevention Control Gas Leakage Detection
Low Frequency Protection Control
Outdoor Air Temperature Control
Protection Control For Cooling & Soft Dry Operation
Cooling Overload Control
Freeze Prevention Control
Protection Control For Heating Operation
Servicing Mode
Auto OFF/ON Button
Remote Control Button
Reset RC
Reset AC
Timer
Troubleshooting Guide
Refrigeration Cycle System
Low Pressure High Pressure
Breakdown Self Diagnosis Function
Self Diagnosis Function Three Digits Alphanumeric Code
Error Codes Table
Protection control Judgement
Power source or compressor lock
Self-diagnosis Method
15.4.1. H11 Indoor/Outdoor Abnormal Communication
15.4.2. H14 Indoor Intake Air Temperature Sensor Abnormality
15.4.3. H15 Compressor Temperature Sensor Abnormality
15.4.4. H16 Outdoor Current Transformer Open Circuit
15.4.5. H19 Indoor Fan Motor DC Motor Mechanism Locked
15.4.6. H23 Indoor Pipe Temperature Sensor Abnormality
15.4.7. H27 Outdoor Air Temperature Sensor Abnormality
15.4.8. H28 Outdoor Pipe Temperature Sensor Abnormality
Malfunction Decision Conditions
15.4.10. H33 Unspecified Voltage between Indoor and Outdoor
15.4.11. H97 Outdoor Fan Motor DC Motor Mechanism Locked
15.4.12. H98 Indoor High Pressure Protection
Malfunction Caused
15.4.14. F11 4-way valve Abnormality
15.4.15. F90 Power Factor Correction Protection
15.4.16. F91 Refrigeration Cycle Abnormality
Multi Models Only
15.4.17. F93 Compressor Rotation Failure
15.4.18. F95 Cooling High Pressure Abnormality
15.4.19. F96 IPM Overheating
15.4.20. F97 Compressor Overheating
15.4.21. F98 Input Over Current Detection
15.4.22. F99 Output Over Current Detection
Disassembly and Assembly Instructions
To remove front grille To remove power electronic controller
To remove discharge grille
Page
Page
Outdoor Electronic Controller Removal Procedure
Technical Data
Operation Characteristics
CU-CE9JKE
Page
Page
Page
CU-CE12JKE
Page
Page
Page
Sensible Capacity Chart
CU-CE12JKE
Exploded View and Replacement Parts List
Chassy Complete
Outdoor Unit
Chassy ASS’Y
Related pages
All Remote control page
Remote Control for Black Box AVSW-HDMI-RX
Using the Virtual Remote Control for Polycom 3725-64325-005
Remote Control Operation for Teac W-860R
Remote Control for NAD T534
Remote Control Receptor Remote Sensor for Denon 270
Component Names Remote Control for Hitachi UT37V702
Overview of the remote control for Philips PD9000/05
Remote control Mando a distancia for Samsung SCD27/D29
Conectores Remote Control for Marantz NR1605
Effective Distance of the Remote Control for Memorex MVR4041
What maintenance tips are available for the
Agilent 66332A dynamic model
?
Top
Page
Image
Contents