Panasonic CS-CE9JKE specifications Chassy Complete

Page 82

REF. NO.

PART NAME & DESCRIPTION

QTY.

CS-CE9JKE

CS-CE12JKE

REMARKS

 

 

 

 

 

 

1

CHASSY COMPLETE

1

CWD50C1599

 

 

 

 

 

 

 

2

FAN MOTOR

1

ARW6101CB

O

 

 

 

 

 

 

3

CROSS FLOW FAN COMPLETE

1

CWH02C1076

 

 

 

 

 

 

 

4

BEARING ASS’Y

1

CWH64K007

 

 

 

 

 

 

 

5

SCREW - CROSS FLOW FAN

1

CWH551146

 

 

 

 

 

 

 

6

EVAPORATOR CO.

1

CWB30C3074

CWB30C3075

 

 

 

 

 

 

 

7

FLARE NUT (LIQUID)

1

CWT251030

 

 

 

 

 

 

 

8

FLARE NUT (GAS)

1

CWT251031

CWT251032

 

 

 

 

 

 

 

9

CLIP FOR SENSOR

1

CWH32143

 

 

 

 

 

 

 

10

DISCHARGE GRILLE COMPLETE

1

CWE20C3009

 

 

 

 

 

 

 

11

VERTICAL VANE

11

CWE241287

 

 

 

 

 

 

 

12

CONNECTING BAR

1

CWE261152

 

 

 

 

 

 

 

13

CONNECTING BAR

1

CWE261153

 

 

 

 

 

 

 

14

CONNECTING BAR

1

CWE261154

 

 

 

 

 

 

 

15

CONNECTING BAR

1

CWE261155

 

 

 

 

 

 

 

16

FULCRUM

1

CWH621102

 

 

 

 

 

 

 

17

AIR SWING MOTOR

1

CWA981240

O

 

 

 

 

 

 

18

CAP - DRAIN TRAY

1

CWH521096

 

 

 

 

 

 

 

19

HORIZONTAL VANE COMPLETE

1

CWE24C1268

 

 

 

 

 

 

 

20

BACK COVER CHASSIS

1

CWD933019

 

 

 

 

 

 

 

21

CONTROL BOARD CASING

1

CWH102370

 

 

 

 

 

 

 

22

TERMINAL BOARD COMPLETE

1

CWA28C2357

O

 

 

 

 

 

 

23

ELECTRONIC CONTROLLER - MAIN

1

CWA73C3888

CWA73C3889

O

 

 

 

 

 

 

24

ELECTRONIC CONTROLLER - POWER

1

CWA745322

O

 

 

 

 

 

 

25

ELECTRONIC CONTROLLER - INDICATOR & RECEIVER

1

CWA745300

O

 

 

 

 

 

 

26

INDICATOR HOLDER

1

CWD933021

 

 

 

 

 

 

 

27

SENSOR COMPLETE

1

CWA50C2401

O

 

 

 

 

 

 

28

CONTROL BOARD FRONT COVER

1

CWH13C1183

 

 

 

 

 

 

 

29

CONTROL BOARD TOP COVER

1

CWH131350

 

 

 

 

 

 

 

31

REMOTE CONTROL COMPLETE

1

CWA75C3425

O

 

 

 

 

 

 

32

FRONT GRILLE COMPLETE

1

CWE11C4307

O

 

 

 

 

 

 

33

INTAKE GRILLE COMPLETE

1

CWE22C1508

 

 

 

 

 

 

 

34

GRILLE DOOR COMPLETE

1

CWE14C1029

 

 

 

 

 

 

 

35

AIR FILTER

2

CWD001279

 

 

 

 

 

 

 

36

SCREW - FRONT GRILLE

2

XTT4+16CFJ

 

 

 

 

 

 

 

37

CAP - FRONT GRILLE

2

CWH521194

 

 

 

 

 

 

 

38

DRAIN HOSE

1

CWH851173

 

 

 

 

 

 

 

39

INSTALLATION PLATE

1

CWH361097

 

 

 

 

 

 

 

40

BAG COMPLETE - INSTALLATION SCREW

1

CWH82C067

 

 

 

 

 

 

 

45

OPERATING INSTRUCTIONS

1

CWF566888

 

 

 

 

 

 

 

46

INSTALLATION INSTRUCTIONS

1

CWF614037

 

 

 

 

 

 

 

47

INSTALLATION INSTRUCTIONS

1

CWF614038

 

 

 

 

 

 

 

48

INSTALLATION INSTRUCTIONS

1

CWF614039

 

 

 

 

 

 

 

49

INSTALLATION INSTRUCTIONS

1

CWF614040

 

 

 

 

 

 

 

50

INSTALLATION INSTRUCTIONS

1

CWF614041

 

 

 

 

 

 

 

(NOTE)

All parts are supplied from PHAAM, Malaysia (Vendor Code: 00029488).

“O” marked parts are recommended to be kept in stock.

82

Image 82
Contents Table of Contents Exploded View and Replacement Parts List Safety Precautions Page Specifications Model Indoor CS-CE9JKE Outdoor CU-CE9JKEType Propeller Fan Material Motor Type Model Indoor CS-CE9JKE Outdoor CU-CE9JKE Model Indoor CS-CE12JKE Outdoor CU-CE12JKE Cool/Fan M3/min ft3/min Model Indoor CS-CE12JKE Outdoor CU-CE12JKE Features Easy to use remote control Quality ImprovementIndoor Unit Outdoor Unit Remote Control Location of Controls and ComponentsDimensions Indoor UnitOutdoor Unit Refrigeration Cycle Diagram Block Diagram Wiring Connection Diagram Outdoor Unit Electronic Circuit Diagram Outdoor Unit Printed Circuit Board Main Printed Circuit BoardPower Printed Circuit Board Indicator Printed Circuit Board Outdoor Unit Select the Best Location Installation InstructionIndoor/Outdoor Unit Installation Diagram Indoor UnitTo Drill a Hole in the Wall and Install Sleeve of Piping How to Fix Installation PlateIndoor Unit Installation This can be used for left rear piping and bottom piping also Connect the Cable to the Indoor Unit Cutting and Flaring the PipingConnect the Piping Install the Outdoor UnitEvacuation of the Equipment Connect the Cable to the Outdoor Unit Pipe InsulationOperation and Control Basic FunctionAutomatic Operation Indoor Fan Motor OperationFan Operation Airflow Direction Outdoor Fan Motor OperationVertical Airflow Auto Restart Control Timer ControlIndication Panel Protection Control Protection Control For All OperationsLow Pressure Prevention Control Gas Leakage Detection Compressor Overheating Prevention ControlLow Frequency Protection Control Cooling Overload Control Outdoor Air Temperature ControlProtection Control For Cooling & Soft Dry Operation Freeze Prevention ControlProtection Control For Heating Operation Servicing Mode Auto OFF/ON ButtonReset AC Remote Control ButtonReset RC TimerTroubleshooting Guide Refrigeration Cycle SystemLow Pressure High Pressure Breakdown Self Diagnosis Function Self Diagnosis Function Three Digits Alphanumeric CodeError Codes Table Protection control JudgementPower source or compressor lock Self-diagnosis Method 15.4.1. H11 Indoor/Outdoor Abnormal Communication15.4.2. H14 Indoor Intake Air Temperature Sensor Abnormality 15.4.3. H15 Compressor Temperature Sensor Abnormality 15.4.4. H16 Outdoor Current Transformer Open Circuit 15.4.5. H19 Indoor Fan Motor DC Motor Mechanism Locked 15.4.6. H23 Indoor Pipe Temperature Sensor Abnormality 15.4.7. H27 Outdoor Air Temperature Sensor Abnormality 15.4.8. H28 Outdoor Pipe Temperature Sensor Abnormality Malfunction Decision Conditions 15.4.10. H33 Unspecified Voltage between Indoor and Outdoor 15.4.11. H97 Outdoor Fan Motor DC Motor Mechanism Locked 15.4.12. H98 Indoor High Pressure Protection Malfunction Caused 15.4.14. F11 4-way valve Abnormality 15.4.15. F90 Power Factor Correction Protection 15.4.16. F91 Refrigeration Cycle Abnormality Multi Models Only15.4.17. F93 Compressor Rotation Failure 15.4.18. F95 Cooling High Pressure Abnormality 15.4.19. F96 IPM Overheating 15.4.20. F97 Compressor Overheating 15.4.21. F98 Input Over Current Detection 15.4.22. F99 Output Over Current Detection Disassembly and Assembly Instructions To remove front grille To remove power electronic controllerTo remove discharge grille Page Page Outdoor Electronic Controller Removal Procedure Operation Characteristics Technical DataCU-CE9JKE Page Page Page CU-CE12JKE Page Page Page Sensible Capacity Chart CU-CE12JKEExploded View and Replacement Parts List Chassy Complete Outdoor Unit Chassy ASS’Y