Panasonic specifications Specifications, Model Indoor CS-CE9JKE Outdoor CU-CE9JKE

Page 5

2 Specifications

MODEL

 

 

INDOOR

 

CS-CE9JKE

 

 

 

OUTDOOR

 

CU-CE9JKE

 

 

 

 

 

 

 

 

 

 

 

 

 

Performance Test Condition

 

 

EUROVENT

 

 

 

 

 

 

 

 

 

 

Power Supply

 

 

Phase, Hz

 

Single, 50

 

 

 

 

 

 

 

 

 

V

 

230

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min.

Mid.

Max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

0.60

2.60

3.00

 

Capacity

 

 

 

 

 

 

 

 

 

BTU/h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Kcal/h

520

2240

2580

 

 

 

 

 

 

 

 

 

Running Current

 

 

A

2.8

 

 

 

 

 

 

 

 

 

Input Power

 

 

W

125

590

750

 

 

 

 

 

 

Cooling

Annual Consumption

kWh

295

 

 

 

 

 

 

 

 

EER

 

 

W/W

4.80

4.41

4.00

 

 

 

 

 

 

 

 

 

 

 

 

 

Kcal/hW

4.16

3.80

3.44

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Factor

 

 

%

92

 

 

 

 

 

 

 

 

 

 

Indoor Noise (H / L)

 

 

dB-A

 

39 / 25

 

 

 

 

 

 

 

 

 

 

 

Power Level dB

 

55 / 42

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Noise (H / L)

dB-A

 

46 / -

 

 

 

 

 

 

 

Power Level dB

 

61 / -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

0.60

3.60

5.00

 

Capacity

 

 

 

 

 

 

 

 

 

BTU/h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Kcal/h

520

3100

4300

 

 

 

 

 

 

 

 

 

Running Current

 

 

A

3.9

 

 

 

 

 

 

 

 

Heating

Input Power

 

 

W

120

835

1.34k

 

 

 

 

 

 

 

 

COP

 

 

W/W

5.00

4.31

3.73

 

 

 

 

 

 

 

 

 

 

 

 

 

Kcal/hW

4.33

3.71

3.21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Factor

 

 

%

93

 

 

 

 

 

 

 

 

 

 

Indoor Noise (H / L)

 

 

dB-A

 

40 / 27

 

 

 

 

 

 

 

 

 

 

 

Power Level dB

 

56 / 43

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Noise (H / L)

dB-A

 

47 / -

 

 

 

 

 

 

 

Power Level dB

 

62 / -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Temp. : Capacity (kW) / I.Power (W) / COP

 

3.62 / 1.19k / 3.04

 

 

 

 

 

Extr Low Temp. : Capacity (kW) / I.Power (W) / COP

 

3.05 / 1.27k / 2.40

 

 

 

 

 

 

Max Current (A) / Max Input Power (W)

 

 

6.0 / 1.34k

 

 

 

 

 

 

 

 

Starting Current (A)

 

 

 

 

3.9

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

 

Hermetic Motor

 

Compressor

 

 

 

 

 

 

 

Motor Type

 

 

Brushless (4-poles)

 

 

 

 

 

 

 

 

 

 

 

 

Output Power

W

 

750

 

 

 

 

 

 

 

 

 

 

 

Type

 

 

 

 

Cross-flow Fan

 

 

 

 

 

 

 

 

 

 

Material

 

 

 

 

ASG20K1

 

 

 

 

 

 

 

 

 

 

Motor Type

 

 

 

 

Transistor (8-poles)

 

 

 

 

 

 

 

 

 

Fan

Input Power

 

 

W

 

47

 

 

 

 

 

 

 

 

 

Output Power

 

 

W

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor

 

 

Lo

Cool/Fan

rpm

 

750

 

 

 

 

 

 

 

 

 

 

 

Heat

rpm

 

800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Speed

 

Me

Cool/Fan

rpm

 

935

 

 

 

 

 

 

 

 

 

 

Heat

rpm

 

1015

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hi

Cool/Fan

rpm

 

1120

 

 

 

 

 

 

 

 

 

 

 

 

Heat

rpm

 

1230

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Image 5
Contents Table of Contents Exploded View and Replacement Parts List Safety Precautions Page Model Indoor CS-CE9JKE Outdoor CU-CE9JKE SpecificationsType Propeller Fan Material Motor Type Model Indoor CS-CE9JKE Outdoor CU-CE9JKE Model Indoor CS-CE12JKE Outdoor CU-CE12JKE Cool/Fan M3/min ft3/min Model Indoor CS-CE12JKE Outdoor CU-CE12JKE Easy to use remote control Quality Improvement FeaturesLocation of Controls and Components Indoor Unit Outdoor Unit Remote ControlIndoor Unit DimensionsOutdoor Unit Refrigeration Cycle Diagram Block Diagram Wiring Connection Diagram Outdoor Unit Electronic Circuit Diagram Outdoor Unit Main Printed Circuit Board Printed Circuit BoardPower Printed Circuit Board Indicator Printed Circuit Board Outdoor Unit Indoor/Outdoor Unit Installation Diagram Installation InstructionSelect the Best Location Indoor UnitIndoor Unit Installation How to Fix Installation PlateTo Drill a Hole in the Wall and Install Sleeve of Piping This can be used for left rear piping and bottom piping also Cutting and Flaring the Piping Connect the Cable to the Indoor UnitEvacuation of the Equipment Install the Outdoor UnitConnect the Piping Pipe Insulation Connect the Cable to the Outdoor UnitBasic Function Operation and ControlFan Operation Indoor Fan Motor OperationAutomatic Operation Vertical Airflow Outdoor Fan Motor OperationAirflow Direction Indication Panel Timer ControlAuto Restart Control Protection Control For All Operations Protection ControlLow Frequency Protection Control Compressor Overheating Prevention ControlLow Pressure Prevention Control Gas Leakage Detection Protection Control For Cooling & Soft Dry Operation Outdoor Air Temperature ControlCooling Overload Control Freeze Prevention ControlProtection Control For Heating Operation Auto OFF/ON Button Servicing ModeReset RC Remote Control ButtonReset AC TimerRefrigeration Cycle System Troubleshooting GuideLow Pressure High Pressure Self Diagnosis Function Three Digits Alphanumeric Code Breakdown Self Diagnosis FunctionProtection control Judgement Error Codes TablePower source or compressor lock 15.4.1. H11 Indoor/Outdoor Abnormal Communication Self-diagnosis Method15.4.2. H14 Indoor Intake Air Temperature Sensor Abnormality 15.4.3. H15 Compressor Temperature Sensor Abnormality 15.4.4. H16 Outdoor Current Transformer Open Circuit 15.4.5. H19 Indoor Fan Motor DC Motor Mechanism Locked 15.4.6. H23 Indoor Pipe Temperature Sensor Abnormality 15.4.7. H27 Outdoor Air Temperature Sensor Abnormality 15.4.8. H28 Outdoor Pipe Temperature Sensor Abnormality Malfunction Decision Conditions 15.4.10. H33 Unspecified Voltage between Indoor and Outdoor 15.4.11. H97 Outdoor Fan Motor DC Motor Mechanism Locked 15.4.12. H98 Indoor High Pressure Protection Malfunction Caused 15.4.14. F11 4-way valve Abnormality 15.4.15. F90 Power Factor Correction Protection Multi Models Only 15.4.16. F91 Refrigeration Cycle Abnormality15.4.17. F93 Compressor Rotation Failure 15.4.18. F95 Cooling High Pressure Abnormality 15.4.19. F96 IPM Overheating 15.4.20. F97 Compressor Overheating 15.4.21. F98 Input Over Current Detection 15.4.22. F99 Output Over Current Detection To remove front grille To remove power electronic controller Disassembly and Assembly InstructionsTo remove discharge grille Page Page Outdoor Electronic Controller Removal Procedure CU-CE9JKE Technical DataOperation Characteristics Page Page Page CU-CE12JKE Page Page Page CU-CE12JKE Sensible Capacity ChartExploded View and Replacement Parts List Chassy Complete Outdoor Unit Chassy ASS’Y