Panasonic CS-CE9JKE specifications Chassy ASS’Y

Page 84

REF. NO.

PART NAME & DESCRIPTION

QTY.

CU-CE9JKE

CU-CE12JKE

REMARKS

 

 

 

 

 

 

1

CHASSY ASS’Y

1

CWD50K2202

 

 

 

 

 

 

 

2

ANTI-VIBRATION BUSHING

3

CWH50077

 

 

 

 

 

 

 

3

COMPRESSOR

1

5CS110XBD04

O

 

 

 

 

 

 

4

NUT - COMPRESSOR MOUNT

3

CWH56000J

 

 

 

 

 

 

 

5

CRANKCASE HEATER

1

CWA341050

 

 

 

 

 

 

 

6

SOUND PROOF MATERIAL

1

CWG302466

 

 

 

 

 

 

 

7

FAN MOTOR BRACKET

1

CWD541089

 

 

 

 

 

 

 

8

FAN MOTOR

1

ARW44W8P40AC

O

 

 

 

 

 

 

9

SCREW - FAN MOTOR BRACKET

2

CWH551217

 

 

 

 

 

 

 

10

SCREW - FAN MOTOR MOUNT

4

CWH55252J

 

 

 

 

 

 

 

11

PROPELLER FAN ASS’Y

1

CWH03K1014

 

 

 

 

 

 

 

12

NUT - PROPELLER FAN

1

CWH56053J

 

 

 

 

 

 

 

13

CONDENSER CO.

1

CWB32C2874

 

 

 

 

 

 

 

14

TUBE ASSY CO. (CAP./CHK VALVE/RECEIVER)

1

CWT01C5125

CWT01C5126

 

 

 

 

 

 

 

16

HOLDER - COUPLING

1

CWH351023

 

 

 

 

 

 

 

17

3-WAY VALVE (GAS)

1

CWB011434

CWB011523

O

 

 

 

 

 

 

18

4-WAY VALVE

1

CWB001037J

O

 

 

 

 

 

 

19

2-WAY VALVE (LIQUID)

1

CWB021400

O

 

 

 

 

 

 

21

V-COIL CO. (4-WAY VALVE)

1

CWA43C2144J

 

 

 

 

 

 

 

24

SENSOR COMPLETE (AIR & PIPE TEMP.)

1

CWA50C2402

 

 

 

 

 

 

 

25

SENSOR COMPLETE (DISCHARGE TEMP.)

1

CWA50C2512

 

 

 

 

 

 

 

27

TERMINAL BOARD ASS’Y

1

CWA28K1110J

 

 

 

 

 

 

 

29

REACTOR

1

G0C193J00003

 

 

 

 

 

 

 

31

ELECTRONIC CONTROLLER - MAIN

1

CWA73C3898R

CWA73C3899R

 

 

 

 

 

 

 

32

CRANKCASE HEATER

1

CWA341060

 

 

 

 

 

 

 

33

CONTROL BOARD COVER - TOP

1

CWH131264

 

 

 

 

 

 

 

34

SENSOR COMPLETE (COMP. TEMP.)

1

CWA50C2205

 

 

 

 

 

 

 

36

TERMINAL COVER

1

CWH171039A

 

 

 

 

 

 

 

37

NUT - TERMINAL COVER

1

CWH7080300J

 

 

 

 

 

 

 

38

SOUND PROOF BOARD

1

CWH151188

 

 

 

 

 

 

 

39

CABINET SIDE PLATE (RIGHT)

1

CWE04C1212

 

 

 

 

 

 

 

40

CABINET SIDE PLATE (LEFT)

1

CWE041278A

 

 

 

 

 

 

 

41

HANDLE

1

CWE161010

 

 

 

 

 

 

 

42

WIRE NET

1

CWD041111A

 

 

 

 

 

 

 

43

CABINET FRONT PLATE CO.

1

CWE06C1136

 

 

 

 

 

 

 

44

CABINET TOP PLATE

1

CWE031014A

 

 

 

 

 

 

 

45

PLATE - CONTROL BOARD COVER

1

CWH131301

 

 

 

 

 

 

 

46

CONTROL BOARD COVER COMPLETE

1

CWH13C1064

 

 

 

 

 

 

 

50

RECEIVER

1

CWB14011

 

 

 

 

 

 

 

51

STRAINER

1

CWB111004

 

 

 

 

 

 

 

(NOTE)

All parts are supplied from PHAAM, Malaysia (Vendor Code: 00029488).

“O” marked parts are recommended to be kept in stock.

 

[PHAAM] Printed in Malaysia

84

SFYW0905-00

Image 84
Contents Table of Contents Exploded View and Replacement Parts List Safety Precautions Page Specifications Model Indoor CS-CE9JKE Outdoor CU-CE9JKEType Propeller Fan Material Motor Type Model Indoor CS-CE9JKE Outdoor CU-CE9JKE Model Indoor CS-CE12JKE Outdoor CU-CE12JKE Cool/Fan M3/min ft3/min Model Indoor CS-CE12JKE Outdoor CU-CE12JKE Features Easy to use remote control Quality ImprovementIndoor Unit Outdoor Unit Remote Control Location of Controls and ComponentsDimensions Indoor UnitOutdoor Unit Refrigeration Cycle Diagram Block Diagram Wiring Connection Diagram Outdoor Unit Electronic Circuit Diagram Outdoor Unit Printed Circuit Board Main Printed Circuit BoardPower Printed Circuit Board Indicator Printed Circuit Board Outdoor Unit Installation Instruction Indoor/Outdoor Unit Installation DiagramSelect the Best Location Indoor UnitHow to Fix Installation Plate To Drill a Hole in the Wall and Install Sleeve of PipingIndoor Unit Installation This can be used for left rear piping and bottom piping also Connect the Cable to the Indoor Unit Cutting and Flaring the PipingInstall the Outdoor Unit Connect the PipingEvacuation of the Equipment Connect the Cable to the Outdoor Unit Pipe InsulationOperation and Control Basic FunctionIndoor Fan Motor Operation Automatic OperationFan Operation Outdoor Fan Motor Operation Airflow DirectionVertical Airflow Timer Control Auto Restart ControlIndication Panel Protection Control Protection Control For All OperationsCompressor Overheating Prevention Control Low Pressure Prevention Control Gas Leakage DetectionLow Frequency Protection Control Outdoor Air Temperature Control Protection Control For Cooling & Soft Dry OperationCooling Overload Control Freeze Prevention ControlProtection Control For Heating Operation Servicing Mode Auto OFF/ON ButtonRemote Control Button Reset RCReset AC TimerTroubleshooting Guide Refrigeration Cycle SystemLow Pressure High Pressure Breakdown Self Diagnosis Function Self Diagnosis Function Three Digits Alphanumeric CodeError Codes Table Protection control JudgementPower source or compressor lock Self-diagnosis Method 15.4.1. H11 Indoor/Outdoor Abnormal Communication15.4.2. H14 Indoor Intake Air Temperature Sensor Abnormality 15.4.3. H15 Compressor Temperature Sensor Abnormality 15.4.4. H16 Outdoor Current Transformer Open Circuit 15.4.5. H19 Indoor Fan Motor DC Motor Mechanism Locked 15.4.6. H23 Indoor Pipe Temperature Sensor Abnormality 15.4.7. H27 Outdoor Air Temperature Sensor Abnormality 15.4.8. H28 Outdoor Pipe Temperature Sensor Abnormality Malfunction Decision Conditions 15.4.10. H33 Unspecified Voltage between Indoor and Outdoor 15.4.11. H97 Outdoor Fan Motor DC Motor Mechanism Locked 15.4.12. H98 Indoor High Pressure Protection Malfunction Caused 15.4.14. F11 4-way valve Abnormality 15.4.15. F90 Power Factor Correction Protection 15.4.16. F91 Refrigeration Cycle Abnormality Multi Models Only15.4.17. F93 Compressor Rotation Failure 15.4.18. F95 Cooling High Pressure Abnormality 15.4.19. F96 IPM Overheating 15.4.20. F97 Compressor Overheating 15.4.21. F98 Input Over Current Detection 15.4.22. F99 Output Over Current Detection Disassembly and Assembly Instructions To remove front grille To remove power electronic controllerTo remove discharge grille Page Page Outdoor Electronic Controller Removal Procedure Technical Data Operation CharacteristicsCU-CE9JKE Page Page Page CU-CE12JKE Page Page Page Sensible Capacity Chart CU-CE12JKEExploded View and Replacement Parts List Chassy Complete Outdoor Unit Chassy ASS’Y