Chief Manufacturing CM2C40 Interface Board Hardware Information, Dry Contact Closures

Page 24

CM2C40

Installation Instructions

CM2C40 Interface Board Hardware Information

(See figure 31)

Dry Contact Closures

The unit provides dry contact outputs for system feedback, or to control other devices.

To complete circuits to external devices:

7.Connect the common wire from your switch to terminal 7. (See figure 32)

8.Connect the 'up' wire from your switch to terminal 5.

9.Connect the 'down' wire from your switch to terminal 6.

 

Figure 32

 

 

 

J1

Pin 1

Isolated Extend/Retract Input (+)

 

 

Pin 2

Isolated Extend/Retract Input (-)

 

 

Pin 3

Isolated Voltage Sense Input (+)

 

 

Pin 4

Isolated Voltage Sense Input (-)

 

 

Pin 5

24V DC Supply Out (150ma Max.)

 

 

Pin 6

Ground

 

 

Pin 7

RS485 Ref.

 

 

Pin 8

RS485 (+)

 

 

Pin 9

RS485 (-)

 

 

 

 

 

J2

 

 

Pin 1

Not Used

 

 

Pin 2

Not Used

 

 

Pin 3

Not Used

 

 

Pin 4

Not Used

 

 

Pin 5

Move Extend Terminal Input

 

 

Pin 6

Move Retract Terminal Input

 

 

Pin 7

Ground

 

 

Pin 8

Extend Error Input

 

 

Pin 9

Retract Error Input

 

 

Pin 10

Ground

 

 

Pin 11

Extend Limit Out

 

 

Pin 12

Extend Limit Out Return

 

 

Pin 13

Retract Limit Out

 

 

Pin14

Retract Limit Out Return

 

 

24

Image 24
Contents CM2C40 Important Warnings and Cautions Installation Instructions CM2C40 Open-Ended Wrench Power Requirements and Wiring Pre-Installation Configuration and AdjustmentsConfiguring the Mount for the Display Adjusting Faceplate LocationIf more than 2 of faceplate adjustment is required Severe Personal Injury or Damage toCable Installation and Routing CM2C40 Installation Instructions Side Cover Mount Installation Display Installation CM2C40 Installation Instructions Bottom Cover Installation Bottom Cover Location Adjustment Lift Column Bearing Adjustment Normal Operating Mode Remote Control FunctionIR System Code IR-SE15 Programming IR-SE15 Control CodesIR-SC33a Control Features Carrier Frequency 38KHz IR-SC33a ProgrammingSystem Code 6E Connecctions to be made to 9 pin connector as follows Serial CommunicationsError Message Table CM2C40 Hardware Reference Motor Control Hardware InformationCM2C40 Connectors and Switches CM2C40 Interface Board Hardware Information Dry Contact ClosuresExtend Retract with Single Switch Voltage Sense External Power SourceVoltage Sense Internal 24V DC Power Source Extend Error InputRetract Error Input Extend Limit OptionRetract Limit Option Connector and Switch Assignments SW1Ceiling Mounting Holes Door Bracket Troubleshooting +86-755-8996 9226 8996 9236 8996 +86-755-8996