Chief Manufacturing CM2C40 Other Dry Contact Options, Extend Retract with Single Switch

Page 25

Installation Instructions

CM2C40

Other Dry Contact Options

Extend Retract with Single Switch

Pins 1 and 2 on 9 pin Connector. (See figure 31) and (See figure 33)

Figure 33

Voltage Sense External Power Source

Unit extends and stays extended when voltage from an external source is applied across pins 3 and 4 on connector J1. When voltage is removed unit retracts. (See figure 31) and (See figure 34)

Figure 34

Voltage Sense Internal 24V DC Power Source

The 24V DC power supply that is built into the unit can be used to power external devices by using pins 5 and 6 on connector J1.

NOTE: Using this input will force a complete UP/DOWN cycle of the unit. No other inputs, with the exception of error inputs, are available until the cycle has completed. (See figure 31) and (See figure 35)

Figure 35

Extend Error Input

NOTE: Units are shipped with error contacts "Normally Open". To set unit to respond to "Normally Closed" error contacts contact a Chief Technical Support representative by calling 1-800-582-6480, or by visiting www.chiefmfg.com.

When unit receives an Extend error signal during an extend operation, the unit will immediately stop and reverse direction.

(See figure 31) and (See figure 36)

J2

Figure 36

25

Image 25
Contents CM2C40 Important Warnings and Cautions Installation Instructions CM2C40 Open-Ended Wrench Pre-Installation Configuration and Adjustments Power Requirements and WiringConfiguring the Mount for the Display Adjusting Faceplate LocationSevere Personal Injury or Damage to If more than 2 of faceplate adjustment is requiredCable Installation and Routing CM2C40 Installation Instructions Side Cover Mount Installation Display Installation CM2C40 Installation Instructions Bottom Cover Installation Bottom Cover Location Adjustment Lift Column Bearing Adjustment Remote Control Function Normal Operating ModeIR System Code IR-SE15 Control Codes IR-SE15 ProgrammingIR-SC33a Programming IR-SC33a Control Features Carrier Frequency 38KHzSystem Code 6E Serial Communications Connecctions to be made to 9 pin connector as followsError Message Table Motor Control Hardware Information CM2C40 Hardware ReferenceCM2C40 Connectors and Switches Dry Contact Closures CM2C40 Interface Board Hardware InformationVoltage Sense External Power Source Extend Retract with Single SwitchVoltage Sense Internal 24V DC Power Source Extend Error InputExtend Limit Option Retract Error InputRetract Limit Option SW1 Connector and Switch AssignmentsCeiling Mounting Holes Door Bracket Troubleshooting +86-755-8996 +86-755-8996 9226 8996 9236 8996