Emerson IM-106-4050 instruction manual PanelView Installation, Mounting Procedures

Page 34

OxyBalance Oxygen Display and Averaging System

Instruction Manual

IM-106-4050 Original Issue March 2006

PanelView Installation

This equipment is intended for use in clean, dry environments where only non-conductive pollution occurs (except occasionally a temporary conductivity caused by condensation), and with circuits not exceeding Over Voltage Category II (IEC 60664-1).

Disconnect all power before installing or replacing components. Failure to disconnect power may result in electrical shock and/or damage to the equipment.

Mounting Procedures

NOTE

If a communication module is ordered separately, make sure to attach the module to the base unit before panel installation. Refer to the PanelView Plus 600 manual for information on communication modules.

NOTE

Make sure the sealing gasket is properly positioned on the PanelView Plus 600. This gasket forms a compression seal. DO NOT use sealing compounds.

1.Insert the PanelView Plus 600 through the panel cutout on the front of the NEMA 4X protective enclosure front panel. Make sure to align the unit with the center of the panel cutout for adequate gasket sealing.

2.Insert the four mounting levers into the mounting slots on the unit, see Figure 5-3.Slide each lever until the flat side of the lever touches the surface of the panel.

3.Once all levers are in place, slide each lever an additional notch or two until you hear a click.

4.Rotate each lever in the direction indicated until it is in the final latch position.

5.Connect the power wires to the three wire contacts (L1, L2N, and ground) on the PanelView Plus 600. see Figure 5-1.

6.Connect the communication cord to the PanelView Plus 600.

5-4

Image 34
Contents OxyBalance Page Table of Contents Appendix a Section BEssential Instructions OxyBalanceOxygen Display and Averaging System Preface Definitions Symbols Component Checklist Part Numbers Section DescriptionGeneral OxyBalance System Features System OverviewMicroLogix 1200 Programmable Logic Controller Physical DescriptionPanelView Plus ModulesOutput Average Terminals Signal Pass Through TerminalsPower Terminals Failure / Warning TerminalsSpecifications OxyBalance SpecificationsOxyBalance Oxygen Display and Averaging System Section Installation Overview System ConsiderationsWiring Connections Setup MountingInstallation Wiring Schematic Pass-Through Terminals Section Setup OverviewLogin Login Required ScreenLogin Not Required Screen General Scale ValuesTime and Date Setup Time and DateAverage Setup Average1 Average4Current ProbesFault Condition AveragesAll TrendAverage1- Average4 Average # 1-4 failed AlarmAverage # 1-4 warning Probe # 1-8 calibration in progressOxyBalance Oxygen Display and Averaging System OxyBalance Oxygen Display and Averaging System Calibration Section CalibrationOxybalance Averaging SystemOxyBalance Oxygen Display and Averaging System Maintenance and Service Overview Panelview PlusPanelView System Wiring PanelView RemovalMounting Lever Removal PanelView Installation Mounting ProceduresMounting Levers Installation Micrologix 1200 Programmable Controllers PLC RemovalRibbon Cable and Pull Loop PLC Replacement Removal from DIN RailModule Replacement Module RemovalOxyBalance Oxygen Display and Averaging System Troubleshooting Overview Probe FailureOxyBalance Oxygen Display and Averaging System Spare Parts Listing Recommended Spare PartsOxyBalance Oxygen Display and Averaging System Optional Accessories OxyBalance Oxygen Display and Averaging System Appendix a Safety Data Safety Instructionsimportant Belangrijk OxyBalance Oxygen Display Averaging System OxyBalance Oxygen Display and Averaging System Tärkeää OxyBalance Oxygen Display and Averaging System Wichtig Importante Viktig OxyBalance Oxygen Display and Averaging System OxyBalance Oxygen Display Averaging System Viktigt OxyBalance Oxygen Display and Averaging System Appendix B Returning Equipment to the Factory Returning MaterialOxyBalance Oxygen Display and Averaging System Warranty Asia Pacific

IM-106-4050 specifications

The Emerson IM-106-4050 is a cutting-edge instrument designed for industrial measurement and control applications. Known for its reliability and advanced features, this device has gained popularity across various sectors, including oil and gas, chemical processing, and HVAC.

One of the standout features of the IM-106-4050 is its robust design, which makes it suitable for harsh industrial environments. Built with high-quality materials, this instrument can withstand extreme temperatures, humidity, and vibration, ensuring accurate performance in challenging conditions.

The IM-106-4050 integrates state-of-the-art technologies that enhance its functionality. One of its key technologies is the advanced sensor technology that provides precise measurement of process variables such as pressure, temperature, and flow. This accuracy is critical for maintaining optimal process control and ensuring safety in industrial operations.

Another significant characteristic of the IM-106-4050 is its versatility. It supports multiple input types, allowing it to work with various sensors and transmitters. This adaptability makes it an ideal choice for industries with diverse measurement requirements. The device also features a user-friendly interface that simplifies the configuration and operation, enabling technicians to access critical information quickly.

In addition to its measurement capabilities, the IM-106-4050 offers comprehensive communication options. It supports various communication protocols, including HART, MODBUS, and Profibus, facilitating seamless integration with existing control systems. This connectivity is vital for real-time monitoring and reporting, enhancing decision-making processes in industrial settings.

The IM-106-4050 is designed with data logging and advanced diagnostic capabilities. It can store historical data for analysis, enabling users to track trends and make informed adjustments to processes. Furthermore, its diagnostic features help identify potential issues before they escalate, reducing downtime and maintenance costs.

In conclusion, the Emerson IM-106-4050 stands out as a reliable and advanced instrument for measurement and control in industrial applications. With its rugged design, precise sensor technology, versatility, comprehensive communication options, and data logging capabilities, it serves as an invaluable asset for industries striving for efficiency and safety in their processes. As technology continues to evolve, the IM-106-4050 remains a key player in the landscape of industrial instrumentation, meeting the demanding needs of modern applications.