Emerson IM-106-4050 instruction manual Micrologix 1200 Programmable Controllers, PLC Removal

Page 36

Instruction Manual

IM-106-4050 Original Issue March 2006

OxyBalance Oxygen Display and Averaging System

MICROLOGIX 1200 PROGRAMMABLE CONTROLLERS

The MicroLogix 1200 Programmable Controllers consist of one PLC unit and three I/O modules. The PLC mounts horizontally with the expansion I/O modules extending to the right of the controller.

This equipment is intended for use in clean, dry environments where only non-conductive pollution occurs (except occasionally a temporary conductivity caused by condensation), and with circuits not exceeding Over Voltage Category II (IEC 60664-1).

Electrostatic discharge can damage semiconductor devices inside the controller. Do not touch connector pins and other sensitive areas.

PLC Removal

Disconnect all power before installing or replacing components. Failure to disconnect power may result in electrical shock and/or damage to the equipment.

NOTE

Make sure to carefully record the wiring connections and locations before disconnecting. This will aid in the installation of the unit.

1.Tag and disconnect all wiring from the MicroLogix PLC.

2.Remove the cover from the ribbon cable connector on the PLC. Use the pull loop on the connector to disconnect the ribbon cable from the PLC. Do not pull on the ribbon cable. See Figure 5-4.

3.Place a flat-blade screw driver in the DIN rail tab at the bottom of the controller, see Figure 5-5.Holding the PLC, pry downward on the tab until the tab locks in the open position.

4.Repeat step 3 for the second DIN rail tab.

5.Pull the bottom of the PLC out and away from DIN Rail, as shown in Figure 5-6.When the bottom of the PLC is free from the DIN rail, lift up on the PLC until the top is also free of the DIN rail. Remove the PLC from the OxyBalance enclosure.

5-6

Image 36
Contents OxyBalance Page Table of Contents Appendix a Section BOxyBalance Essential InstructionsOxygen Display and Averaging System Preface Definitions Symbols Component Checklist Part Numbers Section DescriptionGeneral OxyBalance System Features System OverviewPhysical Description PanelView PlusMicroLogix 1200 Programmable Logic Controller ModulesSignal Pass Through Terminals Power TerminalsOutput Average Terminals Failure / Warning TerminalsSpecifications OxyBalance SpecificationsOxyBalance Oxygen Display and Averaging System Section Installation Overview System ConsiderationsWiring Connections Setup MountingInstallation Wiring Schematic Pass-Through Terminals Section Setup OverviewLogin Login Required ScreenLogin Not Required Screen General Scale ValuesTime and Date Setup Time and DateAverage Setup Average1 Average4Current ProbesFault Condition AveragesTrend AllAverage1- Average4 Alarm Average # 1-4 warningAverage # 1-4 failed Probe # 1-8 calibration in progressOxyBalance Oxygen Display and Averaging System OxyBalance Oxygen Display and Averaging System Section Calibration OxybalanceCalibration Averaging SystemOxyBalance Oxygen Display and Averaging System Maintenance and Service Overview Panelview PlusPanelView System Wiring PanelView RemovalMounting Lever Removal PanelView Installation Mounting ProceduresMounting Levers Installation Micrologix 1200 Programmable Controllers PLC RemovalRibbon Cable and Pull Loop PLC Replacement Removal from DIN RailModule Replacement Module RemovalOxyBalance Oxygen Display and Averaging System Troubleshooting Overview Probe FailureOxyBalance Oxygen Display and Averaging System Spare Parts Listing Recommended Spare PartsOxyBalance Oxygen Display and Averaging System Optional Accessories OxyBalance Oxygen Display and Averaging System Appendix a Safety Data Safety Instructionsimportant Belangrijk OxyBalance Oxygen Display Averaging System OxyBalance Oxygen Display and Averaging System Tärkeää OxyBalance Oxygen Display and Averaging System Wichtig Importante Viktig OxyBalance Oxygen Display and Averaging System OxyBalance Oxygen Display Averaging System Viktigt OxyBalance Oxygen Display and Averaging System Appendix B Returning Equipment to the Factory Returning MaterialOxyBalance Oxygen Display and Averaging System Warranty Asia Pacific

IM-106-4050 specifications

The Emerson IM-106-4050 is a cutting-edge instrument designed for industrial measurement and control applications. Known for its reliability and advanced features, this device has gained popularity across various sectors, including oil and gas, chemical processing, and HVAC.

One of the standout features of the IM-106-4050 is its robust design, which makes it suitable for harsh industrial environments. Built with high-quality materials, this instrument can withstand extreme temperatures, humidity, and vibration, ensuring accurate performance in challenging conditions.

The IM-106-4050 integrates state-of-the-art technologies that enhance its functionality. One of its key technologies is the advanced sensor technology that provides precise measurement of process variables such as pressure, temperature, and flow. This accuracy is critical for maintaining optimal process control and ensuring safety in industrial operations.

Another significant characteristic of the IM-106-4050 is its versatility. It supports multiple input types, allowing it to work with various sensors and transmitters. This adaptability makes it an ideal choice for industries with diverse measurement requirements. The device also features a user-friendly interface that simplifies the configuration and operation, enabling technicians to access critical information quickly.

In addition to its measurement capabilities, the IM-106-4050 offers comprehensive communication options. It supports various communication protocols, including HART, MODBUS, and Profibus, facilitating seamless integration with existing control systems. This connectivity is vital for real-time monitoring and reporting, enhancing decision-making processes in industrial settings.

The IM-106-4050 is designed with data logging and advanced diagnostic capabilities. It can store historical data for analysis, enabling users to track trends and make informed adjustments to processes. Furthermore, its diagnostic features help identify potential issues before they escalate, reducing downtime and maintenance costs.

In conclusion, the Emerson IM-106-4050 stands out as a reliable and advanced instrument for measurement and control in industrial applications. With its rugged design, precise sensor technology, versatility, comprehensive communication options, and data logging capabilities, it serves as an invaluable asset for industries striving for efficiency and safety in their processes. As technology continues to evolve, the IM-106-4050 remains a key player in the landscape of industrial instrumentation, meeting the demanding needs of modern applications.