4 INSTALL ICU SINK
1.Mount SINK onto the two HANGER STUDS. Hold SINK in place and temporarily install NYLOCK NUT & WASHER on one of the HANGER STUDS to retain SINK.
HANGER STUD
5 INSTALL ELECTRONICS HANGER BRACKET
1.Install the ELECTRONICS HANGER BRACKET onto remaining HANGER STUD. Install NYLOCK NUT & WASHER but do not tighten fully.
2.Remove NYLOCK NUT & WASHER from first HANGER STUD and install other end of ELECTRONICS HANGER BRACKET. Replace NYLOCK NUT & WASHER, tighten both ends. Do not over tighten, chinaware could become damaged.
ELECTRONICS
HANGER BRACKET
NYLOCK NUT AND WASHER
6 COMPLETE WASTE OUTLET CONNECTION
1.Install “P” TRAP. Connect OFFSET TAILPIECE to “P” TRAP. TAILPIECE may have to be cut to fit installation. Use tubing cutter to cut TAILPIECE.
TAILPIECE
WASTE OUTLET
8 CONNECT SPOUT HOSE TO ENCLOSURE
1.Connect SUPPLY NUT (1) from SPOUT assembly to nipple on top of ENCLOSURE (2). Tighten with adjustable wrench to make a water tight connection.
1
7 MOUNT ELECTRONICS BOX
NOTE: Installation with ELECTRONIC BOX only is for cold or tempered water. Use optional MIXING VALVE with ELECTRONIC BOX when Hot and Cold supplies are
ELECTRONIC BOX | ELECTRONIC |
| BOX |
COLD WATER OR | MIXING VALVE |
TEMPERED WATER |
|
(3/8" SUPPLY) | COLD |
HOT |
1.Remove COVER from ELECTRONICS BOX.
2.Place ELECTRONICS BOX onto MOUNTING PLATE. Align BOX with mounting holes. Attach with SCREWS provided.
3.Hang MOUNTING PLATE with ELECTRICAL BOX on
HANGER BRACKET.
ELECTRONIC
BOX
SCREWS
MOUNTING PLATE
2
MIXING VALVE
3 |