American Standard 9118.111, ICU Sink System Install ICU Sink, Install Electronics Hanger Bracket

Page 3

4 INSTALL ICU SINK

1.Mount SINK onto the two HANGER STUDS. Hold SINK in place and temporarily install NYLOCK NUT & WASHER on one of the HANGER STUDS to retain SINK.

HANGER STUD

5 INSTALL ELECTRONICS HANGER BRACKET

1.Install the ELECTRONICS HANGER BRACKET onto remaining HANGER STUD. Install NYLOCK NUT & WASHER but do not tighten fully.

2.Remove NYLOCK NUT & WASHER from first HANGER STUD and install other end of ELECTRONICS HANGER BRACKET. Replace NYLOCK NUT & WASHER, tighten both ends. Do not over tighten, chinaware could become damaged.

ELECTRONICS

HANGER BRACKET

NYLOCK NUT AND WASHER

6 COMPLETE WASTE OUTLET CONNECTION

1.Install “P” TRAP. Connect OFFSET TAILPIECE to “P” TRAP. TAILPIECE may have to be cut to fit installation. Use tubing cutter to cut TAILPIECE.

TAILPIECE

1-1/4" OD

1-1/4" or 1-1/2" OD

WASTE OUTLET

P-TRAP

8 CONNECT SPOUT HOSE TO ENCLOSURE

1.Connect SUPPLY NUT (1) from SPOUT assembly to nipple on top of ENCLOSURE (2). Tighten with adjustable wrench to make a water tight connection.

1

7 MOUNT ELECTRONICS BOX

NOTE: Installation with ELECTRONIC BOX only is for cold or tempered water. Use optional MIXING VALVE with ELECTRONIC BOX when Hot and Cold supplies are roughed-in. See illustration below.

ELECTRONIC BOX

ELECTRONIC

 

BOX

COLD WATER OR

MIXING VALVE

TEMPERED WATER

 

(3/8" SUPPLY)

COLD

HOT

1.Remove COVER from ELECTRONICS BOX.

2.Place ELECTRONICS BOX onto MOUNTING PLATE. Align BOX with mounting holes. Attach with SCREWS provided.

3.Hang MOUNTING PLATE with ELECTRICAL BOX on

HANGER BRACKET.

ELECTRONIC

BOX

SCREWS

MOUNTING PLATE

2

MIXING VALVE

3

7301793-100 Rev. D

Image 3
Contents Model SQ-0-4437 Installation InstructionsInstall Faucet Install Grid Drain and Offset TailpieceROUGH-IN Supplies and Waste Outlet Connect Spout Hose to Enclosure Install ICU SinkInstall Electronics Hanger Bracket Complete Waste Outlet ConnectionConnect Mixing Valve to Water Supplies Install and Connect Mixing Valve Mixing Valve is OptionalElectrical HOOK-UP and Installation InstallationTest Installed Faucet Install Wire HangerCheck ALL Electrical and Plumbing Connections Protective Strip Install Sink ApronRepair Parts AS AMERICA, INC. ONE Year Limited Warranty United StatesCanada