Excell Precision High Precesion Counting Scale manual Quantity CHECK-WEIGHING

Page 20

EXCELL PRECISION CO., LTD.

2-8 QUANTITY CHECK-WEIGHING

If the quantity on the scale is over the preset quantity, the beep will sound and the UNIT WEIGHT

(PER 1000) display will show

-

 

 

 

.

 

 

 

 

 

and flash.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SETTING MAXIMUM LIMIT OF QUANTITY:

 

(1) Press

key (when the scale is loaded or unload).

03

- - - -

 

Stable 3

the latest preset quantity

(2) Key in the maximum limit (Use CE key to make any change).

03

- - - -

 

Stable 3

(3) Press

(The value of maximum quantity)

.

. .

R . . . . . . . key (Use CE key to make any change).

03

- - - -

 

Stable 3

(4) Press

key, the scale will return to the counting mode.

03

.

Stable 3

18

Image 20
Contents ZSME200000007 Page Table of Content FeaturesPreparing to USE the Scale Before Using the ScaleInstructions for USE Features IntroductionExplanation of Display Scale with TWO Weighing UnitsScale with ONE Weighing Unit Quantity 6 digitsIndication Symbol Showing after deduction of package weight TareKEY Function High Precision Counting ScaleStandard Counting Scale PST10. + Power Supply Alternative Power SuppliesPower Consumption LOW Battery WarmingMachine OFF OperationMachine on Scale with ONE Weighing Unit How to preset the unit weightScale with TWO Weighing Units How to recall the preset unit weight Press Key Unit weight of the object to be weighed is unknownCounting Unit weight of the object to be weighed is known Key can recall the latest weight value of 1000 pcsHigh Precision Counting Scale Standard Counting ScaleDeduction of Package Weight Weight of the container is unknown TareWeight of the container is known Pre-Tare 1Setting 0 for the form of pre-tare2Setting 1 for the form of pre-tare Accumulation Put object on the platterSetting Maximum Limit of Quantity Quantity CHECK-WEIGHINGSetting Maximum Limit of Weight CHECK-WEIGHINGBacklight Function Clearing Maximum Limit of Quantity or WeightZero Function Auto Calibration Recall the Orginal Values of CalibrationFunction User Interface SettingSet the appearance Set the form of pre-tare function Set the form Set the action Set the next action Function How to set the speed of sampling and zero range Appendix Specification Table Standard counting scale External resolution 1/6000Capacity Division Minimum Resolution High precision counting scale External resolution 1/15000External resolution 1/30000