2-12 AUTO CALIBRATION

(1) When the displays are zero, press . key then lb/kg key at the same time. Don‘t release your fingers from the keys until the weight display is appeared “ - - - - - ”.

03

.

.

Stable 3

the value of full capacity of the scale

(2)Put the mass (full capacity) on the platter. The scale will be calibrated automatically when it is stable. While the scale is reverting to zero, please take the mass away from the platter.

Press CE can escape from the calibration mode.

FWhen the display appears the value of full capacity, you can directly input the value of the

weight which you want to calibrate. Then, place the mass (calibrated weight) on the platter. The scale will be calibrated automatically when it is stable.

RECALL THE ORGINAL VALUES OF CALIBRATION

If there is something wrong with the auto calibration, press CE then lb/kg at the same time.

Release your finger from the

lb/kg

then

CE

key while the scale is counting down. The scale will

return to the original values of which had been calibrated in factory.

 

 

 

 

 

 

 

 

 

 

 

U.W.

 

 

 

If scale with one weighing unit, please use

 

PST

key to instead of

 

key.

lb/kg

21

Image 23
Contents ZSME200000007 Page Features Table of ContentPreparing to USE the Scale Before Using the ScaleInstructions for USE Introduction FeaturesQuantity 6 digits Explanation of DisplayScale with TWO Weighing Units Scale with ONE Weighing UnitShowing after deduction of package weight Tare Indication SymbolPST KEY FunctionHigh Precision Counting Scale Standard Counting Scale10. + LOW Battery Warming Power SupplyAlternative Power Supplies Power ConsumptionMachine OFF OperationMachine on Scale with ONE Weighing Unit How to preset the unit weightScale with TWO Weighing Units How to recall the preset unit weight Press Key Unit weight of the object to be weighed is unknownCounting Standard Counting Scale Unit weight of the object to be weighed is knownKey can recall the latest weight value of 1000 pcs High Precision Counting ScaleWeight of the container is unknown Tare Deduction of Package Weight1Setting 0 for the form of pre-tare Weight of the container is known Pre-Tare2Setting 1 for the form of pre-tare Put object on the platter AccumulationQuantity CHECK-WEIGHING Setting Maximum Limit of QuantityCHECK-WEIGHING Setting Maximum Limit of WeightBacklight Function Clearing Maximum Limit of Quantity or WeightZero Function Recall the Orginal Values of Calibration Auto CalibrationFunction User Interface SettingSet the appearance Set the form of pre-tare function Set the form Set the action Set the next action Function How to set the speed of sampling and zero range High precision counting scale External resolution 1/15000 Appendix Specification TableStandard counting scale External resolution 1/6000 Capacity Division Minimum ResolutionExternal resolution 1/30000