Excell Precision High Precesion Counting Scale Check-Weighing, Setting Maximum Limit of Weight

Page 21

EXCELL PRECISION CO., LTD.

2-9 CHECK-WEIGHING

If the weight on the platter is over the preset weight, the beep will sound and the UNIT WEIGHT

(PER 1000) display will show and flash.

SETTING MAXIMUM LIMIT OF WEIGHT:

(1) Press

key (when the scale is loaded or unload).

03

- - - -

 

Stable 3

the latest preset weight

(2) Key in the maximum limit (Use CE key to make any change).

03

- - - -

 

Stable 3

The value of maximum weight (100=10.0)

FThe weighing unit and decimal of the maximum weight value which you input should be same as WEIGHT display.

(3) Press

R

key (Use CE key to make any change).

03

- - - -

 

Stable 3

(4) Press

key, the scale will return to the counting mode.

03

.

Stable 3

19

Image 21
Contents ZSME200000007 Page Features Table of ContentBefore Using the Scale Instructions for USEPreparing to USE the Scale Introduction FeaturesScale with TWO Weighing Units Explanation of DisplayScale with ONE Weighing Unit Quantity 6 digitsShowing after deduction of package weight Tare Indication SymbolHigh Precision Counting Scale KEY FunctionStandard Counting Scale PST10. + Alternative Power Supplies Power SupplyPower Consumption LOW Battery WarmingOperation Machine onMachine OFF How to preset the unit weight Scale with TWO Weighing UnitsScale with ONE Weighing Unit How to recall the preset unit weight Unit weight of the object to be weighed is unknown CountingPress Key Key can recall the latest weight value of 1000 pcs Unit weight of the object to be weighed is knownHigh Precision Counting Scale Standard Counting ScaleWeight of the container is unknown Tare Deduction of Package Weight1Setting 0 for the form of pre-tare Weight of the container is known Pre-Tare2Setting 1 for the form of pre-tare Put object on the platter AccumulationQuantity CHECK-WEIGHING Setting Maximum Limit of QuantityCHECK-WEIGHING Setting Maximum Limit of WeightClearing Maximum Limit of Quantity or Weight Zero FunctionBacklight Function Recall the Orginal Values of Calibration Auto CalibrationUser Interface Setting Set the appearanceFunction Set the form of pre-tare function Set the form Set the action Set the next action Function How to set the speed of sampling and zero range Standard counting scale External resolution 1/6000 Appendix Specification TableCapacity Division Minimum Resolution High precision counting scale External resolution 1/15000External resolution 1/30000