Checklist Before Installation

1.Water Pressure - Not less than 20 nor greater than 120 psi (1.4 - 8.4 bar) constant. (See Engineering Specifications, page 13.)

2.Water Temperature - Not less than 40° nor greater than 120°F (6°- 49° C).

(See Engineering Specifications, page 13.)

3.Minimum Service Flow Rate Available To The Appliance - 3 gpm or equal to the backwash flow rate of your particular model. (See Engineering Specifications, page 13.) For filter installa- tion, refer to page 16 to confirm the backwash rates of the specific model.

4.Drain - Drain the appliance to a floor drain, washer drain, or other suitable waste receptor. To prevent back-siphoning, the installer must provide an adequate air gap or a siphon break. See figure 1.

5.Electricity - The transformer supplied is a standard 115 volt, A.C.

6.Water Quality - If your water supply contains sand, sulfur, bacteria, iron bacteria, man- ganese bacteria, tannins, algae, oil, acid, salt, or other unusual substances, additional support equipment must be installed ahead of the WaterMax appliance unless otherwise indicated on the Engineering Specifications, page 13.

NOTES:

3

Image 3
Contents How to Use This Manual How To Get The Maximum Efficiency From Your Appliance Checklist Before Installation Some do Wh en 8z How- To Use The Bypass Valve Installation Guide 8z Start-up Procedure Installation Guide & Start-up Procedure Setting And Using The Appliance Control Setting And Using The Appliance Control Setting And Using The Appliance Control Example Hard. Gr Gal. Remain F4,11gineering Specifications Mode I Setting Chart Mode II Setting Chart BWO Troubleshooting Let is not controlled by a switch Salty water Plugged injector Low water pressure Item no QTY Description Parts -HOOK-UP/COVER AssemblyPART# Description Quanity Parts -BRINE Tank AssemblyParts -Tank/Cabinet Assembly Item no QTY Description Parts Injector Assembly Parts -Bypass Assembly Parts Bypass Assembly Parts -Drive End Cap Assembly Parts Drive End Cap Assembly Parts Brine Valve Housing Assembly Parts Brine Valve Housing Assembly Fill Plug 0-ring Parts Fill Plug AssemblyParts Drain End Cap Assembly Parts Safety Shutoff Parts Brine Valve Elbow Installation Year Limited Warranty Brine Cabinet Data