Hague Quality Water Intl 63BEQ, 63MAQ warranty Setting And Using The Appliance Control

Page 9

Setting And Using The Appliance Control (cont.)

Description Of The Three WaterMax Operating Modes

CAUTION: Be sure the controller is firmly "locked" onto the drive end cap assembly." The four tabs on top of the drive end cap will allow the clips on the bottom of the controller case to lock onto the end cap tabs. (See detail diagram on page 20; fig. 3.)

MODE 1

TIMER MODE: Will regenerate based on frequency. Example: every 2 days or as specified up to 12 days.

Time of regeneration can be set. To regenerate on a specific day or days of the week, set frequency to 00 for WEEKDAY MODE. The display will show: Reg. Days, MTWTF S. To select the day(s), simply use the select and change buttons to eliminate the days not to regenerate. Example: S W F.

MODE 2

PATENTED SAVEMATIC - DEMAND DELAYED: Is based on actual water usage and total capacity of the appliance. Will only regenerate using the amount of salt needed to maintain capacity. Time of regeneration can be set. If total capacity is

depleted before set regeneration time, a forced regeneration will occur. Appliance will regenerate again that night and then go back to the normal setting.

MODE 3

DEMAND IMMEDIATE: Will regenerate based on water usage alone. Regeneration will occur when the capacity limit is reached. Time of regeneration cannot be set.

THE FOLLOWING EXAMPLE takes you through the steps involved for setting the WaterMax SYSTEM CONTROL. If you follow these steps, you will set a WaterMax 62 AMQ for OPERATING MODE 2, DEMAND DELAYED operation. All three OPERATING MODES use similar procedures. Push the SERVICE SETTINGS button to enter SERVICE SETTINGS mode. The display will show: Set Language ENG This parameter is used to set the language that is displayed in the CUSTOMER SETTINGS mode: ENG - English, FRA- French, ESP - Spanish, DEU - German, ITA- Italian.

1.00Push the CHANGE DIGIT button until the correct language is displayed. In this example, set to: Set Language ENG.

2.00Push the NEXT button to step to the next parameter. The display will show: Units ENG

2.00a

Push the CHANGE DIGIT button to toggle English/metric units of measure.

 

For this example, set to: Units ENG.

3.00

Push the NEXT button to step to the next parameter. The display will show: History NO This parameter is used

 

to enter the History file. The History file is used as a record of water readings for future reference. (3.00 - 3.14 is

 

an electronic notepad only and does not affect the operation of the appliance.)

3.00a

Push the CHANGE DIGIT button to toggle between Yes or No. Setting to "Yes" will enter the History file and setting

 

to "No" will bypass the History file. In this example, set to: History Yes

3.01.Push the NEXT button and the display will show Soft. V# 1.01 (Hist). This is information only and cannot be reset. Push the NEXT button to step to the next parameter. The display will show: Inst. Date 000000 (Hist) This parameter is to be set to the installation date of the appliance. There are six digits. The first two are the month. The next two are the day and the final two are the year. This is the first entry in the History file.

3.01a Push and release the CHANGE DIGIT button until the value above the cursor is equal to the number of the desired Month setting.

3.01b Continue using the SELECT and CHANGE buttons until the desired date is displayed. Example: July 24, 2002 = 072402 (Hist)

3.02Push the NEXT button to step to the next parameter. The display will show: # People 000 (Hist) This parameter is used to record the number of people in the household and should match the "# People" setting in the CUSTOMER SETTINGS file.

3.02a Push the SELECT and CHANGE buttons until the desired number of people in the household is reached. In this example, set to: # People 004 (Hist)

3.03Push the NEXT button to step to the next parameter. The display will show: Hard. Or. 000 (Hist) This parameter is used to record the tested Hardness of the water.

3.03a Push the SELECT and CHANGE buttons until the desired hardness number is reached. In this example, set to: Hard. Or. 025 (Hist)

9

Image 9
Contents How to Use This Manual How To Get The Maximum Efficiency From Your Appliance Checklist Before Installation Some do Wh en 8z How- To Use The Bypass Valve Installation Guide 8z Start-up Procedure Installation Guide & Start-up Procedure Setting And Using The Appliance Control Setting And Using The Appliance Control Setting And Using The Appliance Control Example Hard. Gr Gal. Remain F4,11gineering Specifications Mode I Setting Chart Mode II Setting Chart BWO Troubleshooting Let is not controlled by a switch Salty water Plugged injector Low water pressure Item no QTY Description Parts -HOOK-UP/COVER AssemblyPART# Description Quanity Parts -BRINE Tank AssemblyParts -Tank/Cabinet Assembly Item no QTY Description Parts Injector Assembly Parts -Bypass Assembly Parts Bypass Assembly Parts -Drive End Cap Assembly Parts Drive End Cap Assembly Parts Brine Valve Housing Assembly Parts Brine Valve Housing Assembly Fill Plug 0-ring Parts Fill Plug AssemblyParts Drain End Cap Assembly Parts Safety Shutoff Parts Brine Valve Elbow Installation Year Limited Warranty Brine Cabinet Data