Hague Quality Water Intl 63MAQ, 63BEQ warranty Setting And Using The Appliance Control

Page 10

Setting And Using The Appliance Control (cont.)

3.04Push the NEXT button to step to the next Parameter. The display will show: Iron ppm 000 (Hist) This parameter is used to record the tested iron content of the water.

3.04a Push the the SELECT and CHANGE buttons until the desired iron number is reached. In this example, set to: Iron ppm 002 (Hist)

3.05Push the NEXT button to step to the next Parameter. The display will show: Mang. ppm 000 (Hist) This parameter is used to record the tested Manganese content of the water.

3.05a Push the SELECT and CHANGE buttons until the desired manganese number is reached. In this example, set to: Mang. ppm 000 (Hist)

3.06Push the NEXT button to step to the next Parameter. The display will show: Chlor. ppm 000 (Hist) This parameter is used to record the tested chlorine content of the water.

3.06a Push the SELECT and CHANGE buttons until the desired chlorine number is reached. In this example, set to: Chlor. ppm 000 (Hist)

3.07Push the NEXT button to step to the next Parameter. The display will show: Sulfur ppm 000 (Hist) This parameter is used to record the tested sulfur content of the water.

3.07a Push the SELECT and CHANGE buttons until the desired sulfur number is reached. In this example, set to: Sulfur ppm 000 (Hist)

3.08Push the NEXT button to step to the next parameter. The display will show: pH 00.0 (Hist) This parameter is used to record the tested pH of the water.

3.08a Push the SELECT and CHANGE buttons until the desired pH number is reached. In this example, set to: pH 07.0 (Hist)

3.09Push the NEXT button to step to the next parameter. The display will show: Iron Bact YES (Hist) This parameter is used to record the presence of iron bacteria in the water.

3.09a Push the SELECT and CHANGE buttons until the desired word is reached. In this example, set to: Iron Bact. NO (Hist)

3.10Push the NEXT button to step to the next parameter. The display will show: Tot. Regens. 00000 (Hist) This parameter is used to record the total number of regenerations the appliance has gone through and cannot be reset.

Push the NEXT button to step to the next parameter. The display will show: Tot. Gal. 00000000 (Hist)

This parameter is used to record the total number of gallons of water that has passed through the appliance and cannot be reset.

 

Push the NEXT button to step to the next parameter. The display will show: Model # 00AAA (Hist)

 

This parameter is used to record the model number of the appliance.

3.12a

Push the SELECT and CHANGE buttons until the desired model number is reached.

 

In this example, set to: Model # 62AMQ (Hist)

 

Push the NEXT button to the next parameter. The display will show: Save History YES

 

This parameter, if set to YES, will save the current information you have just entered. If set to NO, it will leave the

 

History file as previously defined.

3.14.

Push the CHANGE DIGIT button to toggle between Yes or No. In this example, set to: Save History YES

4.00Push the NEXT button to step to the next parameter. The display will show: Tot. Regens. 00000

This parameter displays the number of regenerations the appliance has gone through since the last time the SERVICE SETTINGS mode was entered. This parameter is reset to 00000 after exiting the SERVICE SETTINGS mode. Push the NEXT button to step to the next parameter. The display will show: Tot. Gal. 00000000

This parameter displays the Total Gallons the appliance has gone through since the last time the SERVICE SETTINGS mode was entered. This parameter is reset to 00000000 after exiting the SERVICE SETTINGS mode.

5.00Push the NEXT button to step to the next parameter. The display will show: Mode 2 The "Mode #" is the number of the OPERATING MODE for which the system control is set.

5.00a Push the CHANGE DIGIT button to change the value of "Mode #" until it reads 2 (for this example.)

10

Image 10
Contents How to Use This Manual How To Get The Maximum Efficiency From Your Appliance Checklist Before Installation Some do Wh en 8z How- To Use The Bypass Valve Installation Guide 8z Start-up Procedure Installation Guide & Start-up Procedure Setting And Using The Appliance Control Setting And Using The Appliance Control Setting And Using The Appliance Control Example Hard. Gr Gal. Remain F4,11gineering Specifications Mode I Setting Chart Mode II Setting Chart BWO Troubleshooting Let is not controlled by a switch Salty water Plugged injector Low water pressure Parts -HOOK-UP/COVER Assembly Item no QTY DescriptionParts -BRINE Tank Assembly PART# Description QuanityParts -Tank/Cabinet Assembly Item no QTY Description Parts Injector Assembly Parts -Bypass Assembly Parts Bypass Assembly Parts -Drive End Cap Assembly Parts Drive End Cap Assembly Parts Brine Valve Housing Assembly Parts Brine Valve Housing Assembly Parts Fill Plug Assembly Fill Plug 0-ringParts Drain End Cap Assembly Parts Safety Shutoff Parts Brine Valve Elbow Installation Year Limited Warranty Brine Cabinet Data