Panasonic MCCG917 manuel dutilisation Using Tools, Attachments on Handle

Page 26

Using Tools

Lock

Button

Bouton

de blocage Botón

del bloqueo

Upper Wand

Tube supérieur

Tubo superior

Handle

Poignée

Mango

Handle Quick Release

Bouton de dégagement rapide de la poignée Soltar Rápida

CAUTION

DO NOT attach or remove handle or wands while vacuum cleaner is ON. This could cause sparking and damage the electrical contacts.

ATTACHMENTS ON HANDLE

If the POWER NOZZLE is attached, turn vacuum cleaner off before removing handle from wands.

Press lock button, then pull to remove handle from wand.

Slide attachments firmly on handle as needed (See page 30).

ATTACHMENTS ON WANDS

Wand Quick

Release Pedal

Pédale de dégagement du tube

Pedal de liberación rápida del tubo

If the POWER NOZZLE is attached, turn vacuum cleaner off before removing plug from wands.

To remove wands from POWER NOZZLE, lock wands in upright position.

Press wand quick release pedal with foot and pull the wands straight up out of POWER NOZZLE.

Put attachments on wands as needed (See page 30).

- 26 -

Image 26
Contents Vacuum Cleaner Household Operating InstructionsTable of Contents Table des matières Tabla de contenidoConsumer Information Avertissement Advertencia Cuidado Important Safety Instructions Avertissement Avertencia Parts Identification Power NozzlePower Nozzle Canister RecepticuloTools HoseTuyau HerramientasFeature Chart Tableau des caractéristiquesAssembly HoodCubierta MontajeAspiridora Hose Latch Tab Mango Pour enleverTool Storage Air Turbine and CaddyAlmacenaje de herramientas Air Turbine y BandejaTo Operate Vacuum Cleaner Power CordCordón eléctrico CuidadoPara operar la aspiridora Pour réenroulerSelect a switch position on handle On-Off SwitchTelescopic Wand Adjustments Control On-Off Ajustes del tubo telescópicoHandle Adjustments Suggested Pile Height SettingsAjustes del mango De la alfombraUsing Tools Attachments on HandleCuidado Uso de herramientasUsing Tools Nota Siempre limpie las herramientas antes de usarlas Overload Protector FeaturesVacuuming Tips Protector contra sobrecargas CaracterísticasSugerencias para aspirar Suction Control Power Nozzle StorageHose Swivel Tapa y almacenamiento para Dispositivo giratorio de la mangueraControl de aspiración Edge Cleaner Thermal ProtectorLimpiador de orillas Protector termalRoutine Care of Vacuum Cleaner Entretien de l’aspirateur Cambio de bolsaMotor Safety Filter Changing Do not operate the vacuum cleaner without filterAvertissement Cambio del filtroExhaust filter cartridge must be replaced when dirty Exhaust Filter ChangingFiltre D’ÉCHAPPEMENT Cambio del filtro de escapePower Nozzle Care Cleaning Exterior and ToolsCuidado de la Power Nozzle Limpieza del exterior y de los herramientasRemoving Belt Agitator AssemblyLift agitator assembly out Remove worn belt Tilt cover forward from back until front snaps freeEnsamble del agitador Sacando la correaReplacing Belt Replace agitator cover Line up front of cover and baseCambio de la correa Brush Servicing Electrical Shock Or Personal Injury HazardCuidado del cepillo Pour Vérifier LES BrossesReplacing Headlight Bulb Removing ClogsRemplacement de l’ampoule de la Lampe Quitando los residuos de basura en Los conductosBefore Requesting Service Problem Possible Cause Possible SolutionGuide de dépannage Antes de pedir servicio Product or Part Name Parts Labor Carry-In or Mail in ServiceLimited Warranty Limits And Exclusions Customer Services Directory United States and Puerto Rico For hearing or speech impaired TTY users, TTYVacuum Cleaner Exchange ProgramProgramme D’ÉCHANGE AspirateursLimites y exclusiones de la Garantía Limitada Producto o Nombre de la parte Partes Mano de obraLlevar al centro de atención o Servicio por correo Para usuarios TTY con problemas de audición y habla Compra de Accesorios Estados Unidos y Puerto RicoPage Page Page Cuando necesita servicio

MCCG917 specifications

The Panasonic MCCG917 is an advanced air conditioning unit designed for modern residential and commercial spaces. With a focus on performance, efficiency, and user convenience, this model stands out in the competitive HVAC market. One of its key features is the inverter technology, which allows the unit to adjust its cooling output based on the current temperature, ensuring optimal comfort while minimizing energy consumption. This results in more stable indoor climates and reduced utility bills, making it an economical choice for users.

The MCCG917 is equipped with a high-efficiency compressor that enhances its cooling performance. This compressor operates quietly, contributing to the overall peaceful environment of the space. Additionally, the unit has a high Seasonal Energy Efficiency Ratio (SEER) rating, which is an essential measure of its energy efficiency over a cooling season. This high rating signifies that the MCCG917 not only cools effectively but does so while maintaining a lower energy footprint compared to traditional units.

Another notable feature is the advanced air filtration system. This system uses a multi-stage filtration process to remove dust, allergens, and microorganisms from the indoor air. This is particularly beneficial for individuals with allergies or respiratory issues, as it promotes a healthier living environment. The unit also includes a deodorizing filter that helps neutralize unpleasant odors, ensuring that the air remains fresh.

User convenience is enhanced through a user-friendly remote control and smart integration capabilities. The MCCG917 can be controlled via a mobile application, allowing users to adjust settings from anywhere within the home or office. This feature is particularly useful for programming cooling schedules, monitoring energy usage, and receiving maintenance alerts.

The design of the Panasonic MCCG917 is sleek and modern, allowing it to blend seamlessly with various interior decors. It is also built to withstand the rigors of daily use, with durable materials and components ensuring longevity. This unit provides not just cooling, but a comprehensive solution for indoor air comfort, making it an ideal choice for consumers seeking efficiency and reliability in their HVAC systems.