AMX RE-DM6, RE-DM4 manual Set Curve, Curve Status, Set Low End, Low End Status

Page 48

AMX RADIA Lighting Programming

Set Curve

This function sets the specified dimmer(s) to follow the specified curve.

Set Curve

String:

<dimmer>/<curve>

 

 

 

 

Response:

<dimmer> CURVE <curve>

 

 

 

 

Examples:

SEND_STRING Radia,"'1/1',13"

 

Set dimmer 1 to curve 1

 

 

 

 

 

Response: "12,'1 CURVE 1',13,10,'?'"

 

 

 

 

 

SEND_STRING Radia,"'1-4/N',13"

 

Set dimmers 1-4 to curve N

 

 

 

 

 

Response: "12,'GROUP CURVE N',13,10,'?'"

 

 

 

 

 

SEND_STRING Radia,"'A/3',13"

 

Set all dimmers to curve 3

 

 

 

 

 

Response: "12,'ALL CURVE 3',13,10,'?'"

 

 

 

 

 

Curve Status

This function returns the curve assigned to each dimmer.

Curve Status

String:

[<pack>]C

 

 

 

Response:

P<pack>:<curve1>,<curve2>,<curve3>,<curve4>,<curve5>,<curve6>

 

 

 

Example:

SEND_STRING Radia,"'C',13"

Request current curve settings

 

 

 

 

Response: "12,'P01:1,1,1,1,N,N',13,10,'?'"

 

 

 

 

If <pack> is specified, it must be 1.

See Appendix A: AMX Lighting Curves section on page 49 for more information.

Set Low End

This function sets the minimum on percentage for the specified dimmer (i.e. a level of 0 will still be off).

For example, if the low end is set to 10, then any request for a level between 1-10 will result in the output level being 10, a request for 0 will be 0, and a request for a level between 11-100 will result in the outputting of that level.

This function is used to prevent certain loads from dimming below the dimmer’s ability.

Set Low End

String:

<dimmer>LE<percent>

 

 

 

 

Response:

MINIMUM LEVEL IS: <percent>

 

 

 

 

Example:

SEND_STRING Radia,"'2LE20',13"

Set minimum level to 20%

 

 

 

 

Response: "12,'MINIMUM LEVEL IS: 020',13,10,'?'"

 

 

 

Low End Status

This function returns the low end settings assigned to each dimmer.

Low End Status

String:

[<pack>]LE?

 

 

 

Response:

P<pack>:<percnt1>,<percnt 2>,<percnt 3>,<percnt 4>,<percnt 5>,<percnt 6>

 

 

 

Example:

SEND_STRING Radia,"'LE?',13"

Request current low end settings

 

 

 

 

Response: "12,'P01:000,005,000,000,005,000',13,10,'?'"

 

 

 

If <pack> is specified, it must be 1.

40

RE-DM4 and RE-DM6 RADIA Eclipse Dimmer Modules

Image 48
Contents Radia Eclipse Dimmer Modules AMX Limited Warranty and Disclaimer Page Page Table of Contents Radia Lighting System Configuration Pages Initial Level Status Reporting Appendix a AMX Lighting Curves Overview Radia Eclipse RE-DM4 Dimmer ModuleRE-DM4 Specifications RE-DM4 SpecificationsDimmed Switched Suggested LoadsRE-DM4 4-pin module connector male Line-In ConnectionsRE-DM4 Lighting Application Drawings Lighting Application for the RE-DM4, Example aRadia Eclipse RE-DM6 Dimmer Module RE-DM6 6-channel Integrated Dimmer ModuleRE-DM6 Specifications Suggested Installation LoadsRE-DM6 Specifications Line-In Connections for the RE-DM6 RE-DM6 Lighting Application Drawings Lighting Application for the RE-DM6, Method aFeatures ApplicationsAMX Lighting Control Equipment AMX Lighting Control EquipmentDimmer Accessories Integrated dimmer control modulesDimmer modules Wiring Considerations Power considerationsSpace Requirements Conduit Knockout locations RDA-ENC2 used as exampleRDA Enclosure Dimensions RDA-ENC2, -ENC4, and -ENC6 enclosure and dimensionsRDA-ENC6B and RDA-ENC12B enclosures and dimensions Mounting AMX Lighting Enclosures Distance a to BConnecting High-Voltage, Single-Phase Input Power and Loads High-Voltage ConnectionsRDA-ENC6B 120 VAC Single Phase Line Input RDA-ENC6B 120/240 VAC Line Input Single PhaseConnecting High-Voltage Input Power and Loads RDA-ENC6B 120/208 VAC line input three phase RDA-ENC6B 120/208 VAC three-phase 4 W + G wiring diagramRDA-ENC6B Three Phase Line Input Connector Reference RDC-PFC Power Distribution And Line Input ReferencesInstalling RDM Modules Into an RDA Enclosure Enclosure module mounting slots and mounting screw holesGreen LED Status Indicator Low-Voltage ConnectionsModule Connections Red LED Status Indicators RE-DM4 only Configuring and connecting multiple controllersConfiguring and Connecting AxLink SW1 DIP Switch Setting Values for AxLinkValue External power Connecting Dry ClosuresDry Closures Failsafe InputDefault Settings Default Low-End SettingsDefault preset time values Default PresetsRadia Lighting System Configuration Pages Lighting System LinkRadia Configuration Manager Main Lighting SystemDevice Configuration Device ConfigurationPresets section Preset Configuration Radia Lighting System Configuration Pages AMX Radia Lighting Programming SoftwarePresets Defined vs. Undefined Levels Preset StatusPreset # Lighting Systems Overview Sample AMX Lighting controller and internal componentsProgramming Commands Control Curves and Low-End SettingsDefault Low-end Default Ramp TimeDefault Ramp Time LevelsAMX Lighting Channel Commands ChannelsSENDSTRINGs Protocol ConventionsRamp Dimmers Up Ramp Dimmers DownRamp Dimmers Up Ramp Dimmers DownRamp Active Preset Up Ramp Active Preset DownStop Ramping Dimmer Stop Ramping Preset Recall PresetRecord Preset Level StatusSet Curve Curve StatusSet Low End Low End StatusReboot Set Default Level TimeSet Default Preset Time Dimmer StatusSet Default Ramp Time Ramp To LevelUndefine Dimmer Phase Query Factory DefaultVersion Query SENDCOMMANDs Ramp Preset Up NEWSendcommand Protocol Conventions Ramp Preset UpRamp Preset Down NEW Stop Ramping Preset NEWRamp Preset Down Reboot NEW Curve Status NEWSet Low End NEW Low End Status NEWUndefine Dimmer NEW Phase Query NEW Sendcommand Radia,?YAppendix a AMX Lighting Curves Basic dimming curve Curve Configuration CurvesCurves Standard Dimming Curve Load Type CurvesCurve 1 Voltage Output in 240V AC Curve 1 with Low End Setting @ 5%, 10%, and 20% Volts RMS Economical Dimming Curve10VDC Curve Curve 2 at 240 VACCurve 3 at 120 VAC 12VDC Curve Curve 4 Voltage output in Volts RMSLutron FDB Curve Curve 4 Voltage output in volts DCCurve 5 at 240 VAC Advance Mark VII Curve Curve 6 Voltage output in Volts RMS12% Roll Off Curve 6 Voltage output in volts DCCurve 7 Voltage output in Volts RMS 19% Roll Off Curve 8 at 120 VAC33% Roll Off Curve 8 Voltage output in volts DCCurve 9 Voltage output in Volts RMS Curve #1 a Curve a at 120 VACLog-Curve #1 B Curve a Voltage output in volts DCCurve B Voltage output in Volts RMS Log-Curve #2 C Curve C at 120 VACCurve #2 D Curve C Voltage output in Volts DC10% Off Curve N Curve D Voltage output in Volts RMSAlways OFF Curve O Curve N at 240 VACAlways on Curve F Curve O at 240 VACCurve F at 240 VAC Curve R at 120 VAC Curves 5 & B on the Radia Eclipse RE-DM6 at 120 VAC Curves a & D at 120 VAC Page Software Issues Using Pass modeTesting AMX Lighting features Testing procedures for AMX Lighting featuresHardware Issues Troubleshooting hardwareHardware Checklist To check thisPage Increase Your Revenue through education + knowledge
Related manuals
Manual 2 pages 38.75 Kb Manual 2 pages 7.17 Kb

RE-DM4, RE-DM6 specifications

The AMX RE-DM4 is a cutting-edge solution in the realm of digital media management, designed to cater to the complexities of modern broadcasting environments. This advanced device aims to streamline workflows, enhance media asset management, and ensure optimal media delivery across various platforms.

One of the standout features of the AMX RE-DM4 is its robust interface, which allows users to interact with the system intuitively. The device incorporates a user-friendly GUI that enables operators to manage media assets effortlessly. The interface supports drag-and-drop functionalities, which greatly simplifies the process of uploading, organizing, and retrieving digital content.

The AMX RE-DM4 also boasts innovative multimedia processing capabilities, allowing it to handle high-resolution video formats with ease. The device supports a range of codecs, ensuring compatibility with the latest video and audio standards. This versatility is crucial for broadcasters who frequently work with diverse media types and formats.

Furthermore, the AMX RE-DM4 features advanced metadata tagging and search functionalities. This technology empowers users to tag media assets with critical information, enabling quick retrieval and efficient categorization. The integrated search engine is designed to facilitate instant searches, thereby reducing downtime and improving overall productivity.

Another notable characteristic of the AMX RE-DM4 is its scalability. The system is designed to grow alongside evolving media requirements, making it an ideal choice for both small studios and large broadcasting networks. With modular components and expandable storage options, users can easily upgrade their systems as their needs change.

In terms of connectivity, the AMX RE-DM4 includes multiple input and output options, ensuring seamless integration with existing studio equipment and networks. It supports various protocols, which enhances compatibility with other devices and allows for more fluid media workflows.

Security is a crucial aspect of digital media management, and the AMX RE-DM4 addresses this by incorporating robust encryption and access control features. Users can set permissions for different team members, safeguarding sensitive content while still allowing collaborative work environments.

In conclusion, the AMX RE-DM4 emerges as a powerful tool for media professionals, integrating state-of-the-art technologies and features that enhance efficiency and productivity. Its intuitive interface, multimedia processing capabilities, advanced search options, scalability, and robust security measures make it a valuable asset in the fast-paced world of digital media management. This device exemplifies a forward-thinking approach to media handling, positioning itself as a leader in the industry.